Disposable screen-printed biosensor for transcutaneous oxygen measurement

被引:4
|
作者
Lam, YZ [1 ]
Atkinson, J [1 ]
机构
[1] Univ Southampton, Sch Engn Sci, Thick Film Unit, Southampton SO17 1BJ, Hants, England
关键词
transcutaneous oxygen; screen-printing; amperometric;
D O I
10.1088/0957-0233/13/12/336
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A disposable transcutaneous oxygen sensor has been designed and fabricated in-house employing screen-printing methods so as to achieve cost-effective and reliable production. The oxygen sensing module of the device is based on the amperometric Clarke cell principle. A three-electrode configuration consisting of miniature gold working and counter-electrodes and a silver/silver chloride reference electrode is screen-printed onto alumina substrate resulting in approximately 15 mum thickness layers. A platinum heater element is integrated into the design to make transcutaneous measurements, typically at 44 degreesC. The performances of different screen-printed membrane materials have been evaluated in both hydrated and dry test conditions using cyclic voltammographs and static tests where the devices are subjected to different oxygen levels. All measurements are made by a fully automated computer-controlled gas rig.
引用
收藏
页码:2074 / 2081
页数:8
相关论文
共 50 条
  • [31] Amperometric bienzyme screen-printed biosensor for the determination of leucine
    Pratima Labroo
    Yue Cui
    [J]. Analytical and Bioanalytical Chemistry, 2014, 406 : 367 - 372
  • [32] Study on electrochemical biosensor based on screen-printed electrode
    Zou, Quan
    Cheng, Gong
    Zhang, Yu
    [J]. MODERN PHYSICS LETTERS B, 2018, 32 (34-36):
  • [33] Screen-printed disposable electrodes: Pharmaceutical applications and recent developments
    Mohamed, Heba M.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 82 : 1 - 11
  • [34] Screen-printed diamond electrode: A disposable sensitive electrochemical electrode
    Kondo, Takeshi
    Sakamoto, Hironori
    Kato, Takayoshi
    Horitani, Masaru
    Shitanda, Isao
    Itagaki, Masayuki
    Yuasa, Makoto
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (12) : 1546 - 1549
  • [35] Voltammetric determination of Rutin at Screen-Printed carbon disposable electrodes
    de Oliveira-Roberth, Aline
    Santos, Diego I. V.
    Cordeiro, Diogo D.
    Lino, Fernando M. de A.
    Bara, Maria T. F.
    Gil, Eric de S.
    [J]. CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (05): : 1609 - 1616
  • [36] Disposable screen-printed sensors for the electrochemical detection of TNT and DNT
    Caygill, J. Sarah
    Collyer, Stuart D.
    Holmes, Joanne L.
    Davis, Frank
    Higson, Seamus P. J.
    [J]. ANALYST, 2013, 138 (01) : 346 - 352
  • [37] Erratum to: Disposable screen-printed sensors for determination of Duloxetine Hydrochloride
    Nawal A Alarfaj
    Reda A Ammar
    Maha F El-Tohamy
    [J]. Chemistry Central Journal, 6
  • [38] Disposable screen-printed electrodes for the immunochemical detection of polychlorinated biphenyls
    DelCarlo, M
    Lionti, I
    Taccini, M
    Cagnini, A
    Mascini, M
    [J]. ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) : 189 - 197
  • [39] A high selective disposable biosensor based on screen-printed technique with two working electrodes for eliminating interference signals
    Chen, Ping
    Peng, Yong
    Hao, Yuanqiang
    Huang, Qiyu
    Liu, You-Nian
    Deng, Chunyan
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 : 589 - 593
  • [40] A Broad-Range Disposable Electrochemical Biosensor Based on Screen-Printed Carbon Electrodes for Detection of Human Noroviruses
    Wang, Nan
    Pan, Guiying
    Guan, Shimin
    Rong, Shaofeng
    Wang, Dapeng
    Gao, Zhiyong
    Tian, Peng
    Li, Qianqian
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10