Segmentation of MRI brain scans using non-uniform partial volume densities

被引:41
|
作者
Brouwer, Rachel M. [1 ]
Pol, Hilleke E. Hulshoff [1 ]
Schnack, Hugo G. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Psychiat, Rudolf Magnus Inst Neurosci, NL-3508 GA Utrecht, Netherlands
关键词
MRI; Human brain; Segmentation; Partial volume effect; Non-uniform distribution; Reliability; Gray-white separation; MAGNETIC-RESONANCE IMAGES; ROBUST PARAMETER-ESTIMATION; TISSUE CLASSIFICATION; UNIFYING FRAMEWORK; WHITE-MATTER; VALIDATION; MODEL; REPRODUCIBILITY; RELIABILITY; ALGORITHMS;
D O I
10.1016/j.neuroimage.2009.07.041
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We present an algorithm that provides a partial volume segmentation of a T1-weighted image of the brain into gray matter, white matter and cerebrospinal fluid. The algorithm incorporates a non-uniform partial volume density that takes the curved nature of the cortex into account. The pure gray and white matter intensities are estimated from the image, using scanner noise and cortical partial volume effects. Expected tissue fractions are Subsequently computed in each voxel. The algorithm has been tested for reliability, correct estimation of the pure tissue intensities on both real (repeated) MRI data and on simulated (brain) images. Intra-class correlation coefficients (ICCs) were above 0.93 for all volumes of the three tissue types for repeated scans from the same scanner, as well as for scans with different voxel sizes from different scanners with different field strengths. The implementation of our non-uniform partial volume density provided more reliable volumes and tissue fractions, compared to a uniform partial volume density. Applying the algorithm to simulated images showed that the pure tissue intensities were estimated accurately. Variations in cortical thickness did not influence the accuracy of the Volume estimates, which is a valuable property when studying (possible) group differences. In conclusion, we have presented a new partial Volume segmentation algorithm that allows for comparisons over scanners and voxel sizes. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:467 / 477
页数:11
相关论文
共 50 条
  • [21] Segmentation of MRI brain scans using spatial constraints and 3D features
    Jonas Grande-Barreto
    Pilar Gómez-Gil
    Medical & Biological Engineering & Computing, 2020, 58 : 3101 - 3112
  • [22] Brain Tumor Segmentation in MRI Scans Using Deeply-Supervised Neural Networks
    Pourreza, Reza
    Zhuge, Ying
    Ning, Holly
    Miller, Robert
    BRAINLESION: GLIOMA, MULTIPLE SCLEROSIS, STROKE AND TRAUMATIC BRAIN INJURIES, BRAINLES 2017, 2018, 10670 : 320 - 331
  • [23] Novel whole brain segmentation and volume estimation using quantitative MRI
    West, J.
    Warntjes, J. B. M.
    Lundberg, P.
    EUROPEAN RADIOLOGY, 2012, 22 (05) : 998 - 1007
  • [24] Segmentation of MRI images to detect multiple sclerosis using non-parametric, non-uniform intensity normalization and support vector machine methods
    Moghadasi, Mohammad
    Fazekas, Gabor
    INFOCOMMUNICATIONS JOURNAL, 2021, 13 (01): : 68 - 74
  • [25] Novel whole brain segmentation and volume estimation using quantitative MRI
    J. West
    J. B. M. Warntjes
    P. Lundberg
    European Radiology, 2012, 22 : 998 - 1007
  • [26] LOCUS: LOcal cooperative unified segmentation of MRI brain scans
    Scherrer, B.
    Dojat, M.
    Forbes, F.
    Garbay, C.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 219 - +
  • [27] Dynamic adaptation of cooperative agents for MRI brain scans segmentation
    Richard, N
    Dojat, M
    Garbay, C
    ARTIFICIAL INTELLIGENCE IN MEDICINE, PROCEEDINGS, 2001, 2101 : 349 - 358
  • [28] MRF agent based segmentation: Application to MRI brain scans
    Scherrer, B.
    Dojat, M.
    Forbes, F.
    Garbay, C.
    ARTIFICIAL INTELLIGENCE IN MEDICINE, PROCEEDINGS, 2007, 4594 : 13 - 23
  • [29] Meningioma and peritumoral edema segmentation of preoperative MRI brain scans
    Binaghi, Elisabetta
    Pedoia, Valentina
    Balbi, Sergio
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2018, 6 (04): : 362 - 370
  • [30] Non-Uniform Dose Mapping Controlled by Modulated Vertical and Horizontal Scans
    Ninomiya, S.
    Kimura, Y.
    Kudo, T.
    Ochi, A.
    Toda, R.
    Tsukihara, M.
    Sato, F.
    Fuse, G.
    Ueno, K.
    Sugitani, M.
    ION IMPLANTATION TECHNOLOGY 2008, 2008, 1066 : 163 - +