Recovery of mortar-aggregate interface of fire-damaged concrete after post-fire curing

被引:6
|
作者
Li, Lang [1 ,2 ]
Zhang, Hong [2 ]
Dong, Jiangfeng [1 ]
Zhang, Hongen [1 ]
Jia, Pu [3 ]
Wang, Qingyuan [1 ]
Liu, Yongjie [2 ]
机构
[1] Sichuan Univ, Coll Architecture & Environm, Failure Mech & Engn Disaster Prevent & Mitigat Ke, Chengdu 610065, Sichuan, Peoples R China
[2] Sichuan Univ, Key Lab Deep Underground Sci & Engn, Minist Educ, Chengdu 610065, Sichuan, Peoples R China
[3] Sichuan Univ, Inst Disaster Management & Reconstruct, Chengdu 610065, Sichuan, Peoples R China
来源
COMPUTERS AND CONCRETE | 2019年 / 24卷 / 03期
基金
中国国家自然科学基金;
关键词
concrete; high temperature; post-fire curing; mortar-aggregate interface; image analysis; CEMENT-BASED COMPOSITE; THERMAL INDUCED STRESS; MECHANICAL-PROPERTIES; COMPRESSIVE STRENGTH; HIGH-TEMPERATURES; ELEVATED-TEMPERATURES; BEHAVIOR; CRACKING; PASTE; DEHYDRATION;
D O I
10.12989/cac.2019.24.3.249
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In order to investigate the strength recovery of fire-damaged concrete after post-fire curing, concrete specimens were heating at 2 degrees C/min or 5 degrees C/min to 400, 600 and 800 degrees C, and these exposed specimens were soaked in the water for 24 hours and following by 29-day post-fire curing. The compressive strength and split tensile strength of the high-temperature-exposed specimens before and after post-fire curing were tested. The proportion of split aggregate in the split surfaces was analyzed to evaluate the mortar-aggregate interfacial strength. After the post-fire curing process, the split tensile strength of specimens exposed to all temperatures was recovered significantly, while the recovery of compressive strength was only obvious within the specimens exposed to 600 degrees C. The tensile strength is more sensitive to the mortar-aggregate interfacial cracks, which caused that the split tensile strength decreased more after high-temperature exposure and recovery more after post-fire curing than the compressive strength. The mortar-aggregate interfacial strength also showed remarkable recovery after post-fire curing, and it contributed to the recovery of split tensile strength.
引用
收藏
页码:249 / 258
页数:10
相关论文
共 50 条
  • [21] The Colorimetry Method in Assessing Fire-Damaged Concrete
    Wei, Ya
    Kong, Wei-Kang
    Wan, Cheng
    Wang, Ya-Qiong
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2019, 17 (06) : 282 - 294
  • [22] FIRE-DAMAGED CONCRETE STRUCTURES - REBUILD OR REPAIR
    JAMES, ML
    TIMSON, DJ
    CONCRETE, 1972, 6 (06): : 22 - &
  • [23] GUNITE REPAIRS TO FIRE-DAMAGED CONCRETE STRUCTURES
    GREEN, JK
    LONG, WB
    CONCRETE, 1971, 5 (04): : 118 - &
  • [24] Colorimetry method in assessing fire-damaged concrete
    Wei Y.
    Kong W.-K.
    Wan C.
    Zuo Y.-Z.
    Lu Q.-Z.
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2021, 51 (01): : 233 - 244
  • [25] Assessing concrete strength in fire-damaged structures
    Wroblewska, Julia
    Kowalski, Robert
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 254
  • [26] Repairing a fire-damaged concrete turbine pedestal
    Dorsch, David
    Concrete International, 1991, 13 (06) : 33 - 38
  • [27] Evaluation of mechanical properties and post-fire cured strength recovery of recycled aggregate concrete
    Suresh, N.
    Rao, Vadiraj
    Akshay, B. S.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2022, 13 (04) : 491 - 505
  • [28] Repair of fire-damaged reinforced concrete columns
    Lin, Chien-Hung
    Chen, Shun-Tyan
    Yang, Chen-An
    ACI Materials Journal, 1995, 92 (04) : 406 - 411
  • [29] Predicting post-fire behavior of crumb rubber aggregate concrete
    Mousavimehr, Mehdi
    Nematzadeh, Mahdi
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 229
  • [30] Improvement of post-fire properties of concrete with steel slag aggregate
    Netinger, Ivanka
    Rukavina, Marija Jelcic
    Mladenovic, Ana
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 745 - 753