Mapping guided laser catheter ablation of the atrioventricular conduction in dogs

被引:5
|
作者
Weber, HP
Heinze, A
Enders, S
Ruprecht, L
Unsold, E
机构
[1] HARLACHING HOSP,DEPT MED 1,LASER UNIT,MUNICH,GERMANY
[2] UNIV MUNICH,TEACHING HOSP,BOGENHAUSEN HOSP,INST PATHOL,MUNICH,GERMANY
[3] GSF,LAB ANIM FACIL,OBERSCHLEISSHEIM,GERMANY
[4] GSF,CENT LASER LAB,OBERSCHLEISSHEIM,GERMANY
来源
关键词
atrioventricular conduction; catheter mapping; laser; ablation; supraventricular tachycardia;
D O I
10.1111/j.1540-8159.1996.tb03309.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Safety and efficacy of mapping guided laser catheter ablation of the AV junction was tested in a canine model. A total of 43 laser pulses (continuous wave, Nd:YAG, 1,064 nm, 30 W, irradiated spot diameter 2.0-2.5 mm) were delivered in 25 dogs (2-5 per dog) via a novel laser catheter system. Pulses were selectively aimed at: (1) She AV node; (2) the His bundle; and (3) the bundle branches, Laser pulses of 9.7 +/- 1.1 seconds (n = 31) produced reversible conduction disturbances in the targeted segment of the AV conduction system, while pulses of 28.6 +/- 7.9 seconds (n = 9) resulted in chronic block. The dogs survived the procedure without complications. Follow-up was 6.5-10.5 months. Histopathologically, lesions showed clear-cut oval-shaped areas of fibrosis of 0.5-18.0 mm in diameter and 0.5-3.5 mm (transmural) in depth, depending on the irradiation time, Pervenous mapping guided laser catheter irradiation of the AV junction can produce AV block consistently and selectively in the targeted segment of the right ventricular conduction system in dogs. The method is safe and can be performed in a controllable manner by using the catheter system presented.
引用
收藏
页码:176 / 187
页数:12
相关论文
共 50 条
  • [31] TRANS-VASCULAR ARGON-LASER ABLATION OF ATRIOVENTRICULAR-CONDUCTION IN DOGS - FEASIBILITY AND MORPHOLOGICAL RESULTS
    CURTIS, AB
    ABELA, GS
    GRIFFIN, JC
    HILL, JA
    NORMANN, SJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (02): : 347 - 357
  • [32] ENDOCARDIAL MAPPING AND RADIOFREQUENCY CATHETER ABLATION OF MULTIPLE ATRIOVENTRICULAR ACCESSORY PATHWAYS
    王乐信
    丁燕生
    胡大一
    Chinese Medical Journal, 1994, (02)
  • [33] CATHETER TECHNIQUE FOR CLOSED CHEST ABLATION OF THE ATRIOVENTRICULAR-CONDUCTION SYSTEM IN MAN
    GALLAGHER, JJ
    SVENSON, RH
    KASELL, JH
    GERMAN, LD
    BARDY, G
    BROUGHTON, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (04): : 1012 - 1012
  • [34] Radiofrequency catheter ablation of accessory atrioventricular pathways: Primary failure and recurrence of conduction
    Xie, B
    Heald, SC
    Camm, AJ
    Rowland, E
    Ward, DE
    HEART, 1997, 77 (04) : 363 - 368
  • [35] ENDOCARDIAL MAPPING AND RADIOFREQUENCY CATHETER ABLATION OF MULTIPLE ATRIOVENTRICULAR ACCESSORY PATHWAYS
    王乐信
    丁燕生
    胡大一
    中华医学杂志(英文版), 1994, (02) : 5 - 9
  • [36] ENDOCARDIAL MAPPING AND RADIOFREQUENCY CATHETER ABLATION OF MULTIPLE ATRIOVENTRICULAR ACCESSORY PATHWAYS
    WANG, LX
    DING, YS
    HU, DY
    CHINESE MEDICAL JOURNAL, 1994, 107 (02) : 83 - 87
  • [37] LOW-ENERGY PARTIAL ATRIOVENTRICULAR NODAL ABLATION USING SUCTION ABLATION CATHETER IN DOGS
    SINGER, I
    MALDONADO, C
    ACKERMANN, D
    KUPERSMITH, J
    CLINICAL RESEARCH, 1989, 37 (04): : A888 - A888
  • [38] CATHETER ABLATION OF THE ATRIOVENTRICULAR JUNCTION
    SCHEINMAN, MM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (04): : 1023 - 1023
  • [39] Modification of atrioventricular conduction in dogs by laser irradiation of Koch’s triangle guided by balloon-tipped cardioscope
    Kou Suzuki
    Kenzo Hirao
    Nobuo Toshida
    Naohito Yamamtoto
    Michio Tanaka
    Mitsuaki Isobe
    Journal of Interventional Cardiac Electrophysiology, 2009, 25 : 97 - 105
  • [40] CATHETER ABLATION IN ATRIOVENTRICULAR COMPLEX
    KAPPENBERGER, L
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1985, : 31 - 31