Enhanced in-vitro blood compatibility of 316L stainless steel surfaces by reactive landing of hyaluronan ions

被引:32
|
作者
Volny, Michael
Elam, W. Timothy
Ratner, Buddy D.
Turecek, Frantisek
机构
[1] Univ Washington, Dept Chem, Seattle, WA 98195 USA
[2] Univ Washington, Appl Phys Lab, Seattle, WA 98195 USA
[3] Univ Washington Engn Biomat, Seattle, WA 98195 USA
关键词
reactive landing; sodium hyaluronan; haemocompatibility; surface immobilization; surface plasma treatment;
D O I
10.1002/jbm.b.30624
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel dry process for immobilization of hyaluronan on stainless steel surfaces is presented. This process that we call reactive landing is based on an interaction of hyperthermal gas-phase hyaluronan ions with plasma-cleaned and activated stainless steel surfaces. Reactive landing is performed on a unique instrument that combines an in-situ plasma reactor with an electrospray ion source and ion transfer optics. Gas-phase hyaluronan anions are obtained by electrospray ionization of sodium hyaluronan solutions and immobilized by reactive landing on large-area stainless steel surfaces. The immobilized hyaluronan withstands extensive washing with polar solvents and solutions, and the washed surfaces maintain the protective properties against blood platelet activation. The mechanism of hyaluronan discharge and immobilization is discussed. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 50 条
  • [21] Damage behavior of additive manufacturing 316L stainless steel irradiated with Fe ions
    Yang, Jinlei
    Fu, Chonglong
    Li, Jianjian
    Bai, Juju
    Lei, Qiantao
    Lin, Jun
    NUCLEAR MATERIALS AND ENERGY, 2024, 39
  • [22] Evaluation of Corrosion Inhibition of 316L Stainless Steel by Permanganate Ions in Chloride Solution
    Arbaoui, Fand
    Amzert, Sid Ahmed
    Boucherit, Mohamed Nadir
    Hanini, Salah
    Ghezali, Khaoula
    BULLETIN OF CHEMICAL REACTION ENGINEERING AND CATALYSIS, 2021, 16 (02): : 234 - 243
  • [23] The characterization of surfaces of electro polished 316L stainless steel for orthopedic implant applications
    Samide, A.
    Bibicu, I.
    Oprea, B.
    Cioatera, N.
    Ciuciu, A.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2008, 10 (06): : 1431 - 1436
  • [24] Preparation, Property and Blood Compatibility of Nanometer Silver Plating on 316L Steel Surface
    Xue Xin
    Fan Li-Shuang
    Niu Li
    Liu Bin
    Chang Jing
    Zhang Jing
    Zhang Ji-Chang
    Zhao Lei
    Zhao Zhuo
    Li Shu-Mei
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2012, 33 (10): : 2289 - 2294
  • [25] Production of Annealed Cold-Sprayed 316L Stainless Steel Coatings for Biomedical Applications and Their in-vitro Corrosion Response
    Dikici, Burak
    Topuz, Mehmet
    PROTECTION OF METALS AND PHYSICAL CHEMISTRY OF SURFACES, 2018, 54 (02) : 333 - 339
  • [26] Production of Annealed Cold-Sprayed 316L Stainless Steel Coatings for Biomedical Applications and Their in-vitro Corrosion Response
    Burak Dikici
    Mehmet Topuz
    Protection of Metals and Physical Chemistry of Surfaces, 2018, 54 : 333 - 339
  • [27] Study of in vitro anticoagulant property of the La added medical 316L stainless steel
    Yang Huajuan
    Yang Ke
    Zhang Bingchun
    ACTA METALLURGICA SINICA, 2006, 42 (09) : 959 - 964
  • [28] Study of in vitro anticoagulant property of the La added medical 316L stainless steel
    Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
    不详
    Jinshu Xuebao, 2006, 9 (959-964):
  • [29] Enhanced fatigue reliability analysis of additively manufactured 316L stainless steel components
    Cheng, Zhengwei
    Fang, Yongfeng
    Tee, Kong Fah
    AIP ADVANCES, 2025, 15 (03)
  • [30] THE SURFACE MODIFICATION OF 316L STAINLESS STEEL AND IN VITRO TESTS FOR CARDIOVASCULAR STENT APPLICATION
    Erdogan, Yasar Kemal
    Ercan, Batur
    TISSUE ENGINEERING PART A, 2022, 28 : S187 - S187