Time-Resolved Diffusion Detection with Microstopped Flow System

被引:5
|
作者
Nakasone, Yusuke [1 ]
Takaramoto, Shunki [1 ]
Terazima, Masahide [1 ]
机构
[1] Kyoto Univ, Grad Sch Sci, Dept Chem, Kyoto 6068502, Japan
关键词
INTERMOLECULAR INTERACTION; ARABIDOPSIS PHOTOTROPIN-1; DYNAMICS; LOV2; BINDING; DOMAIN;
D O I
10.1021/acs.analchem.9b02897
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The transient grating (TG) method is a powerful technique for monitoring the time dependence of the diffusion coefficient during photochemical reactions. However, the applications of this technique have been limited to photochemical reactions. Here, a microstopped flow (mu-SF) system is developed to expand the technique's applicability. The constructed mu-SF system can be used for a solution with a total volume as small as 3 mu L, and mixing times for absorption and diffusion measurements were determined to be 400 mu s and 100 ms, respectively. To demonstrate this system with the TG method, an acid-induced denaturation of a photosensor protein, phototropin LOV2 domain with a linker, was studied from the viewpoint of the reactivity. This system can be used not only for time-resolved diffusion measurement but also for conventional absorption or fluorescence detection methods. In particular, this system has a great advantage for a target solution in that only a very small amount is needed.
引用
收藏
页码:11987 / 11993
页数:7
相关论文
共 50 条
  • [31] Time-resolved spectroscopic mapping of vibrational energy flow in proteins: Understanding thermal diffusion at the nanoscale
    Mizutani, Yasuhisa
    Mizuno, Misao
    JOURNAL OF CHEMICAL PHYSICS, 2022, 157 (24):
  • [32] A Time-Resolved Diffusion Technique for Detection of the Conformational Changes and Molecular Assembly/Disassembly Processes of Biomolecules
    Nakasone, Yusuke
    Terazima, Masahide
    FRONTIERS IN GENETICS, 2021, 12
  • [33] A compact time-resolved system for NIR spectroscopy
    Re, Rebecca
    Contini, Davide
    Caffini, Matteo
    Spinelli, Lorenzo
    Cubeddu, Rinaldo
    Torricelli, Alessandro
    CLINICAL AND BIOMEDICAL SPECTROSCOPY, 2009, 7368
  • [34] A simplified system for reading time-resolved photoluminescence
    Yasuda, H
    Ishidoya, T
    JOURNAL OF RADIATION RESEARCH, 2002, 43 : S63 - S65
  • [35] Miniaturized Time-Resolved Fluorescence Spectroscopy System
    Gasser, Anas
    Shcheglov, Artem
    Lapauw, Thomas
    van den Dries, Thomas
    Ingelberts, Hans
    Hoving, Willem
    Aalders, Maurice
    Kuijk, Maarten
    PHOTONIC INSTRUMENTATION ENGINEERING IX, 2022, 12008
  • [36] Time-resolved measurement system of electrofluorescence spectra
    Tsushima, M
    Ushizaka, T
    Ohta, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (02): : 479 - 485
  • [37] The ULTRA Laser System - For Time-Resolved Spectroscopy
    Parker, Anthony
    XXII INTERNATIONAL CONFERENCE ON RAMAN SPECTROSCOPY, 2010, 1267 : 68 - 68
  • [38] The time-resolved natural flow field of a fluidic oscillator
    Woszidlo, Rene
    Ostermann, Florian
    Nayeri, C. N.
    Paschereit, C. O.
    EXPERIMENTS IN FLUIDS, 2015, 56 (06)
  • [39] The time-resolved natural flow field of a fluidic oscillator
    Rene Woszidlo
    Florian Ostermann
    C. N. Nayeri
    C. O. Paschereit
    Experiments in Fluids, 2015, 56
  • [40] Evaluating integrin activation with time-resolved flow cytometry
    Sambrano, Jesus, Jr.
    Chigaev, Alexandre
    Nichani, Kapil S.
    Smagley, Yelena
    Sklar, Larry A.
    Houston, Jessica P.
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (07)