Average 3-Dimensional Models for the Comparison of Orbscan II and Pentacam Pachymetry Maps in Normal Corneas

被引:60
|
作者
Bourges, Jean-Louis [2 ]
Alfonsi, Nicolas [2 ]
Laliberte, Jean-Francois
Chagnon, Miguel [3 ]
Renard, Gilles [2 ]
Legeais, Jean-Marc [2 ]
Brunette, Isabelle [1 ,4 ]
机构
[1] Hop Maison Neuve Rosemont, Dept Ophthalmol, Res Ctr, Montreal, PQ H1T 2M4, Canada
[2] Paris Descartes Univ, Dept Ophthalmol, Hop Hotel Dieu, AP HP, Paris, France
[3] Univ Montreal, Dept Math & Stat, Montreal, PQ H3C 3J7, Canada
[4] Univ Montreal, Dept Ophthalmol, Montreal, PQ, Canada
关键词
NONCONTACT SPECULAR MICROSCOPY; THICKNESS MEASUREMENTS; ULTRASOUND PACHYMETRY; REFRACTIVE SURGERY; SCHEIMPFLUG CAMERA; REPEATABILITY; TOPOGRAPHY; PACHOMETRY; AGREEMENT; VARIABILITY;
D O I
10.1016/j.ophtha.2009.04.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the reliability of Orbscan (Bausch & Lomb, Salt Lake City, UT) and Pentacam (Oculus, Wetzlar, Germany) central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements based on 2 methodologies. Design: Evaluation of a diagnostic technology. Participants: Thirty healthy volunteers were recruited prospectively at the Department of Ophthalmology of the Hotel-Dieu Hospital, Paris, France. Methods: Central corneal thickness and PCT were assessed, using ultrasound pachymetry (USP) as the gold standard. Two methodologies were used: (1) the traditional analysis of pachymetry data from 1 central and 8 peripheral reference positions on the cornea, and (2) a 3-dimensional (3-D) analysis based on average corneal pachymetry maps constructed for each system (Orbscan, Pentacam, and USP), each operator (operators 1 and 2), and each visit (visits A and B). Main Outcome Measures: Repeatability, intersystem reproducibility, interoperator reproducibility, reproducibility over time, and accuracy of Orbscan and Pentacam CCT and PCT measurements. Distribution and statistical significance of the differences between 3-D average maps. Results: Repeatability (Orbscan intraclass correlation coefficients [ICCs], 0.967-0.992; Pentacam ICCs, 0.986-0.997), interoperator reproducibility, and reproducibility over time (ICCs, 0.976-0.997) were excellent to almost perfect for both systems. Intersystem agreement was almost perfect for CCT (ICC, 0.980), but less strong for PCT (ICCs, 0.928-0.979). Despite a good to excellent agreement between the optical systems and USP (ICCs, 0.608-0.958), LISP CCT readings were thicker (mean difference, up to 15.2 mu m; P<0.05), and LISP PCT readings were thinner (P<0.05). Orbscan and Pentacam average maps allowed comprehensive interpretation of differences between populations according to the magnitude, distribution, and statistical significance, minimizing the risk of giving excessive weight to few data measured at specific locations on the cornea. Conclusions: Both methodologies showed that Orbscan and Pentacam CCT readings are interchangeable, whereas caution should be used for PCT readings. Interchangeability with USP measurements also was shown to be limited. The high repeatability, interoperator reproducibility, reproducibility over time, the extent of the information generated by a single capture, and the noncontact nature of the Orbscan and Pentacam all suggest that optical systems eventually may replace LISP as the gold standard for corneal pachymetry. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2009; 116:2064-2071 (C) 2009 by the American Academy of Ophthalmology.
引用
收藏
页码:2064 / 2071
页数:8
相关论文
共 50 条
  • [41] Evaluation of Growth and Development of Late Mixed Dentition Upper Dental Arch with Normal Occlusion Using 3-Dimensional Digital Models
    Yang, Dapeng
    Liang, Shuran
    Zhang, Ke
    Gao, Weimin
    Bai, Yuxing
    JOURNAL OF HEALTHCARE ENGINEERING, 2019, 2019
  • [42] Donor-recipient matching in hand transplantation: a comparison of anthropometric measurements, 3-dimensional virtual models and printed epitheses
    Ruiz-Moya, Alejandro
    Infante-Cossio, Pedro
    Gomez-Ciriza, Gorka
    Gomez-Ciriza, Mikel
    Gomez-Cia, Tomas
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2021, 46 (09) : 995 - 1002
  • [43] Comparison of 3-Dimensional and Augmented Reality Kidney Models With Conventional Imaging Data in the Preoperative Assessment of Children With Wilms Tumors
    Wellens, Lianne M.
    Meulstee, Jene
    van de Ven, Cornelis P.
    van Scheltinga, C. E. J. Terwisscha
    Littooij, Annemieke S.
    van den Heuvel-Eibrink, Marry M.
    Fiocco, Marta
    Rios, Anne C.
    Maal, Thomas
    Wijnen, Marc H. W. A.
    JAMA NETWORK OPEN, 2019, 2 (04)
  • [44] A COMPARISON OF 3-DIMENSIONAL GROWTH-CHARACTERISTICS OF CULTURED PRIMITIVE MARROW STROMA DERIVED FROM GENETICALLY ANEMIC AND NORMAL MICE
    DANIELS, E
    JOURNAL OF THE RETICULOENDOTHELIAL SOCIETY, 1983, 33 (06): : 457 - 465
  • [45] PI- DELTA- AND GAMMA-CHYMOTRYPSIN - 3-DIMENSIONAL ELECTRON-DENSITY AND DIFFERENCE MAPS AT 5 A RESOLUTION AND COMPARISON WITH CHYMOTRYPSINOGEN
    KRAUT, J
    WRIGHT, HT
    KELLERMAN, M
    FREER, ST
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1967, 58 (01) : 304 - +
  • [46] Laser scanner and drone photogrammetry: A statistical comparison between 3-dimensional models and its impacts on outdoor crime scene registration
    Cunha, Rafael Rodrigues
    Arrabal, Claude Thiago
    Dantas, Marcelo Mourao
    Bassaneli, Helio Rodrigues
    FORENSIC SCIENCE INTERNATIONAL, 2022, 330
  • [47] Normal values of right ventricular size and function by real-time 3-dimensional echocardiography: Comparison with cardiac magnetic resonance imaging
    Gopal, Aasha S.
    Chukwu, Ebere O.
    Iwuchukwu, Chizor J.
    Katz, Alan S.
    Toole, Rena S.
    Schapiro, William
    Reichek, Nathaniel
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (05) : 445 - 455
  • [48] Comparison of follicular vascularization in normal versus polycystic ovaries during in vitro fertilization as measured using 3-dimensional power Doppler ultrasonography
    Järvelä, IY
    Sladkevicius, P
    Kelly, S
    Ojha, K
    Campbell, S
    Nargund, G
    FERTILITY AND STERILITY, 2004, 82 (05) : 1358 - 1363
  • [50] QUANTIFICATION OF THE LEFT-VENTRICULAR VOLUMES AND FUNCTION WITH CINE MR-IMAGING - COMPARISON OF GEOMETRIC-MODELS WITH 3-DIMENSIONAL DATA
    DULCE, MC
    MOSTBECK, GH
    FRIESE, KK
    CAPUTO, GR
    HIGGINS, CB
    RADIOLOGY, 1993, 188 (02) : 371 - 376