摘要
Background and purpose: We are developing a technique for highly focused vocal cord irradiation in early glottic carcinoma to optimally treat a target volume confined to a single cord. This technique, in contrast with the conventional methods, aims at sparing the healthy vocal cord. As such a technique requires sub-mm daily targeting accuracy to be effective, we investigate the accuracy achievable with on-line kV-cone beam CT (CBCT) corrections. Materials and methods: CBCT scans were obtained in 10 early glottic cancer patients in each treatment fraction. The grey value registration available in X-ray volume imaging (XVI) software (Elekta, Synergy) was applied to a volume of interest encompassing the thyroid cartilage. After application of the thus derived corrections, residue displacements with respect to the planning CT scan were measured at clearly identifiable relevant landmarks. The intra- and inter-observer variations were also measured. Results: While before correction the systematic displacements of the vocal cords were as large as 2.4 +/- 3.3 mm (cranial-caudal population mean +/- SD Sigma), daily CBCT registration and correction reduced these values to less than 0.2 +/- 0.5 mm in all directions. Random positioning errors (SD sigma) were reduced to less than 1 mm. Correcting only for translations and not for rotations did not appreciably affect this accuracy. The residue random displacements partly stem from intra-observer variations (SD = 0.2-0.6 mm). Conclusion: The use of CBCT for daily image guidance in combination with standard mask fixation reduced systematic and random set-up errors of the vocal cords to <1 mm prior to the delivery of each fraction dose. Thus, this facilitates the high targeting precision required for a single vocal cord irradiation. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 93 (2009) 8-13
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [1] DAILY CONE-BEAM CT IMAGE GUIDANCE FOR SINGLE VOCAL CORD TARGETING
    Osman, S.
    de Boer, H.
    Gangsaas, A.
    Heijmen, B.
    Levendag, P.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S369 - S370
  • [2] On-line tumor perfusion measurement with contrast enhanced cone beam CT
    Yeung, I
    Cho, YB
    Kim, S
    Zhao, S
    Haider, M
    Milosevic, M
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S77 - S78
  • [3] Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: Localization, verification, and intrafraction tumor position
    Purdie, Thomas G.
    Bissonnette, Jean-Pierre
    Franks, Kevin
    Bezjak, Andrea
    Payne, David
    Sie, Fanny
    Sharpe, Michael B.
    Jaffray, David A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01): : 243 - 252
  • [4] On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT)
    Bak, Jino
    Jeong, Kyoungkeun
    Keum, Ki Chang
    Park, Suk Won
    RADIATION ONCOLOGY JOURNAL, 2006, 24 (04): : 294 - 299
  • [5] TUMOR BASELINE SHIFT FOR NSCLC SBRT TREATMENT WITH CONE-BEAM CT IMAGE GUIDANCE
    Bouilhol, G.
    Ayadi, M.
    Hau, N. H.
    Gassa, F.
    Sarrut, D.
    Ginestet, C.
    Claude, L.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S167 - S167
  • [6] Cone-beam CT: Applications in image-guidance
    Jaffray, DA
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S12 - S12
  • [7] Constrained Arithmetic Reconstruction for On-Line Tumor Perfusion Imaging with Contrast Enhanced Cone Beam CT
    Cho, Y.
    Yeung, I.
    Kim, S.
    Haider, A.
    Milosevic, M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2251 - 2254
  • [8] ON-LINE DOSE CALCULATION ON CONE BEAM CT FOR LUNG TUMORS
    van Rooijen, D.
    Van Wieringen, N.
    Bel, A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S132 - S132
  • [9] Probabilistic analysis of cord position in daily on-line cone beam CT imaging for head and neck radiotherapy
    Breen, S. L.
    Thomas, C.
    Vakilhal, M.
    Bayley, A.
    Dawson, L.
    Cuinming, B.
    Kim, J.
    Ringash, J.
    O'Sullivan, B.
    Waldron, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S656 - S657
  • [10] On-line image guidance for frameless stereotactic radiotherapy of lung malignancies by cone beam CT: Comparison between target localization and alignment on bony anatomy
    Masi, Laura
    Casamassima, Franco
    Menichelli, Claudia
    Pasciuti, Katia
    Doro, Raffaela
    Polli, Caterina
    D'Imporzano, Elena
    Bonucci, Ivano
    ACTA ONCOLOGICA, 2008, 47 (07) : 1422 - 1431