The Efficacy of Anti-vibration Gloves

被引:17
|
作者
Hewitt, Sue [1 ]
Dong, Ren [2 ]
McDowell, Tom [2 ]
Welcome, Daniel [2 ]
机构
[1] Hlth & Safety Execut, Harpur Hill SK17 9JN, Buxton, England
[2] NIOSH, Engn & Control Technol Branch, Hlth Effects Lab Div, Morgantown, WV 26505 USA
来源
ACOUSTICS AUSTRALIA | 2016年 / 44卷 / 01期
关键词
Anti-vibration gloves; Hand-arm vibration; Hand-arm vibration syndrome; Personal protective equipment; HAND-TRANSMITTED VIBRATION; 3 ORTHOGONAL DIRECTIONS; REDUCING GLOVES; ARM VIBRATION; PERFORMANCE; PALM;
D O I
10.1007/s40857-015-0040-5
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Anyone seeking to control the risks from vibration transmitted to the hands and arms may contemplate the use of anti-vibration gloves. To make an informed decision about any type of personal protective equipment, it is necessary to have performance data that allow the degree of protection to be estimated. The information provided with an anti-vibration glove may not be easy to understand without some background knowledge of how gloves are tested and does not provide any clear route for estimating likely protection. Some of the factors that influence the potential efficacy of an anti-vibration glove include how risks from hand-arm vibration exposure are assessed, how the standard test for a glove is carried out, the frequency range and direction of the vibration for which protection is sought, how much hand contact force or pressure is applied and the physical limitations due to glove material and construction. This paper reviews some of the background issues that are useful for potential purchasers of anti-vibration gloves. Ultimately, anti-vibration gloves cannot be relied on to provide sufficient and consistent protection to the wearer and before their use is contemplated all other available means of vibration control ought first to be implemented.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 50 条
  • [31] Assessing Increased Activities of the Forearm Muscles Due to Anti-Vibration Gloves: Construct Validity of a Refined Methodology
    Yao, Yumeng
    Rakheja, Subhash
    Lariviere, Christian
    Marcotte, Pierre
    HUMAN FACTORS, 2022, 64 (03) : 466 - 481
  • [32] MULTIMAT ANTI-VIBRATION MATERIAL
    不详
    MACHINERY AND PRODUCTION ENGINEERING, 1977, 131 (3380): : 301 - 301
  • [33] A method for assessing the effectiveness of anti-vibration gloves using biodynamic responses of the hand-arm system
    Dong, RG
    Rakheja, S
    McDowell, TW
    Welcome, DE
    Wu, JZ
    Warren, C
    Barkley, J
    Washington, B
    Schopper, AW
    JOURNAL OF SOUND AND VIBRATION, 2005, 282 (3-5) : 1101 - 1118
  • [34] Effects of hand-tool coupling conditions on the isolation effectiveness of air bladder anti-vibration gloves
    Dong, RG
    McDowell, TW
    Welcome, D
    Barkley, J
    Warren, C
    Washington, B
    JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2004, 23 (04): : 231 - 248
  • [35] ANTI-SEISMIC AND ANTI-VIBRATION DEVICES
    Bratu, Polidor
    ROMANIAN JOURNAL OF ACOUSTICS AND VIBRATION, 2010, 7 (02): : 70 - 70
  • [36] A SIMPLE ANTI-VIBRATION GALVANOMETER SUPPORT
    COATES, GE
    COATES, JF
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1945, 22 (08): : 153 - 154
  • [37] A MAGNETICALLY LEVITATED ANTI-VIBRATION MOUNT
    JONES, DI
    OWEN, RG
    IEEE TRANSACTIONS ON MAGNETICS, 1984, 20 (05) : 1687 - 1689
  • [38] ACTIVE HYDRAULIC ANTI-VIBRATION SYSTEMS
    FURMAN, FA
    RUSSIAN ENGINEERING JOURNAL-USSR, 1972, 52 (05): : 37 - &
  • [39] Correlations between biodynamic characteristics of human hand-arm system and the isolation effectiveness of anti-vibration gloves
    Dong, RG
    McDowell, TW
    Welcome, DE
    Smutz, WP
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2005, 35 (03) : 205 - 216
  • [40] Anti-vibration systems for safety and comfort
    Portal, Eric
    Schaffhauser, Luc
    ATZ worldwide, 2004, 106 (12) : 16 - 19