A thorough performance assessment of solar chimney power plants: Case study for Manzanares

被引:17
|
作者
Cuce, Erdem [1 ,2 ]
Cuce, Pinar Mert [2 ,3 ]
Sen, Harun [1 ,2 ]
机构
[1] Recep Tayyip Erdogan Univ, Fac Engn, Dept Mech Engn, Zihni Derin Campus, TR-53100 Rize, Turkey
[2] Recep Tayyip Erdogan Univ, Fac Engn, Low Zero Carbon Energy Technol Lab, Zihni Derin Campus, TR-53100 Rize, Turkey
[3] Recep Tayyip Erdogan Univ, Fac Engn, Dept Energy Syst Engn, Zihni Derin Campus, TR-53100 Rize, Turkey
来源
关键词
Solar chimney; CFD; Solar radiation; Atmospheric temperature; Optimum operation;
D O I
10.1016/j.clet.2020.100026
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar chimney power plants (SCPPs) are promising systems for clean energy generation. SCPPs are ideal for the large-scale harnessing of solar energy. They operate efficiently without auxiliary energy and do not cause any environmental pollution. There are several theoretical, numerical and experimental attempts to date for performance assessment of SCPPs, however, there are still contradictions in the findings, and a thorough performance evaluation is still missing. Therefore, in this study, a novel three-dimensional axisymmetric computational fluid dynamics (CFD) approach is proposed by considering the pioneer plant in Manzanares region. For a realistic approach, actual geometric parameters of the pilot plant are utilised in the CFD model, and the performance assessments are done regardless of time. Pressure, temperature and velocity distributions within the SCPP from collector inlet to chimney outlet are numerically modelled with respect to changes in solar radiation and atmospheric temperature. For model validation, the numerical findings are compared with the typical experimental findings performed in pilot plant, and a good agreement is obtained. For a certain value of solar radiation (1000 W/m(2)), maximum air velocity in the pilot plant is found to be 14.24 m/s, which is compatible with the experimental data of 15.00 m/s. Static pressure is found to sharply decrease from chimney ground to turbine inlet, and then steadily rises to the chimney outlet. Minimum static pressure is observed to be similar to 100.18 Pa at 21.92 m from the ground. Output power of SCPP linearly increases with the solar intensity whereas it steadily reduces with ambient temperature. Available power is determined to be 49059 W for the case of 1000 W/m(2), and the atmospheric temperature of 293 K.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Implementation of active and passive control strategies for power generation in a solar chimney power plant: A technical evaluation of Manzanares prototype
    Torkfar, Arman
    Arefian, Amir
    Hosseini-Abardeh, Reza
    Bahrami, Mohsen
    [J]. RENEWABLE ENERGY, 2023, 216
  • [42] Numerical Simulation and Comparison of Conventional and Sloped Solar Chimney Power Plants: The Case for Lanzhou
    Cao, Fei
    Li, Huashan
    Zhang, Yang
    Zhao, Liang
    [J]. SCIENTIFIC WORLD JOURNAL, 2013,
  • [43] ANN and CFD driven research on main performance characteristics of solar chimney power plants: Impact of chimney and collector angle
    Cuce, Pinar Mert
    Cuce, Erdem
    Mandal, Dipak Kumar
    Gayen, Dilip Kumar
    Asif, Muhammad
    Bouabidi, Abdallah
    Alshahrani, Saad
    Prakash, Chander
    Soudagar, Manzoore Elahi M.
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2024, 60
  • [44] Solar chimney power plant performance in Iran
    Asnaghi, A.
    Ladjevardi, S. M.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (05): : 3383 - 3390
  • [45] Performance Study Of Solar Chimney Power Plant System With A Sloped Collector
    Li, Qingling
    Fan, Xiyan
    Xin, Xuan
    Chao, Jun
    Zhou, Yan
    [J]. ADVANCED POLYMER PROCESSING III, 2013, 561 : 597 - +
  • [46] Study on the Performance of a solar chimney power plant Chlef, Algeria region
    Nouar, Hadda
    Tahri, Toufik
    Chiba, Younes
    [J]. PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE ON APPLIED SMART SYSTEMS (ICASS), 2018,
  • [47] Performance assessment of solar chimney power plants with natural thermal energy storage materials on ground: CFD analysis with experimental validation
    Cuce, Erdem
    Saxena, Abhishek
    Cuce, Pinar Mert
    Sen, Harun
    Eroglu, Hasan
    Selvanathan, Shanmuga Priya
    Sudhakar, Kumarasamy
    Hasanuzzaman, Md
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2022, 17 : 752 - 759
  • [48] MAGNUS-EFFECT ROTORS FOR SOLAR CHIMNEY POWER PLANTS
    Serag-Eldin, Mohamed A.
    Latif, Mohammed A. Abdul
    [J]. PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE - 2010 - VOL 1, PTS A-C, 2010, : 819 - 828
  • [49] A Comparative Study of CFD Models of a Real Wind Turbine in Solar Chimney Power Plants
    Gholamalizadeh, Ehsan
    Chung, Jae Dong
    [J]. ENERGIES, 2017, 10 (10):
  • [50] Counter-rotating turbines for solar chimney power plants
    Denantes, F.
    Bilgen, E.
    [J]. RENEWABLE ENERGY, 2006, 31 (12) : 1873 - 1891