Pericoronary adipose tissue attenuation assessed by dual-layer spectral detector computed tomography is a sensitive imaging marker of high-risk plaques

被引:31
|
作者
Chen, Xujiao [1 ]
Dang, Yuxue [1 ]
Hu, Hong [1 ]
Ma, Shaowei [2 ]
Ma, Yue [1 ]
Wang, Kunhua [3 ]
Liu, Ting [4 ]
Lu, Xiaomei [5 ]
Hou, Yang [1 ]
机构
[1] China Med Univ, Radiol Dept, Shengjing Hosp, Shenyang, Peoples R China
[2] China Med Univ, Dept Cardiol, Shengjing Hosp, Shenyang, Peoples R China
[3] Peoples Hosp Liaoning Prov, Radiol Dept, Shenyang, Peoples R China
[4] China Med Univ, Radiol Dept, Affiliated Hosp 1, Shenyang, Peoples R China
[5] Philips Healthcare, CT Clin Sci, Shenyang, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual-layer spectral detector computed tomography (dual-layer SDCT); pericoronary adipose tissue (PCAT); high-risk plaque; computed tomography attenuation (CT attenuation); CORONARY ATHEROSCLEROSIS; INFLAMMATION; CT; ANGIOGRAPHY; QUANTIFICATION; ASSOCIATION; ACCURACY; VOLUME;
D O I
10.21037/qims-20-860
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The pericoronary fat attenuation index (FAI) derived from conventional polychromatic computed tomography (CT) can capture the presence of coronary inflammation. However, conventional polychromatic CT has limitations in material component differentiation, and spectral CT could have a better ability to discriminate tissue characteristics. Hence, this study sought to assess pericoronary adipose tissue (PCAT) attenuation using spectral CT and explore its association with atherosclerotic plaque characteristics. Methods: We enrolled 104 patients with coronary atherosclerosis who met the inclusion criteria and underwent coronary CT angiography with dual-layer spectral detector computed tomography (SDCT). Plaque anatomical characteristics were measured, and the PCAT attenuation was assessed by polychromatic images (CTpoly), virtual mono-energetic images at 40 keV (CT40 keV), the slope of spectral attenuation curve (lambda(HU)), and the effective atomic number (Z(eff)). The association of PCAT attenuation indicators with the presence of high-risk plaques was analyzed, along with the indicators' ability to identify high-risk plaques. Results: PCAT attenuation indicators around high-risk plaques were higher than those around non-high-risk plaques, especially CT40 keV [-153.76 +/- 24.97 (non-high-risk plaque) vs. -119.87 +/- 22.74 (high-risk plaque), P<0.001]. CT40 keV was a predictive factor of high-risk plaques, and high CT40 keV (>=-120.60 HU) could assist in the identification of high-risk plaques, with an area under the curve of 0.883 (95% CI: 0.83-0.94, P<0.05). Conclusions: PCAT surrounding high-risk plaques showed higher attenuation; a finding that has been associated with coronary artery inflammation. The metrics derived from SDCT, especially CT40 keV, showed higher discriminatory power for detecting changes in PCAT attenuation than polychromatic CT. PCAT attenuation assessed by CT40 keV may provide a novel imaging marker of plaque vulnerability.
引用
收藏
页码:2093 / 2103
页数:11
相关论文
共 50 条
  • [21] Quantitative analysis of late iodine enhancement using dual-layer spectral detector computed tomography: comparison with magnetic resonance imaging
    Liu, Peijun
    Lin, Lu
    Xu, Cheng
    Han, Yechen
    Lin, Xue
    Hou, Yang
    Lu, Xiaomei
    Vembar, Mani
    Jin, Zhengyu
    Wang, Yining
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 310 - 320
  • [22] Computed tomography-based pericoronary adipose tissue attenuation in patients undergoing TAVR: a novel method for risk assessment
    Steyer, Alexandra
    Mas-Peiro, Silvia
    Leistner, David M.
