Three-dimensional dose verification using BANG gel: a clinical example

被引:15
|
作者
Scheib, SG [1 ]
Gianolini, S [1 ]
机构
[1] Gamma Knife Ctr Zurich, Klin Pk, CH-8027 Zurich, Switzerland
关键词
dosimetry; dose verification; BANG gel; radiosurgery; gamma knife;
D O I
10.3171/jns.2002.97.supplement_5.0582
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object The authors sought to demonstrate the possible value of three-dimensional dose verification by using gel dosimetry. Methods. In this study, commercially available BANG-25 Gy gel was used. This polymer gel is tissue equivalent and the relaxation rate (R2) measured using magnetic resonance (MR) imaging is proportional to the absorbed dose in the gel. A cylindrical container filled with BANG was mounted within an anthropomorphic head phantom and was handled using the same process as would be used for a patient undergoing gamma knife radiosurgery (GKS). An irregular target outline was constructed and a dose plan was created consisting of seven shots, three using the 8-mm and four using the 4-mm collimator helmet. The maximum dose specified was 25 Gy. A combination of several single spin-echo MR imaging sequences with different echo times was used to calculate the R2. The geometric resolution of the MR images was approximately I mm(3). To compare the measured dose distribution with the calculated one, isodoses were overlaid in three orthogonal planes by using specially designed analysis software. Conclusions. Comparisons of the measured and calculated relative dose distributions showed good overall agreement, with differences of less than 3 mm between measured and calculated isodoses. High resolution BANG gel dosimetry for GKS can be useful for the verification of clinical treatment plans, especially when multiple shots are involved. Further verifications will be done using additional imaging parameters and absolute dose calibrations to improve the method.
引用
收藏
页码:582 / 587
页数:6
相关论文
共 50 条
  • [1] Three-Dimensional Dose Verification Using Normoxic Polymer Gel Dosimeters for Tomotherapy
    Huang, T.
    Zhang, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [2] Three-dimensional dose verification of the clinical application of gamma knife stereotactic radiosurgery using polymer gel and MRI
    Papagiannis, P
    Karaiskos, P
    Kozicki, M
    Rosiak, JM
    Sakelliou, L
    Sandilos, P
    Seimenis, I
    Torrens, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (09): : 1979 - 1990
  • [3] Inclusion type radiochromic gel dosimeter for three-dimensional dose verification
    Usui, Shuji
    Yoshioka, Munenori
    Hayashi, Shin-ichiro
    Tominaga, Takahiro
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [4] Three-Dimensional Gel Dosimetry for Dose Volume Histogram Verification in Stereotactic Radiosurgery
    Semnicka, J.
    Novotny, J., Jr.
    Spevacek, V.
    Garcic, J.
    Steiner, M.
    Judas, L.
    [J]. RADIOSURGERY, VOL 7, 2010, 7 : 44 - 55
  • [5] Verification of three-dimensional IMRT dose distribution in the inhomogeneous media using a polymer-gel dosimeter
    Dvorak, P
    Spevacek, V
    Novotny, J
    Hrbacek, J
    Bogner, J
    Kroupa, B
    Georg, D
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S339 - S340
  • [6] Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters
    Ibbott, GS
    Maryanski, MJ
    Eastman, P
    Holcomb, SD
    Zhang, YS
    Avison, RG
    Sanders, M
    Gore, JC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05): : 1097 - 1103
  • [7] Three-dimensional dose verification for radiation therapy
    Guo, P.
    Adamovics, J.
    Oldham, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S710 - S711
  • [8] Three-Dimensional Dose Verification Using a Stacked Radiochromic Film Dosimeter
    Liu, K.
    Wang, Y.
    Dona, O.
    Adamovics, J.
    Wuu, C.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E865 - E865
  • [9] Three-dimensional BANG™ gel dosimetry in conformal carbon ion radiotherapy
    Ramm, U
    Weber, U
    Bock, M
    Krämer, M
    Bankamp, A
    Damrau, M
    Thilmann, C
    Bottcher, HD
    Schad, LR
    Kraft, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : N95 - N102
  • [10] Three-dimensional dose distribution from shielded cylindric high-dose-rate applicators with BANG polymer gel dosimetry
    Liu, L
    Maryanski, MJ
    Schulz, RJ
    Gore, JC
    Knisely, JP
    [J]. RADIOLOGY, 1996, 201 : 717 - 717