High-pressure balloon catheter for real-time pressure monitoring in the Esophagus

被引:0
|
作者
Kwan, KY [1 ]
Kaler, KVIS [1 ]
Mintchev, M [1 ]
机构
[1] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper reports the development of a new catheter for esophageal manometry, implemented by connecting a miniature high-pressure sensing balloon to an external pressure sensor. The integration of the catheter into a signal conditioning and data acquisition system for real-time pressure monitoring is also described. In order to characterize the sensitivity of the novel self-contained air balloon design, experimental setup for simulating the esophageal motility was utilized. The results show that the self-contained air balloon catheter is suitable for measuring various waveforms typical to the ones generated in esophageal motility pathologies.
引用
收藏
页码:1211 / 1214
页数:4
相关论文
共 50 条
  • [1] DEVELOPMENT OF A PRESSURE SENSOR INTEGRATED INTO A CATHETER FOR REAL-TIME INTRAVECAL PRESSURE MONITORING
    Bae, W. J.
    Choi, J. B.
    Kim, K. S.
    Kim, S. J.
    Cho, H. J.
    Homg, S. H.
    Lee, Y. J.
    Hwang, T. K.
    Kim, S. W.
    JOURNAL OF SEXUAL MEDICINE, 2015, 12 : 403 - 403
  • [2] Embedded Based Real-Time Monitoring in the High-Pressure Resin Transfer Molding Process for CFRP
    Kim, Roh-Won
    Kim, Churl-Min
    Hwang, Kyung-Hwan
    Kim, Sung-Ryul
    APPLIED SCIENCES-BASEL, 2019, 9 (09):
  • [3] Benign tracheobronchial strictures: Treatment with high-pressure balloon catheter dilatation
    Lee, H
    Lee, K
    Lee, T
    Ko, GY
    Yoon, H
    Sung, K
    RADIOLOGY, 2000, 217 : 333 - 333
  • [4] Gas density sensor for real-time monitoring in a high pressure reactor
    Sell, J. K.
    Niedermayer, A. O.
    Babik, S.
    Jakoby, B.
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 108 - +
  • [5] Real-time monitoring of plasma flickering in high pressure electronegative discharge
    Kim, Yongjin
    Baek, Kyehyun
    Lee, Samhae
    Lee, Sungno
    Lee, Jaewook
    Jee, Yeonhong
    Kang, Changjin
    Cho, Hanku
    Moon, Jootae
    ISSM 2006 CONFERENCE PROCEEDINGS- 13TH INTERNATIONAL SYMPOSIUM ON SEMICONDUCTOR MANUFACTURING, 2006, : 346 - 349
  • [6] Real-time data acquisition inside high-pressure PEM water electrolyzer
    Lee, Chi -Yuan
    Chen, Chia-Hung
    Chuang, Sheng-Ming
    Dai, Ching-Liang
    Lai, Bo-Jui
    Chen, Shan-Yu
    Hsu, Jia-Yu
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 372
  • [7] Establishment of a Real-Time Simulation of a Marine High-Pressure Common Rail System
    Wang, Qinpeng
    Yao, Heming
    Yu, Yonghua
    Yang, Jianguo
    He, Yuhai
    ENERGIES, 2021, 14 (17)
  • [8] Intracoronary stent implantation using a single high-pressure perfusion balloon catheter
    Waksman, R
    Shafer, CD
    Seung, KB
    Shen, YN
    Weintraub, WS
    King, SB
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1997, 40 (02): : 140 - 143
  • [9] Endocanalicular, High-Pressure Balloon Catheter, Endoscopic Dacryocystorhinostomy: A Randomized Controlled Trial
    Ragab, Sameh M.
    El-Koddousy, Mona S.
    Badr, Mohammed
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2011, 145 (04) : 683 - 688
  • [10] Implantable Biosensors for Real-time Strain and Pressure Monitoring
    Tan, Ee Lim
    Pereles, Brandon D.
    Horton, Brock
    Shao, Ranyuan
    Zourob, Mohammed
    Ong, Keat Ghee
    SENSORS, 2008, 8 (10) : 6396 - 6406