High-pressure balloon catheter for real-time pressure monitoring in the Esophagus

被引:0
|
作者
Kwan, KY [1 ]
Kaler, KVIS [1 ]
Mintchev, M [1 ]
机构
[1] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
来源
ICES 2002: 9TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS I-111, CONFERENCE PROCEEDINGS | 2002年
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper reports the development of a new catheter for esophageal manometry, implemented by connecting a miniature high-pressure sensing balloon to an external pressure sensor. The integration of the catheter into a signal conditioning and data acquisition system for real-time pressure monitoring is also described. In order to characterize the sensitivity of the novel self-contained air balloon design, experimental setup for simulating the esophageal motility was utilized. The results show that the self-contained air balloon catheter is suitable for measuring various waveforms typical to the ones generated in esophageal motility pathologies.
引用
收藏
页码:1211 / 1214
页数:4
相关论文
共 50 条
  • [21] Real-Time Downhole Monitoring and Logging Reduced Mud Loss Drastically for High-Pressure Gas Wells in Tarim Basin, China
    Wang ShunChang
    Jiang YiMing
    Zheng ChunJiang
    Wu BaiLin
    Zheng XinQuan
    Tang JiPing
    Yu JinHai
    Fan HongHai
    SPE DRILLING & COMPLETION, 2010, 25 (02) : 187 - 192
  • [22] A REAL-TIME PRESSURE ALGORITHM
    KINIAS, P
    FOZZARD, HA
    NORUSIS, MJ
    COMPUTERS IN BIOLOGY AND MEDICINE, 1981, 11 (04) : 211 - 220
  • [23] A Wireless Power-Free Pressure Sensor for Real-Time In Vivo Gastrointestinal Pressure Monitoring
    Shi, Qiang
    Chen, Deyong
    Wang, Junbo
    Bao, Kaikai
    Liu, Lijuan
    MICRO-NANO TECHNOLOGY XV, 2014, 609-610 : 993 - 996
  • [24] Flexible Seven-in-One Microsensor Embedded in High-Pressure Proton Exchange Membrane Water Electrolyzer for Real-Time Microscopic Monitoring
    Lee, Chi-Yuan
    Chen, Chia-Hung
    Chuang, Hsian-Chun
    Chen, Shan-Yu
    Chiang, Yu-Chen
    SENSORS, 2023, 23 (12)
  • [25] THE HYPOGANGLIONIC AND AGANGLIONIC HIGH-PRESSURE ZONE AT THE MOUTH OF THE ESOPHAGUS
    STELZNER, F
    LIERSE, W
    MANNFRAHS, F
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1986, 367 (03): : 187 - 196
  • [26] Real-Time Monitoring of Blood Flow and Intravesical Pressure in the Rat Bladder
    Saito, Motoaki
    Ohmasa, Fumiya
    Tsounapi, Panagiota
    Inoue, Seiya
    Kinoshita, Yukako
    Dimitriadis, Fotios
    Satoh, Keisuke
    LUTS-LOWER URINARY TRACT SYMPTOMS, 2011, 3 (02) : 76 - 78
  • [27] Testbed for Real-time Monitoring of Leak in Low Pressure Gas Pipeline
    Mishra, Himanshu
    Karkulali, Pugalenthi
    Ukil, Abhisek
    Dauwels, Justin
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 459 - 462
  • [28] Calculation of the mean pressure with less delay for real-time clinical monitoring
    Ellis, Tim
    McNames, James
    Goldstein, Brahm
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2439 - +
  • [29] Improvement of longwall operation using real-time shield pressure monitoring
    Deb, D
    SITE CHARACTERISATION PRACTICE, 2000, : 475 - 481
  • [30] Development of a System for Real-Time Monitoring of Pressure, Temperature, and Humidity in Casts
    Tuan, Chiu-Ching
    Lu, Chi-Heng
    Wu, Yi-Chao
    Yeh, Wen-Ling
    Chen, Mei-Chuan
    Lee, Tsair-Fwu
    Chen, Yu-Jing
    Kao, Hsuan-Kai
    SENSORS, 2019, 19 (10):