Scenarios-based energy dispatching of PVG/Battery/Grid-connected installation

被引:1
|
作者
Guidara, Imen [1 ,2 ]
Souissi, Anoir [1 ,2 ]
Chaabene, Maher [1 ,2 ]
机构
[1] CRNS, Sfax, Tunisia
[2] SIME, Sfax, Tunisia
关键词
energy management; grid-connected PVG; grid connected PVG with storage; self-consumption; SELF-CONSUMPTION; OPTIMIZATION; GENERATION; SYSTEMS; MODEL;
D O I
10.1109/irec.2019.8754590
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In most grid -connected photovoltaic standard installations, the generated energy is consumed by the user and in case of excess or lack the grid intervene to either absorb energy or cover the need. Such strategy involves limitations as blackout while grid failure and grid pollution with inverters harmonics. This paper proposes a novel approach that considers the grid as a complementary source to avoid the grid -connected photovoltaic system problems. An algorithm is developed to manage energy flows of a PVG/Battery/Grid installation by minimizing the grid connection for load supply. In addition, a continuous supply of the load is guaranteed even while grid failure. The proposed strategy aims to increase the self -consumption, to avoid grid pollution and to keep saving the battery from an excessive charge and discharge. Obtained results confirm a continuous load supply during stable day as well as perturbed day and an improvement of the installation self -consumption.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Optimal Energy for Grid-Connected Microgrid with Battery Swapping Station and Wind Photovoltaic and Energy Storage
    Song, Jiaoru
    Suo, Lian
    [J]. PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 1469 - 1473
  • [42] A Grid-connected Battery Charger with Power Factor Correction
    Hung, Chih-Yi
    Wu, Jinn-Chang
    Chen, Yong-Lin
    Jou, Hurng-Liahng
    [J]. PROCEEDINGS OF THE 2016 IEEE 11TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2016, : 1446 - 1452
  • [43] Optimal sizing of a lithium battery energy storage system for grid-connected photovoltaic systems
    Dulout, Jeremy
    Jammes, Bruno
    Alonso, Corinne
    Anvari-Moghaddam, Amjad
    Luna, Adriana
    Guerrero, Josep M.
    [J]. 2017 IEEE SECOND INTERNATIONAL CONFERENCE ON DC MICROGRIDS (ICDCM), 2017, : 582 - 587
  • [44] Bidirectional Single-Stage Grid-Connected Inverter for a Battery Energy Storage System
    Lo, Kuo-Yuan
    Chen, Yaow-Ming
    Chang, Yung-Ruei
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (06) : 4581 - 4590
  • [45] Exploring emerging battery technology for grid-connected energy storage with Constructive Technology Assessment
    Versteeg, T.
    Baumann, M. J.
    Weil, M.
    Moniz, A. B.
    [J]. TECHNOLOGICAL FORECASTING AND SOCIAL CHANGE, 2017, 115 : 99 - 110
  • [46] Optimal Sizing of Battery Energy Storage for a Grid-Connected Microgrid Subjected to Wind Uncertainties
    Abdulgalil, Mohammed Atta
    Khalid, Muhammad
    Alismail, Fahad
    [J]. ENERGIES, 2019, 12 (12)
  • [47] Filter Design for Grid-Connected Multilevel CHB Inverter for Battery Energy Storage Systems
    Lahlou, Taha
    Abdelrahem, Mohamed
    Valdes, Susana
    Herzog, Hans-Georg
    [J]. 2016 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2016, : 825 - 830
  • [48] Energy Trading in Grid-connected PV-Battery Electric Vehicle Charging Station
    Erick, Arwa O.
    Folly, Komla A.
    [J]. 2020 INTERNATIONAL SAUPEC/ROBMECH/PRASA CONFERENCE, 2020, : 190 - 195
  • [49] Optimal operation of a grid-connected battery energy storage system over its lifetime
    Kordonis, Ioannis
    Charalampidis, Alexandros C.
    Haessig, Pierre
    [J]. OPTIMAL CONTROL APPLICATIONS & METHODS, 2023, 44 (02): : 739 - 757
  • [50] A Quadratic Programming Based Optimal Power and Battery Dispatch for Grid-Connected Microgrid
    Paul, Tim George
    Hossain, Sheikh J.
    Ghosh, Sudipta
    Mandal, Paras
    Kamalasadan, Sukumar
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (02) : 1793 - 1805