High-throughput analysis of telomerase by capillary electrophoresis

被引:21
|
作者
Atha, DH
Miller, K
Sanow, AD
Xu, JF
Hess, JL
Wu, OC
Wang, W
Srivastava, S
Highsmith, WE
机构
[1] NIST, Div Biotechnol, Gaithersburg, MD 20899 USA
[2] Natl Canc Inst, Div Canc Prevent, Rockville, MD USA
[3] Univ Maryland, Sch Med, Dept Pathol, Baltimore, MD 21201 USA
关键词
capillary electrophoresis; telomerase;
D O I
10.1002/elps.200390001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The enzyme telomerase is expressed in (85-90)% of all human cancers, but not in normal, non-stem cell somatic tissues. Clinical assays for telomerase in easily obtained body fluids would have great utility as noninvasive, cost-effective methods for the early detection of cancer. The most commonly used method for the detection and quantification of telomerase enzyme activity is the polymerase chain reaction (PCR)-based assay known as the telomerase repeat amplification protocol or TRAP assay. Most of the TRAP assay systems use a slab-gel based electrophoresis system to size and quantify the PCR-amplified extension products. We are developing high-throughput capillary electrophoresis (CE) methods for the analysis of TRAP/PCR products. The TRAP assay was conducted on lysates of the human lung cancer cell line A-549 in reactions containing 5-100 cells. TRAP/PCR products were generated using a fluorescent 4,7,2'4'5'7',-hexachloro-6-carboxyfluorescein(HEX)-labeled TS primer and analyzed on the Applied Biosystems Model 310 CE system using POP4(TM) polymer. After analysis with GeneScan(TM) and Genotyper(TM) software, the total peak areas of the TRAP ladder extension products were computed using Microsoft Excel(TM). Results were compared with unlabeled TRAP/PCR products analyzed on the Bio-Rad BioFocus 3000 CE system using 6% high molecular weight polyvinylpyrrolidone (HMW PVP) polymer and SYBR(TM) Green I dye. Both CE systems were able to resolve the TRAP ladder products with high reproducibility and sensitivity (5-15 cells). With the appropriate robotic sample handling system, these CE methods would enable performing the telomerase TRAP assay with increased sensitivity, reproducibility and automation over slab-gel methods.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [1] High-throughput TRAP/PCR analysis of telomerase using capillary electrophoresis
    Atha, DH
    Miller, K
    Sanow, AD
    Xu, J
    Hess, JL
    Wu, OC
    Wang, W
    Srivastava, S
    Highsmith, WE
    [J]. AMERICAN JOURNAL OF HUMAN GENETICS, 2002, 71 (04) : 230 - 230
  • [2] HiTRACE: high-throughput robust analysis for capillary electrophoresis
    Yoon, Sungroh
    Kim, Jinkyu
    Hum, Justine
    Kim, Hanjoo
    Park, Seunghyun
    Kladwang, Wipapat
    Das, Rhiju
    [J]. BIOINFORMATICS, 2011, 27 (13) : 1798 - 1805
  • [3] Automated high-throughput RNA analysis by capillary electrophoresis
    Khandurina, J
    Chang, HS
    Wanders, B
    Guttman, A
    [J]. BIOTECHNIQUES, 2002, 32 (06) : 1226 - +
  • [4] High-throughput capillary electrophoresis analysis of biopharmaceuticals utilizing sequential injections
    Kumar, Ramesh
    Sarin, Deepika
    Rathore, Anurag S. S.
    [J]. ELECTROPHORESIS, 2023, 44 (9-10) : 767 - 774
  • [5] High-Throughput Capillary-Electrophoresis Analysis of the Contents of a Single Mitochondria
    Allen, Peter B.
    Doepker, Byron R.
    Chiu, Daniel T.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (10) : 3784 - 3791
  • [6] High-throughput multiplexed capillary electrophoresis in drug discovery
    Pang, HM
    Kenseth, J
    Coldiron, S
    [J]. DRUG DISCOVERY TODAY, 2004, 9 (24) : 1072 - 1080
  • [7] High-throughput single-strand conformation polymorphism analysis by capillary electrophoresis
    Ren, JC
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (02): : 115 - 128
  • [8] High-throughput analysis of total RNA expression profiles by capillary gel electrophoresis
    Zhong, WW
    Yeung, ES
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (17) : 4415 - 4422
  • [9] Multiple-channel microchips for high-throughput DNA analysis by capillary electrophoresis
    Gao, QF
    Shi, YN
    Liu, SR
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (02): : 137 - 145
  • [10] Multiple-channel microchips for high-throughput DNA analysis by capillary electrophoresis
    Qiufeng Gao
    Yining Shi
    Shaorong Liu
    [J]. Fresenius' Journal of Analytical Chemistry, 2001, 371 : 137 - 145