Decreased complications but a distinctive fixation loosening mechanism of fully threaded headless cannulated screw fixation for femoral neck fractures in young adults

被引:24
|
作者
Sun, Hui [1 ]
Shu, Lin-Yuan [2 ]
Sherrier, Matthew C. [3 ]
Zhu, Yi [1 ]
Liu, Jing-Wen [1 ]
Zhang, Wei [1 ]
机构
[1] Shanghai Jiao Tong Univ Affiliated Peoples Hosp 6, Dept Orthopaed Surg, 600 YiShan Rd, Shanghai 200233, Peoples R China
[2] Shanghai Jiao Tong Univ Affiliated Peoples Hosp 6, Dept Emergency Med, 600 YiShan Rd, Shanghai 200233, Peoples R China
[3] Univ Pittsburgh, Dept Phys Med & Rehabil, Med Ctr, Pittsburgh, PA 15219 USA
关键词
Femoral neck fracture; Internal fixation; Fully threaded headless cannulated screws; Complication; Fixation failure;
D O I
10.1186/s13018-021-02335-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Despite being a commonly encountered injury in orthopedic practice, controversy surrounds the methods of optimal internal fixation for femoral neck fractures (FNF) in young patients. The objective of the present study is to compare complication rates and failure mechanisms for surgical fixation of FNF using fully threaded headless cannulated screws (FTHCS) versus partial threaded cannulated screws (PTS) in young adults. Methods A total of 75 patients (18-65 years old) with FNF were prospectively treated with close reduction and internal fixation using three parallel FTHCS and compared to a historical control case-matched group (75 patients) with FNF treated by PTS fixation. After 2 years follow-up, rates of fixation failure (including varus collapse, fracture displacement, and femoral neck shortening), nonunion, and avascular necrosis of the femoral head (ANFH) were compared between the two cohorts. The demographic, follow-up information, and radiological images were assessed by independent blinded investigators. Results Patient demographics and fracture patterns were similar in the two patient groups. The overall fixation failure rates were 8% (6/75) in the FTHCS cohort, which was significantly lower than the 25.3% (19/75) seen in the PTS group. Rates of nonunion and ANFH were significantly lower in the FTHCS group when compared to the PTS control group. When stratified by injury severity (high-energy vs. low-energy fractures), the rate of fixation failure was significant lower with the use of FTHCS when compared with PTS for high-energy fractures while there was no difference in the rates of nonunion or ANFH for high or low-energy fracture patterns. Unique to the FTHCS cohort was an atypical screw migration pattern with varus collapse (6/75, 8%). Conclusions The results show that FTHCS fixation could significantly reduce the complication rate of young patients with FNF, especially in high-energy fracture patterns (Garden III-IV, Pauwels III, or vertical of the neck axis (VN) angle >= 15 degrees). There was also confirmation that the modes of fixation loosening in the FTCHS group, including screw "medial migration" and superior cutout, were different from the screw withdrawal pattern seen in the PTS cohort.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
    Mutlu, Harun
    Mutlu, Serhat
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 271 - 271
  • [42] Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
    Gardner, A. W.
    Toh, M. Z.
    Yew, K. S. A.
    Lie, D. T. T.
    Chou, S. M.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (01) : 41 - 46
  • [43] Parallel and non-parallel cannulated screw fixation complications in femoral neck fractures: A systematic review and meta-analysis
    Lim, Eic Ju
    Kim, Beom-Su
    Kim, Chul-Ho
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (06)
  • [44] SUBCHONDRAL SCREW FIXATION FOR FEMORAL-NECK FRACTURES
    REHNBERG, L
    OLERUD, C
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (02): : 178 - 180
  • [45] What is the appropriate axial position in cannulated screw fixation for femoral neck fractures? A finite element analysis
    Dae-Kyung Kwak
    Yeji Lee
    Sung-Jae Lee
    Seunghun Lee
    Je-Hyun Yoo
    BMC Musculoskeletal Disorders, 26 (1)
  • [46] Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study
    Zhou, Lin
    Lin, Jiaming
    Huang, Anfei
    Gan, Weidong
    Zhai, Xu
    Sun, Kai
    Huang, Shiqing
    Li, Zhizhong
    CLINICAL BIOMECHANICS, 2020, 74 : 103 - 110
  • [47] High incidence of "in-out-in" posterosuperior screws after cannulated screw fixation of femoral neck fractures
    Yuan, Brandon J.
    Shamaa, Mohamad Tayseer
    Aibinder, William R.
    Parry, Joshua A.
    Cross, William W.
    Barlow, Jonathan D.
    Sems, Stephen A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08): : 1417 - 1420
  • [48] The Targon Femoral Neck hip screw versus cannulated screws for internal fixation of intracapsular fractures of the hip
    Griffin, X. L.
    Parsons, N.
    Achten, J.
    Costa, M. L.
    BONE & JOINT JOURNAL, 2014, 96B (05): : 652 - 657
  • [49] Robot-assisted Percutaneous Cannulated Screw Fixation of Femoral Neck Fractures: Preliminary Clinical Results
    Duan, Sheng-jun
    Liu, Hua-shui
    Wu, Wen-cheng
    Yang, Kun
    Zhang, Zhen
    Liu, Shi-dong
    ORTHOPAEDIC SURGERY, 2019, 11 (01) : 34 - 41
  • [50] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +