Design of illumination system using characterized illuminances for smartphone-based fundus camera

被引:1
|
作者
Lee, Seung-Jae [1 ,2 ]
Yang, Kyung-Mo [2 ]
Lee, Keun-Bum [2 ]
Park, No-Cheol [1 ]
机构
[1] Yonsei Univ, Dept Mech Engn, 50 Yonsei Ro, Seoul 03722, South Korea
[2] Samsung Elect Co Ltd, 129 Samsung Ro, Suwon 16677, Gyeonggi Do, South Korea
关键词
Smart-phone based fundus camera; Illumination system; Retinal illumination performance space; Retinal uniformity; Back-reflection suppression; OPTIMIZATION; PARAMETERS; TAGUCHI;
D O I
10.1016/j.optlaseng.2023.107664
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently, smartphone-based fundus camera (SBFC) research has been actively conducted in response to the need to expand medical infrastructure in underdeveloped countries and the increased telemedicine since the COVID-19 pandemic. Compared to the conventional table-top system, SBFCs have technical challenges that make it difficult to guarantee uniform illumination and avoid back-reflection because of the design constraints of minimizing the form factor and cost. This paper proposes a novel illumination design methodology using characterized illuminance to obtain high-quality fundus images for SBFCs. Key performance indicators (KPIs), such as retinal uniformity, back-reflection suppression, and optical efficiency, were defined to evaluate the performance of the illumination system. Each KPI was calculated using optical simulation software based on Monte-Carlo ray tracing and mapped into a normalized three-dimensional coordinate, the retinal illumination performance space (RIPS). In RIPS, the KPIs are combined into a single parameter Delta(RIPS), which is the quantitative difference evaluated as the Euclidean distance between the ideal and actual design point. A compact SBFC illumination system with five design variables was presented to verify the proposed methodology. The final design values at the minimum Delta(RIPS) were determined using the Taguchi method and response surface methodology. Finally, a working prototype was built, and fundus images were acquired by clinical testing under institutional review board approval. The fundus image had sufficient brightness and resolution to diagnose the lesion with a viewing angle of approximately 50 degrees in one shot.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Assessment of a smartphone-based camera for fundus imaging in animals
    Balland, Olivier
    Russo, Andrea
    Isard, Pierre-Francois
    Mathieson, Iona
    Semeraro, Francesco
    Dulaurent, Thomas
    [J]. VETERINARY OPHTHALMOLOGY, 2017, 20 (01) : 89 - 94
  • [2] Smartphone-based fundus imaging system
    Cong Jing
    Zu Ming-ming
    Li Hong-tao
    Cui Xiao-yu
    Chen Shuo
    Xi Peng
    [J]. CHINESE OPTICS, 2019, 12 (01): : 97 - 103
  • [3] Design and development of smartphone-based imaging platform using electroluminescence illumination
    Banik, Soumyabrata
    Melanthota, Sindhoora Kaniyala
    Dutta, Sibasish
    Mazumder, Nirmal
    [J]. RESULTS IN OPTICS, 2021, 3
  • [4] Evaluation of an offline, artificial intelligence system for referable glaucoma screening using a smartphone-based fundus camera: a prospective study
    Rao, Divya Parthasarathy
    Shroff, Sujani
    Savoy, Florian M.
    Shruthi, S.
    Hsu, Chao-Kai
    Negiloni, Kalpa
    Pradhan, Zia Sultan
    Jayasree, P., V
    Sivaraman, Anand
    Rao, Harsha L.
    [J]. EYE, 2024, 38 (06) : 1104 - 1111
  • [5] Evaluation of an offline, artificial intelligence system for referable glaucoma screening using a smartphone-based fundus camera: a prospective study
    Divya Parthasarathy Rao
    Sujani Shroff
    Florian M. Savoy
    Shruthi S
    Chao-Kai Hsu
    Kalpa Negiloni
    Zia Sultan Pradhan
    Jayasree P V
    Anand Sivaraman
    Harsha L. Rao
    [J]. Eye, 2024, 38 : 1104 - 1111
  • [6] An Implementation of Smartphone-based Driver Assistance System Using Front and Rear Camera
    Chang, Kyungwon
    Oh, Byung-Hun
    Hong, Kwang-Seok
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2014, : 282 - 283
  • [7] A smartphone-based portable fundus camera for retinal photography in infants with suspected nonaccidental trauma
    Solyman, Omar
    Elbid, Amgad A.
    Elborgy, Ebrahim S.
    Abushanab, Mokhtar M., I
    [J]. JOURNAL OF AAPOS, 2022, 26 (04): : 214 - 216
  • [8] Clinical validation of a smartphone-based handheld fundus camera for the evaluation of optic nerve head
    Titoneli, Carolina C.
    Filho, Marcio S.
    Lencione, Diego
    Vieira, Flavio Pascoal
    Stuchi, Jose Augusto
    Paula, Jayter S.
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2021, 84 (06) : 531 - 537
  • [9] Optical design and fabrication of a smartphone fundus camera
    Chen, Weilin
    Chang, Jun
    Zhao, Xuehui
    Liu, Sitong
    [J]. APPLIED OPTICS, 2021, 60 (05) : 1420 - 1427
  • [10] Design and Implementation of a Smartphone-Based Positioning System
    Yeh, Chun-Chao
    Lo, Yu-Ching
    Chang, Chin-Chun
    [J]. TRENDS IN APPLIED KNOWLEDGE-BASED SYSTEMS AND DATA SCIENCE, 2016, 9799 : 995 - 1006