Three-dimensional BANG™ gel dosimetry in conformal carbon ion radiotherapy

被引:52
|
作者
Ramm, U
Weber, U
Bock, M
Krämer, M
Bankamp, A
Damrau, M
Thilmann, C
Bottcher, HD
Schad, LR
Kraft, G
机构
[1] Univ Frankfurt Klinikum, ZRad, Klin Strahlentherapie, D-60590 Frankfurt, Germany
[2] GSI, D-64291 Darmstadt, Germany
[3] Deutsch Krebsforschungszentrum, Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2000年 / 45卷 / 09期
关键词
D O I
10.1088/0031-9155/45/9/401
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study we applied BANG(TM) polymer-gel dosimetry using magnetic resonance imaging (MRI) to densely ionizing radiation such as carbon ion beams. BANGTM polymer gels were irradiated with a quadratic field of monoenergetic C-12 ions at different beam energies in the range of 135 MeV u(-1) to 410 MeV u(-1). They were irradiated at the radiotherapy facility of the GSI, Darmstadt, Germany. Our object was to examine the saturation effect for densely ionizing radiation that occurs at high values of linear energy transfer (LET). The examination yielded the first effectiveness values that will be discussed in the following sections. A solid sphere and a hollow sphere were both irradiated with a horizontal pencil beam from the raster scanning facility at energies of 268 MeV u(-1) (solid sphere) and 304 MeV u(-1) (hollow sphere) respectively. MR dosimetry measurements were compared with data from a planning system. As far as quality is concerned. there is good agreement between the measured dose distributions of both samples and the dose maps from the planning software. The measured MR signals cannot be converted into absolute dose, since the relative efficiency is still unknown for mixed radiation fields of primary carbon ions and it is known only to a limited extent for nuclear fragments with different energies from highly energetic photon radiation. Model calculations are in progress in order to facilitate conversions of measured MR signals into dose.
引用
收藏
页码:N95 / N102
页数:8
相关论文
共 50 条
  • [1] Validation of MR-based polymer gel dosimetry as a preclinical three-dimensional verification tool in conformal radiotherapy
    De Deene, Y
    De Wagter, C
    Van Duyse, B
    Derycke, S
    Mersseman, B
    De Gersem, W
    Voet, T
    Achten, E
    De Neve, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (01) : 116 - 125
  • [2] A Comparison of Three-dimensional Conformal Proton Radiotherapy, Three-Dimensional Conformal Photon Radiotherapy and Intensity Modulated Radiotherapy for Retroperitoneal Sarcomas
    Swanson, E. L.
    Slopsema, R.
    Louis, D.
    Paryani, N.
    Morris, C. G.
    Indelicato, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S612 - S612
  • [3] Three-dimensional conformal radiotherapy for esophageal carcinoma
    Wang, L.
    Han, C.
    Chi, Z.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S470 - S470
  • [4] Radiochromic gel dosemeter for three-dimensional dosimetry
    Bero, MA
    Gilboy, WB
    Glover, PM
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 433 - 435
  • [5] Intensity-modulated three-dimensional conformal radiotherapy
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 121 - 121
  • [6] Application of a spacer gel to optimize three-dimensional conformal and intensity modulated radiotherapy for prostate cancer
    Pinkawa, Michael
    Corral, Nuria Escobar
    Caffaro, Mariana
    Piroth, Marc D.
    Holy, Richard
    Djukic, Victoria
    Otto, Gundula
    Schoth, Felix
    Eble, Michael J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) : 436 - 441
  • [7] Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters
    Ibbott, GS
    Maryanski, MJ
    Eastman, P
    Holcomb, SD
    Zhang, YS
    Avison, RG
    Sanders, M
    Gore, JC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05): : 1097 - 1103
  • [8] Isolated plexiform neurofibroma: Treatment with three-dimensional conformal radiotherapy
    Robertson, TC
    Buck, DA
    Schmidt-Ullrich, R
    Powers, CN
    Reiter, ER
    [J]. LARYNGOSCOPE, 2004, 114 (07): : 1139 - 1142
  • [9] The advantages of three-dimensional conformal radiotherapy for treatment of childhood cancer
    Smitt, MC
    McPeak, EM
    Donaldson, SS
    [J]. RADIATION RESEARCH, 1998, 150 (05) : S170 - S177
  • [10] Conformal three-dimensional photon radiotherapy for paranasal sinus tumors
    Lohr, F
    Pirzkall, A
    Debus, J
    Rhein, B
    Höss, A
    Schlegel, W
    Wannenmacher, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2000, 56 (02) : 227 - 231