Press-fit metal-backed rotating patella

被引:2
|
作者
Hartford, JM
Herfel, C
Kaufer, H
机构
[1] Univ Kentucky, Chandler Med Ctr, Kentucky Clin,Sch Med, Div Orthopaed Surg, Lexington, KY 40536 USA
[2] Vet Adm Med Ctr, Lexington, KY 40511 USA
关键词
D O I
10.1097/01.blo.0000022179.66847.7f
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A consecutive series of 80 patients with 110 press-fit metal-backed rotating platform patella resurfacing surgeries were reviewed at an average of 107 months followup (range, 84-167 months). Twenty-eight patients died before followup. Fifty-two patients (70 patellae) were available for clinical and radiographic followups. One patella was revised for failure of the patella component. Four patellae were revised along with revision of the knee replacement. One patella realignment procedure was done for recurrent subluxation of the patella. There were no patellar dislocations in this series, no patella fractures, and no disruption of the quadriceps tendon or infrapatellar ligament. Six patellae had subluxation seen on postoperative radiographs. The incidence of patellar tilt greater than 5degrees was 13%. No patellae were considered radiographically loose. The incidence of radiolucencies was 37%. Subsidence of the component superiorly was identified in 39% of the patellae, and inferiorly in 36% of the patellae. Of the 49 patients (67 knees) returning for followup, 70% of the knees were rated as excellent, 10% were rated good, 15% were rated fair, and 5% were rated poor. Press-fit metal-backed patella provided good component durability with only one revision because of component failure. Radiographic analyses showed a high incidence of subsidence associated with good clinical results.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
  • [41] PRESS-FIT PIN TECHNOLOGY FOR BELLPAC BACKPLANES
    EDWARDS, WJ
    HUDSON, GD
    [J]. WESTERN ELECTRIC ENGINEER, 1983, 27 (03): : 40 - 47
  • [42] Development of press-fit connector for automobile applications
    Basic Technology R and D Department, Circuits and Connection R and D Division, AutoNetworks Technologies, Ltd.
    不详
    [J]. SEI Tech Rev, 2006, 63 (33-39):
  • [43] Techniques to Remove Press-Fit Osseointegration Implants
    Ong, Germane
    Hoellwarth, Jason Shih
    Testworth, Kevin
    Al Muderis, Munjed
    [J]. JBJS ESSENTIAL SURGICAL TECHNIQUES, 2024, 14 (01):
  • [44] Press-fit hip arthroplasty - A European alternative
    Romagnoli, S
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (04): : 108 - 112
  • [45] The influence of bone damage on press-fit mechanics
    Bishop, Nicholas E.
    Hoehn, Jan-Christian
    Rothstock, Stephan
    Damm, Niklas B.
    Morlock, Michael M.
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (06) : 1472 - 1478
  • [46] THE PRESS-FIT IMPLANT IMPRESSION COPING TECHNIQUE
    Nissan, Joseph
    Ghelfan, Oded
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (06): : 413 - 414
  • [47] Ultrasonic quality control of press-fit joints
    Budenkov, G. A.
    Ivannikov, V. P.
    Kabakova, A. V.
    Strizhak, V. A.
    [J]. RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2009, 45 (08) : 575 - 581
  • [48] Plastic deformation of solderless press-fit connectors
    Manninen, T.
    Kanervo, K.
    Revuelta, A.
    Larkiola, J.
    Korhonen, A. S.
    [J]. MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2007, 460 : 633 - 637
  • [49] Training the Transmission Capacity of Press-Fit Connections
    Gropp, Herbert
    [J]. WELLE-NABE-VERBINDUNGEN: GESTALTUNG - FERTIGUNG - ANWENDUNGEN MIT FACHAUSSTELLUNG, 2012, 2012, 2176 : 19 - 29
  • [50] Arthroscopic ACL Reconstruction in Press-Fit Technique
    Halder, Andreas M.
    Marx, Axel
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2013, 28 (02) : 141 - 144