Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur Fractures

被引:68
|
作者
Otto, Randall J. [1 ]
Moed, Berton R. [1 ]
Bledsoe, J. Gary [2 ]
机构
[1] St Louis Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO 63110 USA
[2] St Louis Univ, Pk Coll Engn Aviat & Technol, Dept Biomed Engn, St Louis, MO 63110 USA
关键词
polyaxial; distal femur; locking plate; fracture fixation; biomechanics; INVASIVE STABILIZATION SYSTEM; BLADE PLATE; SCREW;
D O I
10.1097/BOT.0b013e3181a567c8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To test the stability to axial loading of 2 new polyaxial locking screw-plate designs and analyze different angles of screw insertion. The noncontact bridging (NCB) polyaxial locking plate (Zimmer) and the POLYAX plate (DePuy) were compared with a fixed-angle less invasive stabilization system (LISS; Synthes). Methods: Twenty-five synthetic femurs were divided into 5 groups and assigned fixation with the LISS plate (group I), POLYAX plate (groups IIA and IIB), or NCB plate (groups IIIA and IIIB). The polyaxial constructs were divided into parallel and crossed distal condylar screw configurations. Each construct was tested under axial loading and stressed to failure at a displacement rate of 5 mm/min with a preload of 100 N. Outcome measurements included stiffness, load to failure, peak force, and mode of failure, Results: All LISS and POLYAX constructs failed by plastic deformation of the plate, whereas 9 of 10 NCB constructs failed by an intraarticular lateral condyle fracture. No failures occurred at the screwplate interface in either polyaxial constructs. Load to failure of the LISS was 33% greater than the parallel POLYAX (P < 0.01) and 24% greater than the crossed POLYAX (P < 0.01). Load to failure of NCB (parallel and crossed) were 24% greater than the parallel POLYAX (P < 0.01 and P < 0.01, respectively) and 1501,, greater than the crossed POLYAX (P < 0.01 and P = 0.02, respectively). The POLYAX also had significantly lower stiffness and peak force compared with the LISS and NCB. There was no difference between the LISS and NCB with regard to stiffness, load to failure, and peak force. Parallel and crossed polyaxial constructs showed no difference in stiffness or failure loads. Conclusions: There were no failures of either polyaxial screw-plate interface despite large forces and screw angle did not affect the overall strength of these constructs, supporting the biomechanical soundness of both polyaxial device designs under axial loading. However, the POLYAX supported smaller loads compared with the LISS and NCB while under axial loading. In addition, the mode of failure of the NCB plate, creating an intra-articular fracture propagating from the distal posterior screw hole, may be of some concern. Additional testing is needed to determine the clinical importance of the demonstrated differences among these plate designs.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 50 条
  • [31] Biomechanical analysis of distal femur fracture fixation: Fixed-angle screw-plate construct versus condylar blade plate
    Higgins, Thomas F.
    Pittman, Gavin
    Hines, Jerod
    Bachus, Kent N.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (01) : 43 - 46
  • [32] Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: A biomechanical study
    Minihane, Keith P.
    Lee, Chris
    Ahn, Chulhyun
    Zhang, Li-Qun
    Merk, Bradley R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (08) : 562 - 566
  • [33] Polyaxial versus uniaxial volar locking plate for distal radial fractures
    Al-Mouazzen, Louay
    Chou, Daud Tai Shan
    Kyriakopoulos, Georgios
    Hambidge, John
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01) : 9 - 12
  • [34] A Biomechanical Comparison of Locking Versus Conventional Plate Fixation for Distal Fibula Fractures in Trimalleolar Ankle Injuries
    Nguyentat, Annie
    Camisa, William
    Patel, Sandeep
    Lagaay, Pieter
    JOURNAL OF FOOT & ANKLE SURGERY, 2016, 55 (01): : 132 - 135
  • [35] Comparison of different locking plate fixation methods in distal tibia fractures
    Piatkowski, Krzysztof
    Piekarczyk, Piotr
    Kwiatkowski, Krzysztof
    Przybycien, Mateusz
    Chwedczuk, Bartlomiej
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2245 - 2251
  • [36] Comparison of different locking plate fixation methods in distal tibia fractures
    Krzysztof Piątkowski
    Piotr Piekarczyk
    Krzysztof Kwiatkowski
    Mateusz Przybycień
    Bartłomiej Chwedczuk
    International Orthopaedics, 2015, 39 : 2245 - 2251
  • [37] STUDY OF FUNCTIONAL OUTCOME OF DISTAL FEMUR FRACTURES TREATED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE
    Jose, R. Sahaya
    Krishnan, N. Gopala
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (35): : 1984 - 1991
  • [38] Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial
    Hanschen, Marc
    Aschenbrenner, Ina M.
    Fehske, Kai
    Kirchhoff, Sonja
    Keil, Leonhard
    Holzapfel, Boris M.
    Winkler, Sebastian
    Fuechtmeier, Bernd
    Neugebauer, Rainer
    Luehrs, Sven
    Liener, Ulrich
    Biberthaler, Peter
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 857 - 863
  • [39] Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial
    Marc Hanschen
    Ina M. Aschenbrenner
    Kai Fehske
    Sonja Kirchhoff
    Leonhard Keil
    Boris M. Holzapfel
    Sebastian Winkler
    Bernd Fuechtmeier
    Rainer Neugebauer
    Sven Luehrs
    Ulrich Liener
    Peter Biberthaler
    International Orthopaedics, 2014, 38 : 857 - 863
  • [40] Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference?
    Abdel-Wahed, Mohamed
    Khater, Ahmed Abdel-Zaher
    El-Desouky, Mahmoud Ahmed
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (09) : 2165 - 2176