    Puntmann, Valentina O.
    Nagel, Eike
    Dey, Damini
    Goeller, Markus
    Koch, Vitali
    Booz, Christian
    Vogl, Thomas J.
    Martin, Simon S.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [23] CORONARY INFLAMMATION ASSESSED BY PERICORONARY ADIPOSE TISSUE ATTENUATION ON COMPUTED TOMOGRAPHY ANGIOGRAPHY PREDICTS ATRIAL FIBRILLATION RECCURENCE AFTER CRYOBALLOON ABLATION
    Nogami, Kai
    Sugiyama, Tomoyo
    Kanaji, Yoshihisa
    Hoshino, Masahiro
    Yamaguchi, Masao
    Hada, Masahiro
    Sumino, Yohei
    Misawa, Toru
    Hirano, Hidenori
    Ueno, Hiroki
    Kakuta, Tsunekazu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1809 - 1809
  • [24] Dynamic evaluation of myocardial extracellular volume fraction using dual-layer spectral detector computed tomography
    Kidoh, Masafumi
    Oda, Seitaro
    Takashio, Seiji
    Tsujita, Kenichi
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2020, 4 (06)
  • [25] Dual-layer spectral detector computed tomography multiparameter machine learning model for prediction of invasive lung adenocarcinoma
    Wan, Jiayu
    Lin, Xue
    Wang, Zhaokai
    Sun, Peng
    Gui, Shen
    Ye, Tianhe
    Fan, Qianqian
    Liu, Weiwei
    Pan, Feng
    Yang, Bo
    Geng, Xiaotong
    Quan, Zhen
    Yang, Lian
    TRANSLATIONAL LUNG CANCER RESEARCH, 2025, 14 (02)
  • [26] Application of dual-layer spectral detector computed tomography to evaluate the expression of Ki-67 in colorectal cancer
    Wang, Yu-Li
    Zhang, Han-Wen
    Mo, Yong-Qian
    Zhong, Hua
    Liu, Wei-Ming
    Lei, Yi
    Lin, Fan
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2022, 85 (05) : 610 - 616
  • [27] Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading
    Mu, Ronghua
    Meng, Zhuoni
    Guo, Zixuan
    Qin, Xiaoyan
    Huang, Guangyi
    Yang, Xuri
    Jin, Hui
    Yang, Peng
    Zhang, Xiaodi
    Zhu, Xiqi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, : 4601 - 4611
  • [28] Fat Quantification in Dual-Layer Detector Spectral Computed Tomography Experimental Development and First In-Patient Validation
    Molwitz, Isabel
    Campbell, Graeme Michael
    Yamamura, Jin
    Knopp, Tobias
    Toedter, Klaus
    Fischer, Roland
    Wang, Zhiyue Jerry
    Busch, Alina
    Ozga, Ann-Kathrin
    Zhang, Shuo
    Lindner, Thomas
    Sevecke, Florian
    Grosser, Mirco
    Adam, Gerhard
    Szwargulski, Patryk
    INVESTIGATIVE RADIOLOGY, 2022, 57 (07) : 463 - 469
  • [29] Usefulness and limitations of dual-layer spectral detector computed tomography for diagnosing biliary stones not detected by conventional computed tomography: a report of three cases
    Saito H.
    Noda K.
    Ogasawara K.
    Atsuji S.
    Takaoka H.
    Kajihara H.
    Nasu J.
    Morishita S.
    Matsushita I.
    Katahira K.
    Clinical Journal of Gastroenterology, 2018, 11 (2) : 172 - 177
  • [30] A Retrospectively Study: Diagnosis of Pathological Types of Malignant Lung Tumors by Dual-layer Detector Spectral Computed Tomography
    Ma, Xia
    Xu, Ming
    Tian, Xiao-Juan
    Liu, Yong-Li
    Zhang, Xin-Ri
    Qiao, Ying
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21