Cone-beam computed tomography of the head in standing equids

被引:15
|
作者
Bregger, M. D. Klopfenstein [1 ,2 ]
Koch, C. [1 ,2 ]
Zimmermann, R. [3 ]
Sangiorgio, D. [3 ]
Schweizer-Gorgas, D. [3 ]
机构
[1] Univ Bern, Vetsuisse Fac, Dept Clin Vet Med, Swiss Inst Equine Med ISME, Bern, Switzerland
[2] Agroscope, Bern, Switzerland
[3] Univ Bern, Vetsuisse Fac, Div Clin Radiol, Bern, Switzerland
关键词
Cone beam computed tomography; O-arm (R); Horse; Standing; Head;
D O I
10.1186/s12917-019-2045-z
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Computed tomography in standing horses has revolutionized diagnostic imaging. The O-arm (R), a cone beam computed tomography (CBCT) scanner with a gantry opening of 96.5 cm is routinely used for image-guided spine and neurosurgery in humans. The aim of this study is to describe the set-up and first experiences using the O-arm (R) to achieve CBCT imaging of the head in standing horses. CT imaging of the predefined region of interest (ROI) was tested on 2 cadaveric heads, concentrating on centering issues within the gantry, as well as determining the number of scans needed per ROI. All horses presented with head-related diseases and subjected to a CBCT examination between February 2015 and November 2016 for CBCT were included. Per scan, a limited field of view, i.e. a cylindrical volume of 21 cm in diameter and 16 cm in height was acquired within 13 s. Depending on the dimensions of the ROI, the minimum number of scans could range from one to six, if the entire equine head is to be examined in an adult horse. Results Sixty-eight horses were included, five of which had a follow-up CBCT exam, and two of which were presented twice for two different indications (75 clinical cases). A total number of 449 acquired three-dimensional (3D) scans were recorded for these 75 cases. Two-hundred and forty-two 3D scans (54%) were considered as diagnostic quality. The imaging procedure was generally well tolerated by the sedated, standing equid, and diagnostic studies were performed in 73 out of 75 cases (97.3%). Motion artefacts and inadequate centering of the ROI were the most common reasons for non-diagnostic quality images and repeat scans of the same ROI. Conclusions CBCT is a valuable imaging modality for the equine head. Advantages of the O-arm (R) compared to a conventional multi-slice helical CT for imaging of the head in standing equids include the rapid image acquisition, the gantry's mobility in all dimensions, and the free movability of the entire imaging unit. Disadvantages include the considerable sensitivity to motion artefact, increased scatter, low soft tissue contrast and the limited dimensions of the field of view.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Erdem, Sule
    Zengin, Ayse Zeynep
    Erdem, Suheda
    SURGICAL AND RADIOLOGIC ANATOMY, 2020, 42 (11) : 1307 - 1313
  • [42] Cone-Beam Computed Tomography and the Related Scientific Evidence
    Spagnuolo, Gianrico
    APPLIED SCIENCES-BASEL, 2022, 12 (14):
  • [43] Stability of voxel values in cone-beam computed tomography
    Munetaka Naitoh
    Hidetoshi Aimiya
    Kazuhiko Nakata
    Kenichi Gotoh
    Eiichiro Ariji
    Oral Radiology, 2014, 30 : 147 - 152
  • [44] Clinical guidelines for dental cone-beam computed tomography
    Hayashi, Takafumi
    Arai, Yoshinori
    Chikui, Toru
    Hayashi-Sakai, Sachiko
    Honda, Kazuya
    Indo, Hiroko
    Kawai, Taisuke
    Kobayashi, Kaoru
    Murakami, Shumei
    Nagasawa, Masako
    Naitoh, Munetaka
    Nakayama, Eiji
    Nikkuni, Yutaka
    Nishiyama, Hideyoshi
    Shoji, Noriaki
    Suenaga, Shigeaki
    Tanaka, Ray
    ORAL RADIOLOGY, 2018, 34 (02) : 89 - 104
  • [45] Assessing pulp stones by cone-beam computed tomography
    Nogueira Leal da Silva, Emmanuel Joao
    Prado, Marina C.
    Queiroz, Polyane M.
    Nejaim, Yuri
    Brasil, Danieli M.
    Groppo, Francisco Carlos
    Haiter-Neto, Francisco
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (07) : 2327 - 2333
  • [46] Essentials of Algebraic Reconstruction in Cone-Beam Computed Tomography
    A. E. Chernukha
    A. I. Shestopalov
    A. I. Adarova
    R. V. Shershnev
    Ya. V. Kizilova
    S. N. Koryakin
    S. A. Ivanov
    A. N. Solovev
    Bulletin of the Lebedev Physics Institute, 2023, 50 : 438 - 444
  • [47] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Şule Erdem
    Ayşe Zeynep Zengin
    Şuheda Erdem
    Surgical and Radiologic Anatomy, 2020, 42 : 1307 - 1313
  • [48] Motion Correction Algorithm for Cone-Beam Computed Tomography
    Lee, Jiyoung
    Kim, Jinwoo
    Cho, Minkook
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [49] Four curious cases of cone-beam computed tomography
    Mostafa, Yehya A.
    El-Beialy, Amr Ragab
    Omar, Gihan A.
    Fayed, Mona Salah
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S136 - S140
  • [50] Adult and pediatric cone-beam computed tomography dosimetries
    Molen, Aaron
    Paquette, David
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (02) : 125 - 125