Microleakage in Class II composite restorations with margins below the CEJ: In vitro evaluation of different restorative techniques

被引:39
|
作者
Poggio, Claudio [1 ]
Chiesa, Marco [1 ]
Scribante, Andrea [2 ]
Mekler, Jenia [1 ]
Colombo, Marco [1 ]
机构
[1] Univ Pavia, Dept Operat Dent, Policlin San Matteo, I-27100 Pavia, Italy
[2] Univ Pavia, Dept Orthodont, Policlin San Matteo, I-27100 Pavia, Italy
来源
关键词
Microleakage; Class II composite restorations; CEJ; CAVITIES; LEAKAGE;
D O I
10.4317/medoral.18344
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this in vitro study was to evaluate the microleakage in "deep" Class II composite restorations with gingival cavosurface margin below the CEJ (cemento-enamel junction) and restored with different techniques. Study Design: Fifty human teeth were used. In each tooth two standardized Class II slot cavities (on mesial and on distal surfaces) were prepared: the buccolingual extension of the cavities was 4 mm; the gingival wall was located in dentin/cementum (2 mm beyond the CEJ). The prepared teeth were randomly assigned to 5 experimental groups (of 10 specimens and 20 cavities each) and restored. Group 1: Filtek TM Supreme XTE Flowable (3MESPE) + Universal Filtek Supreme XTE (3MESPE), Group 2: GrandioSO Heavy Flow (Voco) + GrandioSo (Voco), Group 3: SDR (TM) (Dentsply Caulk) + Esthet-X (R) HD (Dentsply Caulk), Group 4: SonicFill (Kerr), Group 5: Grandio (Voco). After thermocycling, the specimens were immersed in a 0.5% basic fuchsine dye solution and incubated at 37 degrees C for 24 hours. The teeth were subsequently sectioned mesiodistally. All specimens were examined at 25x in a stereomicroscope and standardized digital images were obtained. Dye penetration was measured from gingival margins. Results: The results demonstrated no significant leakage differences between Group 4 and Group 5, that both showed significantly higher frequency distribution of Score 0. Group 2 and Group 3 showed a significant prevalence of Score 1, whereas Group 1 showed significantly higher frequency of Score 2. Conclusions: None of the restorative techniques tested completely eliminated microleakage dye penetration in dentin margins; marginal adaptation in Class II composite restorations with gingival wall below the CEJ varied in both substrates and from different restorative techniques used.
引用
收藏
页码:E793 / E798
页数:6
相关论文
共 50 条
  • [41] Influence of different restorative techniques on microleakage in class II cavities with gingival wall in cementum
    Demarco, FF
    Ramos, OLV
    Mota, CS
    Formolo, E
    Justino, LM
    OPERATIVE DENTISTRY, 2001, 26 (03) : 253 - 259
  • [42] In vivo and in vitro evaluation of class II composite resin restorations with different matrix systems
    Cenci, MS
    Lund, RG
    Pereira, CL
    de Carvalho, RM
    Demarco, FF
    JOURNAL OF ADHESIVE DENTISTRY, 2006, 8 (02): : 127 - 132
  • [43] Influence of the bulk fill restorative technique on microleakage and microtensile of class II restorations
    Koyuturk, Alp Erdin
    Tokay, Ugur
    Sari, M. Erhan
    Ozmen, Bilal
    Cortcu, Murat
    Acar, Hamdi
    Ulker, Mustafa
    PEDIATRIC DENTAL JOURNAL, 2014, 24 (03) : 148 - 152
  • [44] PERMEABILITY AND MICROLEAKAGE OF CLASS-II RESIN COMPOSITE RESTORATIONS
    PRATI, C
    TAO, L
    SIMPSON, M
    PASHLEY, DH
    JOURNAL OF DENTISTRY, 1994, 22 (01) : 49 - 56
  • [45] Effect of accelerated restorative techniques on the microleakage of Class II composites
    Uctasli, S
    Shortall, AC
    Burke, FJT
    AMERICAN JOURNAL OF DENTISTRY, 2002, 15 (03): : 153 - 158
  • [46] In vitro microleakage survey using different restorative materials in class II preparations.
    Hiromoto, J
    Saravia, M
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1272 - 1272
  • [47] Factors associated with microleakage in Class II resin composite restorations
    Idriss, S.
    Abduljabbar, T.
    Habib, C.
    Omar, R.
    OPERATIVE DENTISTRY, 2007, 32 (01) : 60 - 66
  • [48] Effect of Class II cavity configuration on microleakage of composite restorations
    Burmann, PA
    Cardoso, PEC
    Soares, LF
    Guimaräes, M
    Marchezan, M
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1034 - 1034
  • [49] Microleakage in class II restorations using a new posterior composite
    Hurley, E
    Aboushala, A
    Perry, R
    Kugel, G
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 692 - 692
  • [50] Microleakage of Class II box-type composite restorations
    Opdam, NJM
    Roeters, JJM
    Burgersdijk, RCW
    AMERICAN JOURNAL OF DENTISTRY, 1998, 11 (04): : 160 - 164