Fibrous Cap Thickness by Optical Coherence Tomography In Vivo

被引:57
|
作者
Kini, Annapoorna S. [1 ,2 ]
Vengrenyuk, Yuliya [1 ,2 ]
Yoshimura, Takahiro [1 ,2 ]
Matsumura, Mitsuaki [3 ,4 ]
Pena, Jacobo [1 ,2 ]
Baber, Usman [1 ,2 ]
Moreno, Pedro [1 ,2 ]
Mehran, Roxana [1 ,2 ]
Maehara, Akiko [3 ,4 ]
Sharma, Samin [1 ,2 ]
Narula, Jagat [1 ,2 ]
机构
[1] Mt Sinai Hosp, Div Cardiol, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, New York, NY 10029 USA
[3] Columbia Univ, Med Ctr, Div Cardiol, New York, NY USA
[4] Cardiovasc Res Fdn, New York, NY USA
关键词
atherosclerosis; interobserver variability; optical coherence tomography; thin-cap fibroatheroma; PLAQUE MORPHOLOGY; CORONARY-DISEASE; CLASSIFICATION; OCT; ACQUISITION; VALIDATION; AGREEMENT; ACCURACY; ARTERIES;
D O I
10.1016/j.jacc.2016.10.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Optical coherence tomography (OCT) imaging is considered to be the only imaging modality with sufficient resolution to measure fibrous cap thickness (FCT) in vivo. However, reproducibility of the measurements in vivo has been unsatisfactory. OBJECTIVES The authors aimed to investigate whether satisfactory reproducibility of FCT measurements by OCT in vivo can be achieved between independent observers. METHODS One hundred seventy OCT pullbacks were analyzed by 2 independent observers with intravascular imaging expertise in accordance with current guidelines to assess the interobserver variability of FCT measurement by intraclass correlation coefficient (ICC). The main sources of the variability were analyzed and incorporated in lesion assessment criteria. The same 170 OCT pullbacks were reanalyzed by the same observers using the developed criteria, and the interobserver reproducibility of the measurements was reassessed. On the basis of the developed criteria, a third independent observer interpreted all 170 OCT images. Assessment of the maximal lipid arc was also undertaken similarly before and after the development of interpretation criteria. RESULTS The original ICC of the FC thickness was 0.56 (95% confidence interval [ CI]: 0.38 to 0.69). The poor definition of necrotic core facing border of FC and the neointimal presence of macrophages and calcification contributed to the high interobserver variability of FCT measurement. The ICC of FCT measurements by OCT in vivo was 0.88 (95% CI: 0.80 to 0.93) after we developed lesion assessment criteria. The ICC for the maximal lipid arc assessment before and after was 0.76 and 0.82 respectively. The third independent observer was extensively coached and returned the ICC of 0.82 (95% CI: 0.74 to 0.87) with observer 1 and 0.90 (95% CI: 0.86 to 0.94) with observer 2. CONCLUSIONS Careful consideration of OCT features mimicking fibroatheroma lesions and imaging artifacts contributed to significantly higher levels of interobserver agreement. Interobserver variation can be partially resolved by development of standard interpretation algorithms. (C) 2017 by the American College of Cardiology Foundation.
引用
收藏
页码:644 / 657
页数:14
相关论文
共 50 条
  • [1] In vivo, Raptured Plaque Fibrous Cap Thickness Assessed by Optical Coherence Tomography
    Kakita, Ken
    Kakuta, Tsunekazu
    Yonetsu, Taishi
    Lee, Tetsumin
    Takayama, Kai
    Takahashi, Kentaro
    Yamamoto, Ginga
    [J]. CIRCULATION, 2009, 120 (18) : S953 - S953
  • [2] Measurement of the thickness of the fibrous cap by optical coherence tomography
    Kume, Teruyoshi
    Akasaka, Takashi
    Kawamoto, Takahiro
    Okura, Hiroyuki
    Watanabe, Nozomi
    Toyota, Eiji
    Neishi, Yoji
    Sukmawan, Renan
    Sadahira, Yoshito
    Yoshida, Kiyoshi
    [J]. AMERICAN HEART JOURNAL, 2006, 152 (04) : 755.e1 - 755.e4
  • [3] Significance of fibrous cap thickness measured by optical coherence tomography.
    Takeda, Y
    Suzuki, T
    Tsuchikane, E
    Itoh, T
    Ehara, M
    Sato, H
    Matsubara, T
    Shigenori, I
    Katoh, O
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 142E - 142E
  • [4] IN VIVO REPRODUCIBILITY OF MEASUREMENTS FOR FIBROUS CAP THICKNESS AND LIPID ARC IN LIPID PLAQUES BY OPTICAL COHERENCE TOMOGRAPHY
    Kim, Soo-Joong
    Lee, Hang
    Kato, Koji
    Yonetsu, Taishi
    Xing, Lei
    Zhang, Shaosong
    Jang, Ik-Kyung
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1438 - E1438
  • [5] Optical Coherence Tomography and Fibrous Cap Characterization
    Chamié D.
    Wang Z.
    Bezerra H.
    Rollins A.M.
    Costa M.A.
    [J]. Current Cardiovascular Imaging Reports, 2011, 4 (4) : 276 - 283
  • [6] Assessment of fibrous cap by optical coherence tomography
    Kume, T
    Akasaka, T
    Kawamoto, T
    Toyota, E
    Neishi, Y
    Sukmawan, R
    Saito, K
    [J]. CIRCULATION, 2005, 112 (17) : U679 - U679
  • [7] In vivo critical fibrous cap thickness for rupture-prone coronary plaques assessed by optical coherence tomography
    Yonetsu, Taishi
    Kakuta, Tsunekazu
    Lee, Tetsumin
    Takahashi, Kentaro
    Kawaguchi, Naohiko
    Yamamoto, Ginga
    Koura, Kenji
    Hishikari, Keiichi
    Iesaka, Yoshito
    Fujiwara, Hideomi
    Isobe, Mitsuaki
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 (10) : 1251 - 1259
  • [8] In vivo characterization of fibrous cap rupture in coronary plaques by optical coherence tomography
    Yonetsu, T.
    Kakuta, T.
    Lee, T.
    Takahashi, K.
    Kawaguchi, N.
    Yamamoto, G.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 299 - 299
  • [9] An Automated Computational Method for Quantification of Total Fibrous Cap Volume and Mean Fibrous Cap Thickness with Optical Coherence Tomography
    Woo, Vincent
    Chen, Zhi
    Hirai, Taishi
    Weber, Joseph R.
    Kovarnik, Tomas
    Wahle, Andreas
    Sonka, Milan
    Lopez, John J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B143 - B144
  • [10] New insights into fibrous cap thickness of vulnerable plaques assessed by optical coherence tomography
    Liu, Xianglan
    He, Wujian
    Hong, Xulin
    Li, Duanbin
    Chen, Zhezhe
    Wang, Yao
    Chen, Zhaoyang
    Luan, Yi
    Zhang, Wenbin
    [J]. BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)