Average 3-Dimensional Models for the Comparison of Orbscan II and Pentacam Pachymetry Maps in Normal Corneas

被引:60
|
作者
Bourges, Jean-Louis [2 ]
Alfonsi, Nicolas [2 ]
Laliberte, Jean-Francois
Chagnon, Miguel [3 ]
Renard, Gilles [2 ]
Legeais, Jean-Marc [2 ]
Brunette, Isabelle [1 ,4 ]
机构
[1] Hop Maison Neuve Rosemont, Dept Ophthalmol, Res Ctr, Montreal, PQ H1T 2M4, Canada
[2] Paris Descartes Univ, Dept Ophthalmol, Hop Hotel Dieu, AP HP, Paris, France
[3] Univ Montreal, Dept Math & Stat, Montreal, PQ H3C 3J7, Canada
[4] Univ Montreal, Dept Ophthalmol, Montreal, PQ, Canada
关键词
NONCONTACT SPECULAR MICROSCOPY; THICKNESS MEASUREMENTS; ULTRASOUND PACHYMETRY; REFRACTIVE SURGERY; SCHEIMPFLUG CAMERA; REPEATABILITY; TOPOGRAPHY; PACHOMETRY; AGREEMENT; VARIABILITY;
D O I
10.1016/j.ophtha.2009.04.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the reliability of Orbscan (Bausch & Lomb, Salt Lake City, UT) and Pentacam (Oculus, Wetzlar, Germany) central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements based on 2 methodologies. Design: Evaluation of a diagnostic technology. Participants: Thirty healthy volunteers were recruited prospectively at the Department of Ophthalmology of the Hotel-Dieu Hospital, Paris, France. Methods: Central corneal thickness and PCT were assessed, using ultrasound pachymetry (USP) as the gold standard. Two methodologies were used: (1) the traditional analysis of pachymetry data from 1 central and 8 peripheral reference positions on the cornea, and (2) a 3-dimensional (3-D) analysis based on average corneal pachymetry maps constructed for each system (Orbscan, Pentacam, and USP), each operator (operators 1 and 2), and each visit (visits A and B). Main Outcome Measures: Repeatability, intersystem reproducibility, interoperator reproducibility, reproducibility over time, and accuracy of Orbscan and Pentacam CCT and PCT measurements. Distribution and statistical significance of the differences between 3-D average maps. Results: Repeatability (Orbscan intraclass correlation coefficients [ICCs], 0.967-0.992; Pentacam ICCs, 0.986-0.997), interoperator reproducibility, and reproducibility over time (ICCs, 0.976-0.997) were excellent to almost perfect for both systems. Intersystem agreement was almost perfect for CCT (ICC, 0.980), but less strong for PCT (ICCs, 0.928-0.979). Despite a good to excellent agreement between the optical systems and USP (ICCs, 0.608-0.958), LISP CCT readings were thicker (mean difference, up to 15.2 mu m; P<0.05), and LISP PCT readings were thinner (P<0.05). Orbscan and Pentacam average maps allowed comprehensive interpretation of differences between populations according to the magnitude, distribution, and statistical significance, minimizing the risk of giving excessive weight to few data measured at specific locations on the cornea. Conclusions: Both methodologies showed that Orbscan and Pentacam CCT readings are interchangeable, whereas caution should be used for PCT readings. Interchangeability with USP measurements also was shown to be limited. The high repeatability, interoperator reproducibility, reproducibility over time, the extent of the information generated by a single capture, and the noncontact nature of the Orbscan and Pentacam all suggest that optical systems eventually may replace LISP as the gold standard for corneal pachymetry. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2009; 116:2064-2071 (C) 2009 by the American Academy of Ophthalmology.
引用
收藏
页码:2064 / 2071
页数:8
相关论文
共 50 条
  • [1] Measurement of central corneal thickness using Orbscan 3, Pentacam HR and ultrasound pachymetry in normal eyes
    Hesham Mohamed Gharieb
    Doaa Maamoun Ashour
    Mohamed Ibrahim Saleh
    Ihab Saad Othman
    International Ophthalmology, 2020, 40 : 1759 - 1764
  • [2] Measurement of central corneal thickness using Orbscan 3, Pentacam HR and ultrasound pachymetry in normal eyes
    Gharieb, Hesham Mohamed
    Ashour, Doaa Maamoun
    Saleh, Mohamed Ibrahim
    Othman, Ihab Saad
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (07) : 1759 - 1764
  • [3] A geometric quadratic form of 3-dimensional normal maps
    Morimoto, M
    TOPOLOGY AND ITS APPLICATIONS, 1998, 83 (02) : 77 - 102
  • [4] A COMPARISON OF 3-DIMENSIONAL SEISMIC MODELS
    GRAY, LJ
    GEOPHYSICS, 1986, 51 (06) : 1328 - 1328
  • [5] Average Models and 3-dimensional Growth Patterns of the Healthy Infant Cranium
    Kuwahara, Kosuke
    Hikosaka, Makoto
    Takamatsu, Ako
    Miyazaki, Osamu
    Nosaka, Shunsuke
    Ogawa, Rei
    Kaneko, Tsuyoshi
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2020, 8 (08)
  • [6] A COMPARISON BETWEEN 3-DIMENSIONAL MODELS OF MUREIN AND PSEUDOMUREIN
    LABISCHINSKI, H
    BARNICKEL, G
    LEPS, B
    BRADACZEK, H
    GIESBRECHT, P
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1980, 22 (01) : 464 - 464
  • [7] A TEMPLATE FOR GENERATION AND COMPARISON OF 3-DIMENSIONAL SELECTIN MODELS
    BAJORATH, J
    ARUFFO, A
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1995, 216 (03) : 1018 - 1023
  • [8] COMPARISON OF 3-DIMENSIONAL NUMERICAL DIFFRACTION-RADIATION MODELS
    SUSBIELLES, G
    BERHAULT, C
    REVUE DE L INSTITUT FRANCAIS DU PETROLE, 1978, 33 (04): : 537 - 553
  • [9] COMPARISON BETWEEN 3-DIMENSIONAL AND TWO-DIMENSIONAL MODELS OF ELASTICITY PLATES
    DESTUYNDER, P
    RAIRO-ANALYSE NUMERIQUE-NUMERICAL ANALYSIS, 1981, 15 (04): : 331 - 369