A thorough performance assessment of solar chimney power plants: Case study for Manzanares

被引:17
|
作者
Cuce, Erdem [1 ,2 ]
Cuce, Pinar Mert [2 ,3 ]
Sen, Harun [1 ,2 ]
机构
[1] Recep Tayyip Erdogan Univ, Fac Engn, Dept Mech Engn, Zihni Derin Campus, TR-53100 Rize, Turkey
[2] Recep Tayyip Erdogan Univ, Fac Engn, Low Zero Carbon Energy Technol Lab, Zihni Derin Campus, TR-53100 Rize, Turkey
[3] Recep Tayyip Erdogan Univ, Fac Engn, Dept Energy Syst Engn, Zihni Derin Campus, TR-53100 Rize, Turkey
来源
关键词
Solar chimney; CFD; Solar radiation; Atmospheric temperature; Optimum operation;
D O I
10.1016/j.clet.2020.100026
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar chimney power plants (SCPPs) are promising systems for clean energy generation. SCPPs are ideal for the large-scale harnessing of solar energy. They operate efficiently without auxiliary energy and do not cause any environmental pollution. There are several theoretical, numerical and experimental attempts to date for performance assessment of SCPPs, however, there are still contradictions in the findings, and a thorough performance evaluation is still missing. Therefore, in this study, a novel three-dimensional axisymmetric computational fluid dynamics (CFD) approach is proposed by considering the pioneer plant in Manzanares region. For a realistic approach, actual geometric parameters of the pilot plant are utilised in the CFD model, and the performance assessments are done regardless of time. Pressure, temperature and velocity distributions within the SCPP from collector inlet to chimney outlet are numerically modelled with respect to changes in solar radiation and atmospheric temperature. For model validation, the numerical findings are compared with the typical experimental findings performed in pilot plant, and a good agreement is obtained. For a certain value of solar radiation (1000 W/m(2)), maximum air velocity in the pilot plant is found to be 14.24 m/s, which is compatible with the experimental data of 15.00 m/s. Static pressure is found to sharply decrease from chimney ground to turbine inlet, and then steadily rises to the chimney outlet. Minimum static pressure is observed to be similar to 100.18 Pa at 21.92 m from the ground. Output power of SCPP linearly increases with the solar intensity whereas it steadily reduces with ambient temperature. Available power is determined to be 49059 W for the case of 1000 W/m(2), and the atmospheric temperature of 293 K.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A thorough performance assessment of solar chimney power plants: Case study for Manzanares (vol 1, 100026, 2020)
    Cuce, E.
    [J]. CLEANER ENGINEERING AND TECHNOLOGY, 2022, 7
  • [2] Numerical performance modelling of solar chimney power plants: Influence of chimney height for a pilot plant in Manzanares, Spain
    Cuce, Erdem
    Sen, Harun
    Cuce, Pinar Mert
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 39
  • [3] Performance assessment of solar chimney power plants with the impacts of divergent and convergent chimney geometry
    Cuce, Erdem
    Saxena, Abhishek
    Cuce, Pinar Mert
    Sen, Harun
    Guo, Shaopeng
    Sudhakar, K.
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (03) : 704 - 714
  • [4] Effect of chimney shadow on the performance of wind supercharged solar chimney power plants: A numerical case study for the Spanish prototype
    Lu Zuo
    Pengzhan Dai
    Ling Ding
    Ziyang Yan
    Xinru Wang
    Jiachen Li
    [J]. Global Energy Interconnection, 2021, 4 (04) : 405 - 414
  • [5] Effect of chimney shadow on the performance of wind supercharged solar chimney power plants: A numerical case study for the Spanish prototype
    Zuo, Lu
    Dai, Pengzhan
    Ding, Ling
    Yan, Ziyang
    Wang, Xinru
    Li, Jiachen
    [J]. GLOBAL ENERGY INTERCONNECTION-CHINA, 2021, 4 (04): : 405 - 414
  • [6] Case study of solar chimney power plants in Northwestern regions of China
    Dai, YJ
    Huang, HB
    Wang, RZ
    [J]. RENEWABLE ENERGY, 2003, 28 (08) : 1295 - 1304
  • [7] Performance evaluation of solar chimney power plants in Iran
    Sangi, Roozbeh
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (01): : 704 - 710
  • [8] Performance of divergent-chimney solar power plants
    Xu, Yangyang
    Zhou, Xinping
    [J]. SOLAR ENERGY, 2018, 170 : 379 - 387
  • [9] Performance Assessment of Solar Thermal Power Plants: A Case Study in Queensland
    Shah, Rakibuzzaman
    Yan, Ruifeng
    Saha, Tapan Kumar
    [J]. 2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [10] A NUMERICAL study of solar chimney power plants in Tunisia
    Bahar, Attig F.
    Guellouz, M. S.
    Sahraoui, M.
    Kaddeche, S.
    [J]. TUNISIA-JAPAN SYMPOSIUM: R&D OF ENERGY AND MATERIAL SCIENCES FOR SUSTAINABLE SOCIETY, 2015, 596