Clinical validation of a smartphone-based handheld fundus camera for the evaluation of optic nerve head

被引:3
|
作者
Titoneli, Carolina C. [1 ]
Filho, Marcio S. [2 ]
Lencione, Diego [3 ]
Vieira, Flavio Pascoal [3 ]
Stuchi, Jose Augusto [3 ]
Paula, Jayter S. [1 ]
机构
[1] Univ Sao Paulo, Fac Med Ribeirao Preto, Ribeirao Preto, SP, Brazil
[2] Fundacao PIO XII, Barretos, SP, Brazil
[3] Phelcom Technol, Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Photography/instrumentation; Smartphone; Optic nerve; Telemedicine; GLOBAL PREVALENCE; VISION IMPAIRMENT; INTRAOBSERVER; AGREEMENT; BLINDNESS; DISTANCE; DISK;
D O I
10.5935/0004-2749.20210080
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the quality of retinal images captured with a smartphone-based, handheld fundus camera with that of retinal images captured with a commercial fundus camera and to analyze their agreement in determining the cup-to-disc ratio for a cohort of ophthalmological patients. Methods: A total of 50 patients from a secondary ophthalmic outpatient service center underwent a bilateral fundus examination under mydriasis with a smartphone-based, handheld fundus camera and with a commercial fundus camera (4 images/patient by each). Two experienced ophthalmologists evaluated all the fundus images and graded them on the Likert 1-5 scale for quality. Multivariate regression analyses was then performed to evaluate the factors associated with the image quality. Two masked ophthalmologists determined the vertical cup-to-disc ratio of each fundus image, and both the intraobserver (between devices) and interobserver agreement between them was calculated. Results: Ninety-eight images from 49 patients were processed in this study for their quality analysis. Ten images from five patients (four from commercial fundus camera and one from smartphone-based, handheld fundus camera) were not included in the analyses due to their extremely poor quality. The medians [interquartile interval] of the image quality were not significantly different between those from the smartphone-based, handheld fundus camera and from the commercial fundus camera (4 [4-5] versus 4 [3-4] respectively, p = 0.06); however, both the images captured with the commercial fundus camera and the presence of media opacity presented a significant negative correlation with the image quality. Both the intraobserver [intraclass correlation coefficient (ICC)=0.82, p<0.001 and 0.83, p<0.001, for examiners 1 and 2, respectively] and interobserver (ICC=0.70, p=0.001 and 0.81; p<0.001, for smartphone-based handheld fundus camera and commercial fundus camera, respectively) agreements were excellent and statistically significant. Conclusions: Our results thus indicate that the smartphone-based, handheld fundus camera yields an image quality similar to that from a commercial fundus camera, with significant agreement in the cup-to-disc ratios between them. In addition to the good outcomes recorded, the smartphone-based, handheld fundus camera offers the advantages of portability and low-cost to serve as an alternative for fundus documentation for future telemedicine approaches in medical interventions.
引用
收藏
页码:531 / 537
页数:7
相关论文
共 50 条
  • [1] Smartphone-based evaluation of the optic nerve head
    Pujari, Amar
    Mukhija, Ritika
    Chawla, Rohan
    Phuljhele, Swati
    Saxena, Rohit
    Sharma, Pradeep
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (11) : 1617 - 1618
  • [2] Undilated versus dilated monoscopic smartphone-based fundus photography for optic nerve head evaluation
    Maximilian W. M. Wintergerst
    Christian K. Brinkmann
    Frank G. Holz
    Robert P. Finger
    Scientific Reports, 8
  • [3] Undilated versus dilated monoscopic smartphone-based fundus photography for optic nerve head evaluation
    Wintergerst, Maximilian W. M.
    Brinkmann, Christian K.
    Holz, Frank G.
    Finger, Robert P.
    SCIENTIFIC REPORTS, 2018, 8
  • [4] Clinical utility of handheld fundus and smartphone-based camera for monitoring diabetic retinal diseases: a review study
    Naz, Huma
    Nijhawan, Rahul
    Ahuja, Neelu Jyothi
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [5] Smartphone-based optic nerve head evaluation: mydriasis is what makes the difference
    Wintergerst, Maximilian W. M.
    Brinkmann, Christian Karl
    Finger, Robert P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [6] Using a smartphone-based digital fundus camera for screening of retinal and optic nerve diseases in veterinary medicine: A preliminary investigation
    Sebbag, Lionel
    Ofri, Ron
    Arad, Dikla
    Handel, Karin W.
    Pe'er, Oren
    VETERINARY RECORD, 2024, 194 (09) : no
  • [7] Assessment of a smartphone-based camera for fundus imaging in animals
    Balland, Olivier
    Russo, Andrea
    Isard, Pierre-Francois
    Mathieson, Iona
    Semeraro, Francesco
    Dulaurent, Thomas
    VETERINARY OPHTHALMOLOGY, 2017, 20 (01) : 89 - 94
  • [8] Remote Screening for Optic Nerve Cupping Using Smartphone-based Nonmydriatic Fundus Photography
    LaMonica, Lauren C.
    Bhardwaj, Mahesh K.
    Hawley, Nicola L.
    Naseri, Take
    Reupena, Muagatutia S.
    Cooper, Michael L.
    Cotran, Paul R.
    Roh, Shiyoung
    Ramsey, David J.
    JOURNAL OF GLAUCOMA, 2021, 30 (01) : 58 - 60
  • [9] Evaluation of the SVOne: A Handheld, Smartphone-Based Autorefractor
    Ciuffreda, Kenneth J.
    Rosenfield, Mark
    OPTOMETRY AND VISION SCIENCE, 2015, 92 (12) : 1133 - 1139
  • [10] A New Smartphone-Based Optic Nerve Head Biometric for Verification and Change Detection
    Coleman, Kate
    Coleman, Jason
    Franco-Penya, Hector
    Hamroush, Fatima
    Murtagh, Patrick
    Fitzpatrick, Patricia
    Aiken, Mary
    Combes, Andrew
    Keegan, David
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (08):