Fibrous Cap Thickness by Optical Coherence Tomography In Vivo

被引:58
|
作者
Kini, Annapoorna S. [1 ,2 ]
Vengrenyuk, Yuliya [1 ,2 ]
Yoshimura, Takahiro [1 ,2 ]
Matsumura, Mitsuaki [3 ,4 ]
Pena, Jacobo [1 ,2 ]
Baber, Usman [1 ,2 ]
Moreno, Pedro [1 ,2 ]
Mehran, Roxana [1 ,2 ]
Maehara, Akiko [3 ,4 ]
Sharma, Samin [1 ,2 ]
Narula, Jagat [1 ,2 ]
机构
[1] Mt Sinai Hosp, Div Cardiol, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, New York, NY 10029 USA
[3] Columbia Univ, Med Ctr, Div Cardiol, New York, NY USA
[4] Cardiovasc Res Fdn, New York, NY USA
关键词
atherosclerosis; interobserver variability; optical coherence tomography; thin-cap fibroatheroma; PLAQUE MORPHOLOGY; CORONARY-DISEASE; CLASSIFICATION; OCT; ACQUISITION; VALIDATION; AGREEMENT; ACCURACY; ARTERIES;
D O I
10.1016/j.jacc.2016.10.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Optical coherence tomography (OCT) imaging is considered to be the only imaging modality with sufficient resolution to measure fibrous cap thickness (FCT) in vivo. However, reproducibility of the measurements in vivo has been unsatisfactory. OBJECTIVES The authors aimed to investigate whether satisfactory reproducibility of FCT measurements by OCT in vivo can be achieved between independent observers. METHODS One hundred seventy OCT pullbacks were analyzed by 2 independent observers with intravascular imaging expertise in accordance with current guidelines to assess the interobserver variability of FCT measurement by intraclass correlation coefficient (ICC). The main sources of the variability were analyzed and incorporated in lesion assessment criteria. The same 170 OCT pullbacks were reanalyzed by the same observers using the developed criteria, and the interobserver reproducibility of the measurements was reassessed. On the basis of the developed criteria, a third independent observer interpreted all 170 OCT images. Assessment of the maximal lipid arc was also undertaken similarly before and after the development of interpretation criteria. RESULTS The original ICC of the FC thickness was 0.56 (95% confidence interval [ CI]: 0.38 to 0.69). The poor definition of necrotic core facing border of FC and the neointimal presence of macrophages and calcification contributed to the high interobserver variability of FCT measurement. The ICC of FCT measurements by OCT in vivo was 0.88 (95% CI: 0.80 to 0.93) after we developed lesion assessment criteria. The ICC for the maximal lipid arc assessment before and after was 0.76 and 0.82 respectively. The third independent observer was extensively coached and returned the ICC of 0.82 (95% CI: 0.74 to 0.87) with observer 1 and 0.90 (95% CI: 0.86 to 0.94) with observer 2. CONCLUSIONS Careful consideration of OCT features mimicking fibroatheroma lesions and imaging artifacts contributed to significantly higher levels of interobserver agreement. Interobserver variation can be partially resolved by development of standard interpretation algorithms. (C) 2017 by the American College of Cardiology Foundation.
引用
下载
收藏
页码:644 / 657
页数:14
相关论文
共 50 条
  • [21] Comparison between different approaches to evaluate fibrous cap thickness in sequential optical coherence tomography studies
    Romagnoli, Enrico
    Paoletti, Giulia
    Marco, Valeria
    Gatto, Laura
    Calligaris, Giuseppe
    Fabbiocchi, Franco
    Fineschi, Massimo
    Boi, Alberto
    Albertucci, Mario
    Nicholls, Stephen J.
    Prati, Francesco
    MINERVA CARDIOLOGY AND ANGIOLOGY, 2023, 71 (03) : 275 - 283
  • [22] Statin Therapy and Change in Fibrous Cap Thickness: Meta-Analysis of Optical Coherence Tomography Assessment
    Kanmanthareddy, Arun
    Anugula, Dixitha
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B220 - B220
  • [23] Assessment of fibrous cap thickness of the coronary plaque by optical coherence tomography: Comparison with coronary angioscopic image
    Kubo, Takashi
    Masyo, Takashi
    Yamano, Takashi
    Takarada, Shigeho
    Imanishi, Toshio
    Tomobuchi, Yoshiaki
    Akasaka, Takashi
    CIRCULATION, 2006, 114 (18) : 646 - 646
  • [24] Quantification of fibrous cap thickness in intracoronary optical coherence tomography with a contour segmentation method based on dynamic programming
    Zahnd, Guillaume
    Karanasos, Antonios
    van Soest, Gijs
    Regar, Evelyn
    Niessen, Wiro
    Gijsen, Frank
    van Walsum, Theo
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (09) : 1383 - 1394
  • [25] Relationship between plasma inflammatory markers and plaque fibrous cap thickness determined by intravascular optical coherence tomography
    Li, Q-X
    Fu, Q-Q
    Shi, S-W
    Wang, Y-F
    Xie, J-J
    Yu, X.
    Cheng, X.
    Liao, Y-H
    HEART, 2010, 96 (03) : 196 - 201
  • [26] In coronary culprit lesions fibrous cap thickness but not calcification is associated with the presence of diabetes: an optical coherence tomography study
    Milzi, A.
    Burgmaier, M.
    Marx, N.
    Reith, S.
    EUROPEAN HEART JOURNAL, 2016, 37 : 866 - 867
  • [27] Evaluation of Fibrous Cap Thickness by Optical Coherence Tomography for Positive Remodeling and Low Attenuation Plaques Assessed by Computed Tomography Angiography
    Sato, Akira
    Hoshi, Tomoya
    Kakefuda, Yuki
    Ojima, Eiji
    Adachi, Toru
    Watabe, Hiroaki
    Aonuma, Kazutaka
    CIRCULATION, 2011, 124 (21)
  • [28] Quantification of fibrous cap thickness in intracoronary optical coherence tomography with a contour segmentation method based on dynamic programming
    Guillaume Zahnd
    Antonios Karanasos
    Gijs van Soest
    Evelyn Regar
    Wiro Niessen
    Frank Gijsen
    Theo van Walsum
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1383 - 1394
  • [29] Impact of Eicosapentaenoic Acid Treatment on the Fibrous Cap Thickness in Patients with Coronary Atherosclerotic Plaque: An Optical Coherence Tomography Study
    Yamano, Takashi
    Kubo, Takashi
    Shiono, Yasutsugu
    Shimamura, Kunihiro
    Orii, Makoto
    Tanimoto, Takashi
    Matsuo, Yoshiki
    Ino, Yasushi
    Kitabata, Hironori
    Yamaguchi, Tomoyuki
    Hirata, Kumiko
    Tanaka, Atsushi
    Imanishi, Toshio
    Akasaka, Takashi
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2015, 22 (01) : 52 - 61
  • [30] Effect of Statin Therapy on Fibrous Cap Thickness in Coronary Plaque on Optical Coherence Tomography - Review and Meta-Analysis -
    Ozaki, Yuichi
    Garcia-Garcia, Hector M.
    Beyene, Solomon S.
    Hideo-Kajita, Alexandre
    Kuku, Kayode O.
    Kolm, Paul
    Waksman, Ron
    CIRCULATION JOURNAL, 2019, 83 (07) : 1480 - +