Quantification of the Trabecular Bone Volume Fraction with Dual Energy Quantitative CT to Calculate Patient-Specific Radionuclide S Values for Bone Marrow Dosimetry

被引:0
|
作者
Ramirez, M. Salas [1 ]
Tran-Gia, J. [1 ]
Gbureck, U. [1 ]
Kosmala, A. [1 ]
Lassmann, M. [1 ]
机构
[1] Univ Wurzburg, Wurzburg, Germany
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OP-344
引用
收藏
页码:S135 / S136
页数:2
相关论文
共 41 条
  • [21] Dual-energy CT of the bone marrow in multiple myeloma: diagnostic accuracy for quantitative differentiation of infiltration patterns
    Kosmala, Aleksander
    Weng, Andreas Max
    Krauss, Bernhard
    Knop, Stefan
    Bley, Thorsten Alexander
    Petritsch, Bernhard
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5083 - 5090
  • [22] Electron absorbed fractions of energy and S-values in an adult human skeleton based on μCT images of trabecular bone
    Kramer, R.
    Richardson, R. B.
    Cassola, V. F.
    Vieira, J. W.
    Khoury, H. J.
    de O Lira, C. A. B.
    Brown, K. Robson
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06): : 1803 - 1836
  • [23] Model for Computing Patient-Specific Active Marrow Dose Accounting for Variations in Marrow Cellularity and Bone Volume Fractions in Y-90 Zevalin Radioimmunotherapy
    Wilderman, S. J.
    Roberson, P. L.
    Dewaraja, Y. K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S173 - S174
  • [24] FATTY REPLACEMENT OF SPINAL BONE-MARROW DUE TO RADIATION - DEMONSTRATION BY DUAL ENERGY QUANTITATIVE CT AND MR IMAGING
    ROSENTHAL, DI
    HAYES, CW
    ROSEN, B
    MAYOSMITH, W
    GOODSITT, MM
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (03) : 463 - 465
  • [25] Comparison of Voxel S-values and Monte Carlo Simulation in [177Lu]Lu-DOTA-TATE Quantification for Patient-Specific Dosimetry
    Rodrigues, C.
    Ferreira, P.
    Oliveira, F. P. M.
    Silva, A.
    Peralta, L.
    Costa, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S75 - S75
  • [26] Vertebral Compression Fractures: Third-Generation Dual-Energy CT for Detection of Bone Marrow Edema at Visual and Quantitative Analyses
    Petritsch, Bernhard
    Kosmala, Aleksander
    Weng, Andreas M.
    Krauss, Bernhard
    Heidemeier, Anke
    Wagner, Richard
    Heintel, Timo M.
    Gassenmaier, Tobias
    Bley, Thorsten A.
    RADIOLOGY, 2017, 284 (01) : 161 - 168
  • [27] Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI
    Guillaume Bierry
    Aïna Venkatasamy
    Stéphane Kremer
    Jean-Claude Dosch
    Jean-Louis Dietemann
    Skeletal Radiology, 2014, 43 : 485 - 492
  • [28] Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI
    Bierry, Guillaume
    Venkatasamy, Aina
    Kremer, Stephane
    Dosch, Jean-Claude
    Dietemann, Jean-Louis
    SKELETAL RADIOLOGY, 2014, 43 (04) : 485 - 492
  • [29] Fat Fraction Measurements Using a Three-Material Decomposition Dual-Energy CT Technique Accounting for Bone Minerals: Evaluation in a Bone Marrow Phantom Using MRI as Reference
    Li, Baojun
    Hua, Ning
    Li, Janelle
    Andreu-Arasa, V. Carlota
    LeBedis, Christina
    Anderson, Stephan W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (03) : 553 - 554
  • [30] Inaccuracies inherent in dual-energy X-ray absorptiometry in vivo bone mineral density can seriously mislead diagnostic/prognostic interpretations of patient-specific bone fragility
    Bolotin, HH
    Sievänen, H
    JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (05) : 799 - 805