Three-dimensional imaging of the aortic valve and aortic root with computed tomography: new standards in an era of transcatheter valve repair/implantation

被引:61
|
作者
Schoenhagen, Paul [1 ]
Tuzcu, E. Murat
Kapadia, Samir R.
Desai, Milind Y.
Svensson, Lars G.
机构
[1] Cleveland Clin, Imaging Inst, Cleveland, OH 44195 USA
关键词
Aortic root; Aortic valve; Percutaneous valve repair; Transcatheter aortic valve implantation; Multi-detector computed tomography; Three-dimensional imaging; VALVULAR HEART-DISEASE; EUROPEAN-SOCIETY; STENOSIS; IMPLANTATION; REPLACEMENT; PROSTHESIS; AREA; CT; QUANTIFICATION; CALCIFICATION;
D O I
10.1093/eurheartj/ehp260
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Valvular heart disease is a significant, global cause of morbidity and mortality. In the ageing population of industrialized nations, degenerative aortic stenosis has become the most common native valve disorder. Although surgical aortic valve replacement is associated with excellent clinical outcomes, a large number of patients with severe aortic stenosis are not considered surgical candidates. These patients have poor prognosis with continued medical therapy. In this population, catheter-based approaches for valve replacement/insertion show promising initial results. In an era of expanding catheter-based approaches to valve disease, the requirements for peri-operative imaging are evolving. Because of the lack of direct exposure during the procedure, the operator has to rely increasingly on imaging data rather than direct inspection. Novel three-dimensional (3D) imaging modalities, including computed tomography, rapidly acquire volumetric data sets and allow subsequent 3D display and reconstruction in unlimited planes. Procedural planning based on 3D imaging has already become routine for other endovascular procedures including aortic stent grafts, but is in its infancy in the context of transcatheter valve insertion.
引用
收藏
页码:2079 / 2086
页数:8
相关论文
共 50 条
  • [41] A novel three-dimensional imaging approach to evaluate coronary access before transcatheter aortic valve-in-valve implantation
    Khokhar, Arif A.
    Ponticelli, Francesco
    Zlahoda-Huzior, Adriana
    Ruggiero, Rossella
    Kim, Won-Keun
    Mangieri, Antonio
    Colombo, Antonio
    Dudek, Dariusz
    Giannini, Francesco
    EUROINTERVENTION, 2022, 17 (15) : 1238 - +
  • [42] Multidetector computed tomography evaluation of candidates for transcatheter aortic valve implantation
    Guillen Subiran, M. E.
    Ros Mendoza, L. H.
    Angulo Hervias, E.
    Yaguee Romeo, D.
    Nunez Motilva, M. E.
    RADIOLOGIA, 2018, 60 (01): : 24 - 38
  • [43] Feasibility of transcatheter aortic valve implantation evaluated by multislice computed tomography
    Von Bodman, G.
    Kreidel, F.
    Rampp, T.
    Vicol, C.
    Schmoeckel, M.
    Reichart, B.
    Kilger, E.
    Zwissler, B.
    Block, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 750 - 750
  • [44] Automated 3-Dimensional Aortic Annular Assessment by Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
    Watanabe, Yusuke
    Morice, Marie-Claude
    Bouvier, Erik
    Leong, Tora
    Hayashida, Kentaro
    Lefevre, Thierry
    Hovasse, Thomas
    Romano, Mauro
    Chevalier, Bernard
    Donzeau-Gouge, Patrick
    Farge, Arnaud
    Cormier, Bertrand
    Garot, Philippe
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (09) : 955 - 964
  • [45] Prosthesis sizing for transcatheter aortic valve implantation - Comparison of three dimensional transesophageal echocardiography with multislice computed tomography
    Husser, Oliver
    Holzamer, Andreas
    Resch, Markus
    Endemann, Dierk H.
    Nunez, Julio
    Bodi, Vicente
    Schmid, Christof
    Riegger, Guenter A. J.
    Goessmann, Holger
    Hamer, Okka
    Stroszczynski, Christian
    Luchner, Andreas
    Hilker, Michael
    Hengstenberg, Christian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 3431 - 3438
  • [46] Difficulties with horizontal aortic root in transcatheter aortic valve implantation
    Chan, Pak Hei
    Alegria-Barrero, Eduardo
    Di Mario, Carlo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (04) : 630 - 635
  • [47] Prosthesis sizing for transcatheter aortic valve implantation - Comparison of three dimensional transesophageal echocardiography with multislice computed tomography
    Husser, O.
    Holzamer, A.
    Nunez, J.
    Bodi, V.
    Schmid, C.
    Riegger, G. A. J.
    Hamer, O.
    Stroszczynski, C.
    Hilker, M.
    Hengstenberg, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 577 - 577
  • [48] Three-dimensional printing for assessment of paravalvular leak in transcatheter aortic valve implantation
    Casey Thorburn
    Omar Abdel-Razek
    Susan Fagan
    Neil Pearce
    Michael Furey
    Scott Harris
    Michael Bartellas
    Corey Adams
    Journal of Cardiothoracic Surgery, 15
  • [49] Three-Dimensional Blood Flow Alterations After Transcatheter Aortic Valve Implantation
    Markl, Michael
    Mikati, Issam
    Carr, James
    McCarthy, Patrick
    Malaisrie, S. Chris
    CIRCULATION, 2012, 125 (15) : E573 - E575
  • [50] Three-dimensional printing for assessment of paravalvular leak in transcatheter aortic valve implantation
    Thorburn, Casey
    Abdel-Razek, Omar
    Fagan, Susan
    Pearce, Neil
    Furey, Michael
    Harris, Scott
    Bartellas, Michael
    Adams, Corey
    JOURNAL OF CARDIOTHORACIC SURGERY, 2020, 15 (01)