Echo-planar MR imaging of dissolved hyperpolarized 129Xe -: Potential for MR angiography

被引:4
|
作者
Månsson, S [1 ]
Johansson, E
Svensson, J
Olsson, LE
Ståhlberg, F
Petersson, JS
Golman, K
机构
[1] Malmo Univ Hosp, Dept Expt Res, SE-20502 Malmo, Sweden
[2] Univ Lund Hosp, Dept Radiat Phys, Lund, Sweden
[3] Malmo Univ Hosp, Dept Radiat Phys, Malmo, Sweden
[4] Univ Lund Hosp, Dept Radiol, Lund, Sweden
[5] Amersham Hlth R&D, Malmo, Sweden
关键词
MR angiography; hyperpolarized gas; dissolved xenon-129; echo-planar imaging; experimental;
D O I
10.1034/j.1600-0455.2002.430503.x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The feasibility of hyperpolarized Xe-129 for fast MR angiography (MRA) was evaluated using the echo-planar imaging (EPI) technique. Material and Methods: Hyperpolarized Xe gas was dissolved in ethanol, a carrier agent with high solubility for Xe (Ostwald solubility coefficient 2.5) and long relaxation times. The dissolved Xe was injected as a bolus into a flow phantom where the mean flow velocity was 15 cm/s. Ultrafast EPI images with 44 ms scan time were acquired of the flowing bolus and the signal-to-noise ratios (SNR) were measured. Results: The relaxation times of hyperpolarized Xe in ethanol were measured to T1 = 160+/-11 s and T2approximate to20 s. The resulting images of the flowing liquid were of reasonable quality and had an SNR of about 70. Conclusion: Based on the SNR of the obtained Xe EPI images, it was estimated that rapid in vivo MRA with Xe-129 may be feasible, provided that an efficient, biologically acceptable carrier for Xe can be found and polarization levels of more than 25% can be achieved in isotopically enriched Xe-129.
引用
收藏
页码:455 / 460
页数:6
相关论文
共 50 条
  • [21] Feasibility of a low-field MR imager using hyperpolarized 129Xe
    McDonald, M
    Cross, A
    Santyr, G
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2857 - 2860
  • [22] Hyperpolarized Xe-129 MR imaging of the oral cavity
    Albert, MS
    Tseng, CH
    Williamson, D
    Oteiza, ER
    Walsworth, RL
    Kraft, B
    Kacher, D
    Holman, BL
    Jolesz, FA
    JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 111 (02): : 204 - 207
  • [23] Review of Hyperpolarized Pulmonary Functional 129Xe MR for Long-COVID
    Wild, Jim M.
    Gleeson, Fergus V.
    Svenningsen, Sarah
    Grist, James T.
    Saunders, Laura C.
    Collier, Guilhem J.
    Sharma, Maksym
    Tcherner, Sam
    Mozaffaripour, Ali
    Matheson, Alexander M.
    Parraga, Grace
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (04) : 1120 - 1134
  • [24] Assessment of Gas Exchange With Hyperpolarized 129Xe MR Imaging in Mild Asthmatics When Administered a Vasodilator
    Delgado, G. M. Garcia
    Shammi, U.
    Ruppel, M.
    Mummy, D.
    Lu, J.
    Altes, T. A.
    Mugler, J. P., III
    Driehuys, B.
    Thomen, R. P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [25] Pulmonary Perfusion and Xenon Gas Exchange in Rats: MR Imaging with Intravenous Injection of Hyperpolarized 129Xe
    Driehuys, Bastiaan
    Moeller, Harald E.
    Cleveland, Zackary I.
    Pollaro, James
    Hedlund, Laurence W.
    RADIOLOGY, 2009, 252 (02) : 386 - 393
  • [26] Pediatric Hyperpolarized 129xe Mr Imaging: Safety And Tolerability In Healthy Children And Cystic Fibrosis Patients
    Walkup, L. L.
    Thomen, R.
    Akinyi, T.
    Ruppert, K.
    Cleveland, Z. I.
    Clancy, J. P.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [27] MR spectroscopy of the dissolved phase of hyperpolarized Xe-129 in the human brain
    Brookeman, JR
    Mugler, JP
    Driehuys, B
    Phillips, CD
    Cates, GD
    Happer, W
    RADIOLOGY, 1997, 202 (02) : KH03 - KH03
  • [28] Measurement of pulmonary hematocrit using oscillation of hyperpolarized 129Xe MR signals in blood
    Liu, Xiaoling
    Li, Haidong
    Li, Hongchuang
    Zhang, Ming
    Zheng, Yu
    Zhao, Xiuchao
    Shi, Lei
    Han, Yeqing
    Guo, Fumin
    Zhou, Xin
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (05) : 1886 - 1895
  • [29] In vivo MR imaging and spectroscopy using hyperpolarized Xe-129
    Wagshul, ME
    Button, TM
    Li, HFF
    Liang, ZR
    Springer, CS
    Zhong, K
    Wishnia, A
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 183 - 191
  • [30] FUNCTIONAL ECHO-PLANAR MR IMAGING AT 1.0 T
    STEHLING, MK
    SCHMITT, F
    LADEBECK, R
    RADIOLOGY, 1992, 185 : 199 - 199