Computation of full energy peak efficiency for nuclear power plant radioactive plume using remote scintillation gamma-ray spectrometry

被引:1
|
作者
Grozdov, D. S. [1 ]
Kolotov, V. P. [1 ]
Lavrukhin, Yu. E. [1 ]
机构
[1] Russian Acad Sci, Inst Geochem & Analyt Chem, Kosigyna 19, Moscow 119991, Russia
关键词
Full energy peak efficiency; Gamma-ray spectrometry; Collimated detector; NPP plume; NaI(Tl); HPGE DETECTOR; CALIBRATION; CODE;
D O I
10.1016/j.apradiso.2016.01.014
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A method of full energy peak efficiency estimation in the space around scintillation detector, including the presence of a collimator, has been developed. It is based on a mathematical convolution of the experimental results With the following data extrapolation. The efficiency data showed the average uncertainty less than 10%. Software to calculate integral efficiency for nuclear power plant plume was elaborated. The paper also provides results of nuclear power plant plume height estimation by analysis of the spectral data. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [21] Acquiring Gamma-Ray Energy Spectrum Using a Plastic Scintillation Optical Fiber Detector
    Song, Siwon
    Park, Jae Hyung
    Kim, Jinhong
    Kim, Seunghyeon
    Jegal, Seokhyeon
    Lee, Sangjun
    Lee, Bongsoo
    PHOTONICS, 2024, 11 (06)
  • [22] Development of PC-based nuclear instruments for gamma-ray spectroscopy using scintillation detectors
    Ghaousia, SF
    Mirza, NM
    Mirza, SM
    COMPUTERS IN PHYSICS, 1997, 11 (05): : 516 - 519
  • [23] GAMMA-RAY IRRADIATION TEST OF AN OPTICAL REMOTE MULTIPLEXING SYSTEM FOR A NUCLEAR-POWER STATION
    YAMAUCHI, T
    ADACHI, K
    HANAI, K
    OHHASHI, H
    HAJIMA, S
    NOGUCHI, A
    ISHII, K
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1983, 45 : 675 - 676
  • [24] Full energy peak efficiency calibration for the assay of large volume radioactive waste drums in a segmented gamma scanner
    Patra, Sabyasachi
    Agarwal, Chhavi
    Chaudhury, Sanhita
    APPLIED RADIATION AND ISOTOPES, 2019, 144 : 80 - 86
  • [25] Correlation between peak energy and Fourier power density spectrum slope in gamma-ray bursts
    Dichiara, S.
    Guidorzi, C.
    Amati, L.
    Frontera, F.
    Margutti, R.
    ASTRONOMY & ASTROPHYSICS, 2016, 589
  • [26] EFFLUENT MONITORING IN NUCLEAR-PLANTS USING ON-LINE GAMMA-RAY SPECTROMETRY
    HEATH, RL
    CLINE, JE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (01) : 65 - 72
  • [27] LOCAL NUCLEAR-REACTOR POWER MEASUREMENTS USING GAMMA-RAY FLUCTUATIONS
    LEVERT, FE
    SCHULTZ, MA
    NUCLEAR SCIENCE AND ENGINEERING, 1972, 49 (02) : 188 - &
  • [28] HIGH-ENERGY GAMMA-RAY DOSIMETRY - EXPERIMENTAL MEASUREMENTS AT A NUCLEAR POWER STATION
    HOLT, PD
    GIBSON, JAB
    JOURNAL OF NUCLEAR ENERGY PARTS A AND B-REACTOR SCIENCE AND TECHNOLOGY, 1965, 19 (1PA-): : 17 - &
  • [29] Total versus effective total efficiency in the computation of coincidence summing corrections in gamma-ray spectrometry of volume sources
    D. Arnold
    O. Sima
    Journal of Radioanalytical and Nuclear Chemistry, 2001, 248 : 365 - 370
  • [30] Total versus effective total efficiency in the computation of coincidence summing corrections in gamma-ray spectrometry of volume sources
    Arnold, D
    Sima, O
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 248 (02) : 365 - 370