Nonparametric extraction of transient changes in neurotransmitter concentration from dynamic PET data

被引:14
|
作者
Constantinescu, Cristian C. [1 ]
Bouman, Charles
Morris, Evan D.
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 46907 USA
[2] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 46907 USA
[3] Indiana Univ Purdue Univ, Dept Biomed Engn, Indianapolis, IN 46202 USA
[4] Indiana Univ, Sch Med, Dept Radiol, Indianapolis, IN 46202 USA
关键词
dopamine; positron emission tomography; singular value decomposition;
D O I
10.1109/TMI.2006.891501
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We have developed a nonparametric approach to the analysis of dynamic positron emission tomography (PET) data for extracting temporal characteristics of the change in endogenous neurotransmitter concentration in the brain. An algebraic method based on singular value decomposition (SVD) was applied to simulated data under both rest (neurotransmitter at baseline) and activated (transient neurotransmitter release) conditions. The resulting signals are related to the integral of the change in free neurotransmitter concentration in the tissue. Therefore, a specially designed minimum mean-square error (MMSE) filter must be applied to the signals to recover the desired temporal pattern of neurotransmitter change. To test the method, we simulated sets of realistic time activity curves representing uptake of [11C]raclopride, a dopamine (DA) receptor antagonist, in brain regions, under baseline and dopamine-release conditions. Our tests considered two scenarios: 1) a spatially homogeneous pattern with all voxels in the activated state presenting an identical DA signal; 2) a spatially heterogeneous pattern in which different DA signals were contained in different families of voxels. In the first case, we demonstrated that the timing of a single DA peak can be accurately identified to within 1 min and that two distinct neurotransmitter peaks can be distinguished. In the second case, separate peaks of activation separated by as little as 5 min can be distinguished. A decrease in blood flow during activation could not account for our findings. We applied the method to human PET data acquired with [11C]raclopride in the presence of transiently elevated DA due to intravenous (IV) alcohol. Our results for an area of the nucleus accumbens-a region relevant to alcohol consumption-agreed with a model-based method for estimating the DA response. SVD-based analysis of dynamic PET data promises a completely noninvasive and model-independent technique for determining the dynamics of a neurotransmitter response to cognitive or pharmacological stimuli. Our results indicate that the method is robust enough for application to voxel-by-voxel data.
引用
收藏
页码:359 / 373
页数:15
相关论文
共 50 条
  • [41] A Nonlocal Averaging Technique for Kinetic Parameter Estimation from Dynamic PET Data
    Dutta, Joyita
    El Fakhri, Georges
    Leahy, Richard M.
    Li, Quanzheng
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3562 - 3566
  • [42] COMPUTATION OF VARIANCE IN COMPARTMENT MODEL PARAMETER ESTIMATES FROM DYNAMIC PET DATA
    Kamasak, Mustafa E.
    [J]. 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 646 - 649
  • [43] Generalized Algorithms for Direct Reconstruction of Parametric Images From Dynamic PET Data
    Wang, Guobao
    Qi, Jinyi
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) : 1717 - 1726
  • [44] DETERMINATION OF SQUEEZE-FILM DYNAMIC COEFFICIENTS FROM EXPERIMENTAL TRANSIENT DATA
    RAMLI, MD
    ROBERTS, JB
    ELLIS, J
    [J]. JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 1987, 109 (01): : 155 - 163
  • [45] Extraction of epileptogenic foci from PET and SPECT images by fuzzy modeling and data fusion
    Boussion, N
    Cinotti, L
    Barra, V
    Ryvlin, P
    Mauguiere, F
    [J]. NEUROIMAGE, 2003, 19 (03) : 645 - 654
  • [46] Automatic extraction of the heart volumes from dynamic FDG PET emission images for movement corrections
    Kivimäki, A
    Tohka, J
    Anttila, M
    Ruotsalainen, U
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S406 - S406
  • [47] Automatic Extraction of Myocardial Mass and Volume Using Parametric Images from Dynamic Nongated PET
    Harms, Hendrik Johannes
    Hansson, Nils Henrik Stubkjaer
    Tolbod, Lars Poulsen
    Kim, Won Yong
    Jakobsen, Steen
    Bouchelouche, Kirsten
    Wiggers, Henrik
    Frokiaer, Jorgen
    Sorensen, Jens
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (09) : 1382 - 1387
  • [48] Strategies for extraction of quantitative data from volumetric dynamic cardiac positron emission tomography data
    Huesman, RH
    Klein, GJ
    Reutter, BW
    Coxson, PG
    Botvinick, EH
    Budinger, TF
    [J]. CARDIOLOGY, 1997, 88 (01) : 54 - 61
  • [49] EXTRACTION OF MINERAL ABSORPTION FEATURES FROM HIGH-SPECTRAL-RESOLUTION DATA USING NONPARAMETRIC GEOSTATISTICAL TECHNIQUES
    VANDERMEER, F
    [J]. INTERNATIONAL JOURNAL OF REMOTE SENSING, 1994, 15 (11) : 2193 - 2214
  • [50] Automatic TAC extraction from dynamic cardiac PET imaging using iterative correlation from a population template
    Mateos-Perez, Jose M.
    Desco, Manuel
    Dae, Michael W.
    Garcia-Villalba, Carmen
    Cusso, Lorena
    Vaquero, Juan J.
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 111 (02) : 308 - 314