Smartphone-Based Single-Camera Stereo-DIC System: Thermal Error Analysis and Design Recommendations

被引:3
|
作者
Yu, Liping [1 ]
Bekdullayev, Nurlat [1 ]
Lubineau, Gilles [1 ]
机构
[1] King Abdullah Univ Sci & Technol KAUST, Phys Sci & Engn Div PSE, COHMAS Lab, Thuwal 239556900, Saudi Arabia
关键词
Cameras; Strain; Mirrors; Optical sensors; Optical imaging; Adaptive optics; Temperature measurement; Stereo-digital image correlation; smartphone; thermal error;
D O I
10.1109/JSEN.2021.3054805
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Coupling a smartphone-based stereo-DIC system using a single smartphone and a 3D-printed four-mirror adapter has been recently proposed by the authors as a cost-effective and field-portable 3D displacements measurement tool. However, this system is found to be very sensitive to temperature variation inside the smartphone and the ambient temperature variation around the system, which further can introduce displacement and strain errors into the measured results. Interestingly, the image coordinate drifts of image points that are directly associated with these thermal errors cannot be well explained by the existing temperature-induced camera deformation models. To eliminate the large thermal errors and realize high-accuracy 3D deformation measurement, a comprehensive thermal error analysis is performed for the smartphone-based single-camera stereo-DIC system. The theoretical estimations based on the existing temperature-induced camera deformation model are compared with the experimental observations. Then, all the potential error sources that can introduce thermal errors in the smartphone-based single-camera stereo-DIC system are analyzed and discussed. Several comparison tests confirm that the thermal errors are caused by both the inner structural changes and the deformation from the adapter, and that the thermal errors from the adapter are much larger than those caused by the inner deformation inside the smartphone camera. Finally, a modified mirror adapter was fabricated and proven less sensitive to the temperature variation. This research is expected to explain all the potential thermal error sources in the smartphone-based single-camera stereo-DIC system and further contribute to the correction of the thermal errors and the optimal design of the adapter.
引用
收藏
页码:9567 / 9576
页数:10
相关论文
共 10 条
  • [1] Design and validation of a demand-oriented single-camera stereo-DIC system with a four-mirror adapter
    Luo, Haojian
    Yu, Liping
    Pan, Bing
    [J]. MEASUREMENT, 2021, 186
  • [2] Design and Validation of a Compact Bi-Prism- Based Single-Bilateral-Telecentric-Camera Stereo-DIC System
    Luo, Haojian
    Yu, Liping
    Pan, Bing
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [3] Prism-based single-camera system for stereo display
    Zhao, Yue
    Cui, Xiaoyu
    Wang, Zhiguo
    Chen, Hongsheng
    Fan, Heyu
    Wu, Teresa
    [J]. OPTICAL ENGINEERING, 2016, 55 (06)
  • [4] Low-cost, portable, robust and high-resolution single-camera stereo-DIC system and its application in high-temperature deformation measurements
    Chi, Yuxi
    Yu, Liping
    Pan, Bing
    [J]. OPTICS AND LASERS IN ENGINEERING, 2018, 104 : 141 - 148
  • [5] Single-camera 3D-DIC system based on a fiber bundle
    Tu, Han
    Gao, Zeren
    Bai, Chuanbiao
    Lan, Shihai
    Wang, Yaru
    Zhang, Qingchuan
    [J]. OPTICS AND LASERS IN ENGINEERING, 2021, 147
  • [6] Single-camera panoramic stereo system model based on skew ray tracing
    Sung, Chi-Kuei
    Lu, Chia-Hung
    [J]. OPTIK, 2012, 123 (07): : 594 - 603
  • [7] Design of illumination system using characterized illuminances for smartphone-based fundus camera
    Lee, Seung-Jae
    Yang, Kyung-Mo
    Lee, Keun-Bum
    Park, No-Cheol
    [J]. OPTICS AND LASERS IN ENGINEERING, 2023, 168
  • [8] SINGLE-CAMERA SYSTEM FOR MEASURING PAPER DEFORMATIONS BASED ON IMAGE ANALYSIS
    Pelczynski, Pawel
    Szewczyk, Wlodzimierz
    Bienkowska, Maria
    [J]. METROLOGY AND MEASUREMENT SYSTEMS, 2021, 28 (03) : 509 - 522
  • [9] The accuracy and utility of a low cost thermal camera and smartphone-based system to assess grapevine water status
    Petrie, Paul R.
    Wang, Yeniu
    Liu, Scarlett
    Lam, Stanley
    Whitty, Mark A.
    Skewes, Mark A.
    [J]. BIOSYSTEMS ENGINEERING, 2019, 179 : 126 - 139
  • [10] Bi-prism-based single-bilateral-telecentric-camera stereo-DIC for accurate underwater 3D deformation measurement: Implementation of a parametric model
    Luo, Haojian
    Yu, Liping
    Pan, Bing
    [J]. OPTICS AND LASERS IN ENGINEERING, 2023, 162