First X-ray imaging with a micromachined Wolter type-I telescope

被引:10
|
作者
Ogawa, Tomohiro [1 ]
Ezoe, Yuichiro [1 ]
Kakiuchi, Takuya [1 ]
Ikuta, Masahiro [1 ]
Sato, Mayu [1 ]
Nakamura, Kasumi [1 ]
Numazawa, Masaki [1 ]
Takeuchi, Kazuma [1 ]
Terada, Masaru [1 ]
Ohashi, Takaya [1 ]
Mitsuishi, Ikuyuki [2 ]
Ishikawa, Kumi [3 ]
Mitsuda, Kazuhisa [4 ]
Morishita, Kohei [5 ]
Nakajima, Kazuo [6 ]
机构
[1] Tokyo Metropolitan Univ, 1-1 Minami Osawa, Hachioji, Tokyo 1920397, Japan
[2] Nagoya Univ, Nagoya, Aichi, Japan
[3] RIKEN, Wako, Saitama, Japan
[4] ISAS JAXA, Sagamihara, Kanagawa, Japan
[5] Kyoto Univ, Kyoto, Japan
[6] Tohoku Univ, Sendai, Miyagi, Japan
关键词
OPTICS; SYSTEM;
D O I
10.1007/s00542-016-2906-3
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A light-weight Wolter type-I telescope for future space X-ray observations is prototyped by using micromachining technologies. Curvilinear micro pores with a width of 20 m are fabricated with deep reactive ion etching. Sidewalls of the pores are smoothed with high temperature annealing. Then, two wafers are deformed to different curvature radii, 1000 and 333 mm. The two wafers are aligned using parallel X-ray beams which are dominated by Al-K line at 1.49 keV. High angular and positional accuracies of the order of arcsec and m are achieved using movable stages. The first clear X-ray focusing is confirmed. Its angular resolution is 4.1 arcmin in full width half maximum while it is at least 92 arcmin in half power width. The effective area is 19.0 mm which is 5 times smaller than a model calculation. We discuss causes of the degraded angular resolution and effective area and also future improvements.
引用
收藏
页码:1101 / 1116
页数:16
相关论文
共 50 条
  • [21] Characterizing curved surface roughness of Wolter-I X-ray grazing incidence telescope
    Zhang Ya-chao
    Liu Peng
    Wang Xiao-guang
    He Ling-ping
    Chen Bo
    CHINESE OPTICS, 2019, 12 (03): : 587 - 595
  • [22] A generalized Wolter Type I design for the solar X-ray imager (SXI)
    Harvey, JE
    Thompson, PL
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS II, 1999, 3766 : 173 - 183
  • [23] Effects of the coating optimization on the field of view for a Wolter X-ray telescope
    Cotroneo, V.
    Pareschi, G.
    Spiga, D.
    Tagliaferri, G.
    SPACE TELESCOPES AND INSTRUMENTATION 2010: ULTRAVIOLET TO GAMMA RAY, 2010, 7732
  • [24] Systems engineering analysis of aplanatic Wolter type I x-ray telescopes
    Thompson, PL
    Harvey, JE
    OPTICAL ENGINEERING, 2000, 39 (06) : 1677 - 1691
  • [25] Wolter type I x-ray focusing mirror using multilayer coatings
    Chon, Kwon Su
    Namba, Yoshiharu
    Yoon, Kwon-Ha
    APPLIED OPTICS, 2006, 45 (19) : 4609 - 4616
  • [26] Figure error measurement method of cylindrical reflection mirror for conic approximate Wolter-I X-ray type telescope
    Liu N.
    Shen Z.
    Ma B.
    Wei Z.
    Xu X.
    Wang Z.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2018, 47 (04):
  • [27] Simulation of a Typical Wolter-I X-ray Telescope Using the Geant4 Toolkit
    Abbasian Motlagh Mehdi
    Rastegarzadeh Gohar
    Instruments and Experimental Techniques, 2023, 66 : 451 - 455
  • [28] Simulation of a Typical Wolter-I X-ray Telescope Using the Geant4 Toolkit
    Mehdi, Abbasian Motlagh
    Gohar, Rastegarzadeh
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2023, 66 (03) : 451 - 455
  • [30] GEOMETRIC ABERRATION OF A GENERALIZED WOLTER TYPE-I TELESCOPE .2. ANALYTICAL STUDY
    NARIAI, K