Multiple-slice imaging of a tissue-equivalent phantom by use of time-resolved optical tomography

被引:37
|
作者
Schmidt, FEW
Hebden, JC
Hillman, EMC
Fry, ME
Schweiger, M
Dehghani, H
Delpy, DT
Arridge, SR
机构
[1] Royal Postgrad Med Sch, Dept Med Phys, London WC1E 6JA, England
[2] UCL, Dept Comp Sci, London WC1E 6BT, England
关键词
D O I
10.1364/AO.39.003380
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Following several years of development the construction of a multichannel time-resolved imaging device for medical optical tomography has been completed. Images are reconstructed from time-resolved measurements by use of a scheme that employs a finite-element diffusion-based forward model and an iterative reconstruction solver. Prior to testing on clinical subjects the fully automated instrument and the reconstruction software are evaluated with tissue-equivalent phantoms. We describe our first attempt to generate multiple-slice images of a phantom without uniform properties along the axial direction, while still using a computationally fast two-dimensional reconstruction algorithm. The image quality is improved by the employment of an approximate correction method that uses scaling factors derived from the ratios of finite-element forward simulations in two and three spatial dimensions. The 32-channel system was employed to generate maps of the internal scattering and the absorption properties at 14 different transverse planes across the phantom. The images clearly reveal the locations of small inhomogeneous regions embedded within the phantom. These results were obtained by use of purely temporal data and without resource to reference measurements. (C) 2000 Optical Society of America OCIS codes: 170.3010, 170.6920, 170.6960, 170.0110.
引用
收藏
页码:3380 / 3387
页数:8
相关论文
共 50 条
  • [21] Time-resolved fluorescent imaging in tissue.
    Hattery, D
    Chernomordik, V
    Loew, M
    Gannot, I
    Gandjbakhche, A
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 384 - 391
  • [22] Breast tissue-equivalent contrast detail, resolution and dosimetry phantom for 3D imaging
    Ja, T
    Da, S
    Romanyukna, A
    Tomon, JJ
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 584 - 586
  • [23] Time-resolved optical spectroscopy and imaging of breast
    Taroni, P
    Pifferi, A
    Torricelli, A
    Cubeddu, R
    OPTO-ELECTRONICS REVIEW, 2004, 12 (02) : 249 - 253
  • [24] Multiple-slice magnetic resonance imaging can detect visceral adipose tissue reduction more accurately than single-slice imaging
    So, R.
    Sasai, H.
    Matsuo, T.
    Tsujimoto, T.
    Eto, M.
    Saotome, K.
    Tanaka, K.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2012, 66 (12) : 1351 - 1355
  • [25] The UCL multichannel time-resolved system for optical tomography
    Wells, K
    Hebden, JC
    Schmidt, FEW
    Delpy, DT
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF, 1997, 2979 : 599 - 607
  • [26] An optimized engineering design of imaging probe for time-resolved diffuse optical tomography system
    Chen, Ling
    Hasnain, Ali
    Chen, Nanguang
    OPTICAL SENSORS AND BIOPHOTONICS III, 2011, 8311
  • [27] Multiple-slice magnetic resonance imaging can detect visceral adipose tissue reduction more accurately than single-slice imaging
    R So
    H Sasai
    T Matsuo
    T Tsujimoto
    M Eto
    K Saotome
    K Tanaka
    European Journal of Clinical Nutrition, 2012, 66 : 1351 - 1355
  • [28] An optimized engineering design of imaging probe for time-resolved diffuse optical tomography system
    Chen, Ling
    Hasnain, Ali
    Chen, Nanguang
    2011 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE AND EXHIBITION (ACP), 2012,
  • [29] Time-resolved imaging on a realistic tissue phantom: mu(s)' and mu(a) images versus time-integrated images
    Cubeddu, R
    Pifferi, A
    Taroni, P
    Torricelli, A
    Valentini, G
    APPLIED OPTICS, 1996, 35 (22) : 4533 - 4540
  • [30] Improvement of image quality in diffuse optical tomography by use of full time-resolved data
    Gao, F
    Zhao, HJ
    Yamada, Y
    APPLIED OPTICS, 2002, 41 (04) : 778 - 791