Non-invasive fetal lung assessment using diffusion-weighted imaging

被引:8
|
作者
Lee, W. [1 ,3 ,4 ]
Krisko, A. [1 ]
Shetty, A. [2 ]
Yeo, L. [3 ,4 ]
Hassan, S. S. [3 ,4 ]
Gotsch, F. [3 ]
Mody, S. [5 ]
Goncalves, L. F. [3 ,4 ]
Romero, R. [3 ,4 ,6 ]
机构
[1] William Beaumont Hosp, Div Fetal Imaging, Dept Obstet & Gynecol, Royal Oak, MI 48073 USA
[2] William Beaumont Hosp, Res Inst, Dept Diagnost Radiol, Royal Oak, MI 48073 USA
[3] NICHD, Perinatol Res Branch, NIH, DHHS, Bethesda, MD USA
[4] Wayne State Univ, Dept Obstet & Gynecol, Detroit, MI 48202 USA
[5] Wayne State Univ, Dept Pediat Imaging, Detroit, MI 48202 USA
[6] Wayne State Univ, Sch Med, Ctr Mol Med & Genet, Detroit, MI 48202 USA
关键词
diffusion-weighted imaging; fetus; lung; magnetic resonance imaging; PRELIMINARY EXPERIENCE; IN-VIVO; COEFFICIENT; MRI; BRAIN; DIAGNOSIS; KIDNEYS;
D O I
10.1002/uog.7446
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives The main goal was to develop a reproducible method for estimating the diffusion of water in human fetal lung tissue using diffusion-weighted imaging (DWI). A secondary objective was to determine the relationship of the apparent diffusion coefficients (ADCs) in the fetal lung to menstrual age and total lung volume. Methods Normal pregnant volunteers were scanned on a 1.5-Tesla (T) magnetic resonance imaging (MRI) system. The MRI system was equipped with 40-mT/m gradients (slew rate 200 T/m/s, rise time 0.2 ms). A six-channel body array coil was used for signal reception. Single-shot DWI utilized TE/TR 125/3400 ms, slice thickness 4 mm, field of view 280 mm x 280 mm, interstice gap 0.8 mm and a matrix of 128 x 128. The voxel size was 2.5 mm x 2.5 mm x 4.0 mm. Two b-values (0 and 1000) were chosen along three orthogonal directions. ADC maps were created using assigned b-values. Simple linear regression was performed with Pearson correlation coefficient. Interexaminer and intraexaminer bias, and 95% limits of agreement (LOA) were determined using Bland-Altman plots. Results Forty-seven scans were performed at a mean +/- SD of 29.2 +/- 4.5 weeks. The median coefficient of variation for A DC was 5.6% (interquartile range, 4.0-8.1%). No differences in A DC values were found between right and left lungs. Normally distributed ADC measurements were not significantly correlated with either total lung volume (r(2) = 0.0001, P = 0.94) or menstrual age (r(2) = 0.003, P = 0.70). The mean ADC value was 1.75 (95% CI, 1.63-1.86). Mean +/- SD intraexaminer bias was -0.15 +/- 2.3 (95% LOA, -4.7 to +4.4) and interexaminer bias was 2.2 +/- 3.5 (95% LOA, -4.7 to +9.1). Conclusions Our findings suggest that ADC measurements of the fetal lung are reproducible between blinded examiners and are independent of menstrual age, as well as lung volume. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:673 / 677
页数:5
相关论文
共 50 条
  • [31] Value of Diffusion-Weighted Imaging in Assessment of Liver Lesions
    Hussien, Radwan A.
    Dombroski, D.
    Rubens, D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [32] Diffusion-weighted imaging in the assessment of brain abscesses therapy
    Cartes-Zumelzu, FW
    Stavrou, I
    Castillo, M
    Eisenhuber, E
    Knosp, E
    Thurnher, MM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (08) : 1310 - 1317
  • [33] Non-invasive assessment of hepatic fibrosis: comparison of MR elastography to transient elastography and intravoxel incoherent motion diffusion-weighted MRI
    Fu, Fangfang
    Li, Xiaodong
    Chen, Cuiyun
    Bai, Yan
    Liu, Qiuyu
    Shi, Dapeng
    Sang, Jia
    Wang, Kaiyu
    Wang, Meiyun
    ABDOMINAL RADIOLOGY, 2020, 45 (01) : 73 - 82
  • [34] Application of MR diffusion imaging for non-invasive assessment of acute kidney injury after lung transplantation
    Derlin, Katja
    Hellms, Susanne
    Gutberlet, Marcel
    Peperhove, Matti
    Jang, Mi-Sun
    Greite, Robert
    Hartung, Dagmar
    Derlin, Thorsten
    Fegbeutel, Christine
    Tudorache, Igor
    Juettner, Bjorn
    Wiese, Birgitt
    Lichtinghagen, Ralf
    Haller, Hermann
    Haverich, Axel
    Wacker, Frank
    Warnecke, Gregor
    Gueler, Faikah
    MEDICINE, 2020, 99 (49) : E22445
  • [35] Non-invasive assessment of hepatic fibrosis: comparison of MR elastography to transient elastography and intravoxel incoherent motion diffusion-weighted MRI
    Fangfang Fu
    Xiaodong Li
    Cuiyun Chen
    Yan Bai
    Qiuyu Liu
    Dapeng Shi
    Jia Sang
    Kaiyu Wang
    Meiyun Wang
    Abdominal Radiology, 2020, 45 : 73 - 82
  • [36] Diffusion-Weighted Imaging and Diffusion Tensor Imaging
    Raya J.G.
    Current Radiology Reports, 2 (3)
  • [37] Diffusion-weighted magnetic resonance imaging for assessment of lung lesions: repeatability of the apparent diffusion coefficient measurement
    L. Bernardin
    N. H. M. Douglas
    D. J. Collins
    S. L. Giles
    E. A. M. O’Flynn
    M. Orton
    N. M. deSouza
    European Radiology, 2014, 24 : 502 - 511
  • [38] Diffusion-weighted magnetic resonance imaging for assessment of lung lesions: repeatability of the apparent diffusion coefficient measurement
    Bernardin, L.
    Douglas, N. H. M.
    Collins, D. J.
    Giles, S. L.
    O'Flynn, E. A. M.
    Orton, M.
    deSouza, N. M.
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 502 - 511
  • [39] Diffusion-weighted imaging in the assessment of cervical cancer: comparison of reduced field-of-view diffusion-weighted imaging and conventional techniques
    He, Yakun
    Wang, Min
    Yi, Siqi
    Lu, Yujie
    Ren, Jing
    Zhou, Peng
    Xu, Ke
    ACTA RADIOLOGICA, 2023, 64 (08) : 2485 - 2491
  • [40] Diffusion weighted imaging as a non-invasive marker in an experimental model of lymph node metastasis
    Klerkx, Wenche M.
    Geldof, Ab A.
    Heintz, Peter M.
    Takahara, Taro
    Mali, Willem M.
    Veldhuis, Wouter B.
    CLINICAL & EXPERIMENTAL METASTASIS, 2009, 26 (07) : 910 - 911