Cone-beam computed tomography of the head in standing equids

被引:14
|
作者
Bregger, M. D. Klopfenstein [1 ,2 ]
Koch, C. [1 ,2 ]
Zimmermann, R. [3 ]
Sangiorgio, D. [3 ]
Schweizer-Gorgas, D. [3 ]
机构
[1] Univ Bern, Vetsuisse Fac, Dept Clin Vet Med, Swiss Inst Equine Med ISME, Bern, Switzerland
[2] Agroscope, Bern, Switzerland
[3] Univ Bern, Vetsuisse Fac, Div Clin Radiol, Bern, Switzerland
关键词
Cone beam computed tomography; O-arm (R); Horse; Standing; Head;
D O I
10.1186/s12917-019-2045-z
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Computed tomography in standing horses has revolutionized diagnostic imaging. The O-arm (R), a cone beam computed tomography (CBCT) scanner with a gantry opening of 96.5 cm is routinely used for image-guided spine and neurosurgery in humans. The aim of this study is to describe the set-up and first experiences using the O-arm (R) to achieve CBCT imaging of the head in standing horses. CT imaging of the predefined region of interest (ROI) was tested on 2 cadaveric heads, concentrating on centering issues within the gantry, as well as determining the number of scans needed per ROI. All horses presented with head-related diseases and subjected to a CBCT examination between February 2015 and November 2016 for CBCT were included. Per scan, a limited field of view, i.e. a cylindrical volume of 21 cm in diameter and 16 cm in height was acquired within 13 s. Depending on the dimensions of the ROI, the minimum number of scans could range from one to six, if the entire equine head is to be examined in an adult horse. Results Sixty-eight horses were included, five of which had a follow-up CBCT exam, and two of which were presented twice for two different indications (75 clinical cases). A total number of 449 acquired three-dimensional (3D) scans were recorded for these 75 cases. Two-hundred and forty-two 3D scans (54%) were considered as diagnostic quality. The imaging procedure was generally well tolerated by the sedated, standing equid, and diagnostic studies were performed in 73 out of 75 cases (97.3%). Motion artefacts and inadequate centering of the ROI were the most common reasons for non-diagnostic quality images and repeat scans of the same ROI. Conclusions CBCT is a valuable imaging modality for the equine head. Advantages of the O-arm (R) compared to a conventional multi-slice helical CT for imaging of the head in standing equids include the rapid image acquisition, the gantry's mobility in all dimensions, and the free movability of the entire imaging unit. Disadvantages include the considerable sensitivity to motion artefact, increased scatter, low soft tissue contrast and the limited dimensions of the field of view.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Cone-beam computed tomography of the head in standing equids
    M. D. Klopfenstein Bregger
    C. Koch
    R. Zimmermann
    D. Sangiorgio
    D. Schweizer-Gorgas
    [J]. BMC Veterinary Research, 15
  • [2] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    [J]. JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [3] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    [J]. DENTISTRY JOURNAL, 2019, 7 (03)
  • [4] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [6] Metal Artifact Reduction in Cone-Beam Computed Tomography for Head and Neck Radiotherapy
    Korpics, Mark
    Johnson, Paul
    Patel, Rakesh
    Surucu, Murat
    Choi, Mehee
    Emami, Bahman
    Roeske, John C.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : NP88 - NP94
  • [7] Evaluating the mandible with cone-beam computed tomography
    Stratemann, Scott A.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, Arthur J.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S58 - S70
  • [8] Simple ROI Cone-Beam Computed Tomography
    Maass, Clemens
    Knaup, Michael
    Sawall, Stefan
    Kachelriess, Marc
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3161 - 3168
  • [9] Cone-Beam Computed Tomography: Beyond Diagnostics
    Perel, Morton L.
    [J]. IMPLANT DENTISTRY, 2015, 24 (04) : 367 - 367
  • [10] Operational principles for cone-beam computed tomography
    Hatcher, David C.
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10): : 3S - 6S