In-tube solid-phase microextraction coupled to capillary LC for carbamate analysis in water samples

被引:67
|
作者
Gou, YN [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Guelph Waterloo Ctr Grad Work Chem, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac990726h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently, the on-line sample preparation technique, in tube solid-phase microextraction (SPME), was successfully implemented with a Hewlett-Packard 1100 HPLC system for analysis of carbamates in water samples. This paper describes the coupling of in-tube SPME to capillary LC and explores its utility as a sample preparation method in that format, relative to conventional LC, The Hewlett-Packard HPLC system was upgraded to a capillary LC system using commercially available accessories from LC Packings. The combination of in-tube SPME with a capillary LC system was expected to build on the merits of both in-tube SPME and the capillary LC to generate a sensitive method with an easy, effective, and efficient sample preparation. Due to the relatively large effective injection volume of the in-tube SPME technique (30-45 mu L), on-column focusing was employed in order to achieve good chromatographic efficiency. Excellent sensitivity was achieved with very good method precision. For all carbamates studied, the RSD of retention time was between 0.5 and 0.8% under 4 mu L/min microgradient conditions. The RSD of peak area counts was between 1.5 and 4,6%, The detection limits for all carbamates studied were less than 0.3 mu g/L and, for carbaryl, just 0.02 mu g/L (20 ppt), Compared with the conventional in-tube SPME/LC method, the LODs were lowered for carbaryl, propham, methiocarb, promecarb, chlorpropham, and barban, by factors of 24, 45, 42, 81, 62, and 56, respectively. The optimized method was successfully applied to the analysis of carbamates in surface water samples.
引用
收藏
页码:2774 / 2779
页数:6
相关论文
共 50 条
  • [1] Array capillary in-tube solid-phase microextraction: A rapid preparation technique for water samples
    Yan, Xiaohui
    Wu, Dapeng
    Peng, Hong
    Ding, Kun
    Duan, Chunfeng
    Guan, Yafeng
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1244 : 69 - 76
  • [2] On-fibre solid-phase microextraction coupled to conventional liquid chromatography versus in-tube solid-phase microextraction coupled to capillary liquid chromatography for the screening analysis of triazines in water samples
    Chafer-Pericas, C.
    Herraez-Hernandez, R.
    Campins-Falco, P.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1125 (02) : 159 - 171
  • [3] In-tube solid-phase microextraction coupled to liquid chromatography (in-tube SPME/LC) analysis of nontricyclic antidepressants in human plasma
    Goncalves Silva, Bruno Jose
    Lancas, Fernando Mauro
    Costa Queiroz, Maria Eugenia
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 181 - 188
  • [4] Further investigation of array capillary in-tube solid-phase microextraction of trace organic pollutants in water samples
    Yan, Xiaohui
    Wu, Dapeng
    Meng, Hu
    Hao, Liang
    Ding, Kun
    Guan, Yafeng
    [J]. ANALYTICAL METHODS, 2014, 6 (03) : 750 - 757
  • [5] Fully automated in-tube solid-phase microextraction for liquid samples coupled to gas chromatography
    Daniel Globig
    Christian Weickhardt
    [J]. Analytical and Bioanalytical Chemistry, 2005, 381 : 656 - 659
  • [6] Fully automated in-tube solid-phase microextraction for liquid samples coupled to gas chromatography
    Globig, D
    Weickhardt, C
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (03) : 656 - 659
  • [7] Novel materials as capillary coatings for in-tube solid-phase microextraction for bioanalysis
    Grecco, Caroline Fernandes
    de Souza, Israel Donizeti
    Queiroz, Maria Eugenia Costa
    [J]. JOURNAL OF SEPARATION SCIENCE, 2021, 44 (08) : 1662 - 1693
  • [8] In-tube solid-phase microextraction-capillary liquid chromatography as a solution for the screening analysis of organophosphorus pesticides in untreated environmental water samples
    Chafer-Pericas, C.
    Herraez-Hernandez, R.
    Campins-Falco, P.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1141 (01) : 10 - 21
  • [9] Automated determination of rifampicin in plasma samples by in-tube solid-phase microextraction coupled with liquid chromatography
    Melo, L. P.
    Queiroz, R. H. C.
    Queiroz, M. E. C.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (24): : 2454 - 2458
  • [10] Analysis of Contact Traces of Cannabis by In-Tube Solid-Phase Microextraction Coupled to Nanoliquid Chromatography
    Jornet-Martinez, Neus
    Ortega-Sierra, Adrian
    Verdu-Andres, Jorge
    Herraez-Hernandez, Rosa
    Campins-Falco, Pilar
    [J]. MOLECULES, 2018, 23 (09):