Dosimetric comparison of two 90Sr/90Y sources for intravascular brachytherapy:: an EGSnrc Monte Carlo calculation

被引:8
|
作者
Wang, RQ [1 ]
Li, XA [1 ]
机构
[1] Univ Maryland, Dept Radiat Oncol, Baltimore, MD 21201 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 23期
关键词
Data reduction - Monte Carlo methods;
D O I
10.1088/0031-9155/47/23/311
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new Sr-90/Y-90 catheter-based system, the Beta-Cath(TM) 3.5F system, was recently introduced into the clinic for intravascular brachytherapy. This new system has a smaller diameter of delivery catheter (3.5 French) compared to the original Beta-Cath(TM) system (5 French catheter). The new source/seed (3.5 F source) has a different design from the original (5F) source. In this paper, we report the EGSnrc Monte Carlo results of two-dimensional dose rate distributions in water as well as the TG-60 dose parameters for the new 3.5F source and the original 5F source. A complete set of the dosimetric data for each individual seed is tabulated. A detailed dosimetric comparison was carried out for the two sources. The comparison shows that differences between the two sources are less than 5% in the region of interest for intravascular brachytherapy. Higher differences (up to 10%) are seen in the near-source region, which is mainly inside the delivery catheter. Based on the present calculation and comparison, we conclude that the new Beta-Cath(TM) 3.517 system is dosimetrically equivalent to the original Beta-Cath(TM) (5F) system. Therefore, clinical dosimetry and the practice of using both the systems can be treated similarly.
引用
收藏
页码:4259 / 4269
页数:11
相关论文
共 50 条
  • [31] Validation of an extraction paper chromatography (EPC) technique for estimation of trace levels of 90Sr in 90Y solutions obtained from 90Sr/90Y generator systems
    Usha Pandey
    Yogendra Kumar
    Ashutosh Dash
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 300 : 355 - 360
  • [32] Dose Calculation in the Water Phantom for 90Sr/90Y Beta Particles Using MCNP Code
    Mowlavi, Ali Asghar
    Binesh, Alireza
    Rejaei, Mohammad
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2028 - +
  • [33] 90Sr/90Y敷贴治疗痤疮的护理配合
    贾芸玲
    孙杰
    王兴刚
    中国美容医学, 2012, 21 (07) : 1249 - 1250
  • [34] Selective permeation of 90Y from a mixture of 90Y/90Sr through diglycolamide impregnated supported liquid membranes
    Kumar, Rohit
    Ansari, S. A.
    Kandwal, Pankaj
    Mohapatra, P. K.
    APPLIED RADIATION AND ISOTOPES, 2021, 170
  • [35] CHROMATOGRAFICKE ODDELOVANIE RADIOCHEMICKY CISTEHO 90Y OD MATERSKEHO 90SR
    MACASEK, F
    CECH, R
    CHEMICKE ZVESTI, 1965, 19 (02): : 107 - &
  • [36] Development of 90Sr/90Y (β) surface applicators by powder metallurgical technology
    Cai, Shanyu
    Sun, Yuhua
    Gao, Wanshan
    Wei, Barhong
    Journal of Radioanalytical and Nuclear Chemistry, 1996, 205 (01): : 113 - 120
  • [37] TID testing of plastic encapsulated microcircuits with 90Sr/90Y source
    Thuesen, GG
    Jorgensen, JL
    Guldager, PB
    PROCEEDINGS OF THE 7TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS, 2004, 536 : 127 - 129
  • [38] Fast determination of 90Sr/90Y activity in milk by Cherenkov counting
    Tsroya, S.
    Dolgin, B.
    German, U.
    Pelled, O.
    Alfassi, Z. B.
    APPLIED RADIATION AND ISOTOPES, 2013, 82 : 332 - 339
  • [39] Sorption of 90Sr and 90Y with stable and metastable modifications of calcium carbonate
    Znamenskaya I.V.
    Berdonosova D.G.
    Berdonosov S.S.
    Sapozhnikov Yu.A.
    Radiochemistry, 2007, 49 (1) : 72 - 75
  • [40] The use of liquid scintillation spectrometry for the determination of radionuclidic purity of 90Y from a radiochemical 90Y/90Sr generator
    Vanura, P
    Jedináková-Krizová, V
    Vobecky, M
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 267 (02) : 501 - 503