Parallel particle impactor - novel size-selective particle sampler for accurate fractioning of inhalable particles

被引:8
|
作者
Trakumas, S.
Salter, E.
机构
[1] SKC Inc., Eighty Four, PA 15330
[2] SKC Ltd., Blandford Forum, Dorset, DT11 8ST, 11 Sunrise Park, Higher Shaftesbury Road
来源
INHALED PARTICLES X | 2009年 / 151卷
关键词
AEROSOL SAMPLERS; VIRTUAL CYCLONE; CALM AIR; PENETRATION; COLLECTION; EFFICIENCY;
D O I
10.1088/1742-6596/151/1/012060
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Adverse health effects due to exposure to airborne particles are associated with particle deposition within the human respiratory tract. Particle size, shape, chemical composition, and the individual physiological characteristics of each person determine to what depth inhaled particles may penetrate and deposit within the respiratory tract. Various particle inertial classification devices are available to fractionate airborne particles according to their aerodynamic size to approximate particle penetration through the human respiratory tract. Cyclones are most often used to sample thoracic or respirable fractions of inhaled particles. Extensive studies of different cyclonic samplers have shown, however, that the sampling characteristics of cyclones do not follow the entire selected convention accurately. In the search for a more accurate way to assess worker exposure to different fractions of inhaled dust, a novel sampler comprising several inertial impactors arranged in parallel was designed and tested. The new design includes a number of separated impactors arranged in parallel. Prototypes of respirable and thoracic samplers each comprising four impactors arranged in parallel were manufactured and tested. Results indicated that the prototype samplers followed closely the penetration characteristics for which they were designed. The new samplers were found to perform similarly for liquid and solid test particles; penetration characteristics remained unchanged even after prolonged exposure to coal mine dust at high concentration. The new parallel impactor design can be applied to approximate any monotonically decreasing penetration curve at a selected flow rate. Personal-size samplers that operate at a few L/min as well as area samplers that operate at higher flow rates can be made based on the suggested design. Performance of such samplers can be predicted with high accuracy employing well-established impaction theory.
引用
收藏
页数:16
相关论文
共 49 条
  • [41] Fabrication and characterization of myofibrillar microgel particles as novel Pickering stabilizers: Effect of particle size and wettability on emulsifying capacity
    Sun, Yi
    Ma, Liang
    Fu, Yu
    Dai, Hongjie
    Zhang, Yuhao
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2021, 151
  • [42] Size-selective purification of hepatitis B virus-like particle in flow-through chromatography: Types of ion exchange adsorbent and grafted polymer architecture
    Ng, Hon Wei
    Lee, Micky Fu Xiang
    Chua, Gek Kee
    Gan, Bee Koon
    Tan, Wen Siang
    Ooi, Chien Wei
    Tang, Siah Ying
    Chan, Eng Seng
    Tey, Beng Ti
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (10) : 2119 - 2129
  • [43] Selective Removal of Particles and Shifting of Particle-Size Distribution during Pipeline Transport of Sediment Deposits under Turbulent Flow
    Zeinali, Hossein
    Toma, Peter
    Kuru, Ergun
    JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2016, 7 (04)
  • [44] Organic solvent-resistant and thermally stable polymeric microfiltration membranes based on crosslinked polybenzoxazine for size-selective particle separation and gravity-driven separation on oil-water emulsions
    Zhong, Ming
    Su, Po-Kai
    Lai, Juin-Yih
    Liu, Ying-Ling
    JOURNAL OF MEMBRANE SCIENCE, 2018, 550 : 18 - 25
  • [45] A novel approach for adapting the standard addition method to single particle-ICP-MS for the accurate determination of NP size and number concentration in complex matrices
    Aramendia, Maite
    Carlos Garcia-Mesa, Juan
    Vereda Alonso, Elisa
    Garde, Raul
    Bazo, Antonio
    Resano, Javier
    Resano, Martin
    ANALYTICA CHIMICA ACTA, 2022, 1205
  • [46] A novel approach for adapting the standard addition method to single particle-ICP-MS for the accurate determination of NP size and number concentration in complex matrices
    Aramendía, Maite
    García-Mesa, Juan Carlos
    Alonso, Elisa Vereda
    Garde, Raúl
    Bazo, Antonio
    Resano, Javier
    Resano, Martín
    Analytica Chimica Acta, 2022, 1205
  • [47] Regulation of sulfur doping on carbon-supported Pd particles and abnormal relationship between Pd particle size and catalytic performance in selective hydrogenation of o-chloronitrobenzene
    Zhang, Qunfeng
    Zhou, Yuan
    Xu, Yiqi
    Wang, Qingtao
    Huang, Weimin
    Ying, Juntao
    Zhou, Jing
    Ma, Lei
    Lu, Chunshan
    Feng, Feng
    Li, Xiaonian
    CATALYSIS COMMUNICATIONS, 2020, 143
  • [48] Centrifugal tester versus a novel design to measure particle adhesion strength and investigation of effect of physical characteristics (size, shape, density) of food particles on food surfaces
    Ermis, E.
    Farnish, R. J.
    Berry, R. J.
    Bradley, M. S. A.
    JOURNAL OF FOOD ENGINEERING, 2011, 104 (04) : 518 - 524
  • [49] Exposure assessment of nanotitanium oxide powder handling using real-time size-selective particle number concentration measurements and X-ray fluorescence spectrometry - The possibility of exposure to nonagglomerated nanomaterials during the handling of nanomaterial fine powders
    Takaya, Mitsutoshi
    Yamada, Maromu
    Kobayashi, Kenichi
    Higashikubo, Ichiro
    Hagiwara, Masayoshi
    Ono-Ogasawara, Mariko
    INDUSTRIAL HEALTH, 2022, 60 (03) : 253 - 265