Direct determination of glucose in serum by fluorimetry using a labeled enzyme

被引:39
|
作者
Sierra, JF [1 ]
Galban, J [1 ]
De Marcos, S [1 ]
Castillo, JR [1 ]
机构
[1] Univ Zaragoza, Fac Sci, Dept Analyt Chem, GEAS, Zaragoza 50009, Spain
关键词
fluorescence; glucose; labeled glucose oxidase; serum; fluorescein-5(6)-carboxamido-caproic acid ester;
D O I
10.1016/S0003-2670(00)00831-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper we propose the use of derivatized glucose oxidase (GOx) with fluorescein-5(6)-carboxamido-caproic acid ester (FS) for the direct fluorometric determination of glucose in blood serum. This method is based on the modification of the fluorescence of GOx-FS (lambda(excitation)=489 nm and lambda(emission)=520 nm) with the analyte concentration during its enzymatic reaction with the glucose. This makes a second enzymatic reaction unnecessary. The mechanism by which the change in the fluorescence of GOx-FS takes place is discussed and a mathematical equation which models the process is given. The derivatization and measurement conditions were optimized: in the optimum conditions GOx-FS is stable for at least 3 weeks, the detection limit obtained is 85 mg l(-1) and the precision 2.5% (n=9). The results were compared with those obtained by a commercial clinical analyzer and no systematic errors were observed. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 50 条
  • [41] Direct glucose determination in blood using a reagentless optical biosensor
    Sanz, Vanesa
    de Marcos, Susana
    Galban, Javier
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (12): : 2876 - 2883
  • [42] DETERMINATION OF CEREBRAL METABOLIC RATES INVIVO USING STABLE ISOTOPICALLY LABELED GLUCOSE
    NOVOTNY, EJ
    ROTHMAN, DL
    AVISON, MJ
    PETROFF, OAC
    LANTOS, G
    PRICHARD, JW
    SHULMAN, RG
    ANNALS OF NEUROLOGY, 1989, 26 (03) : 463 - 463
  • [43] Application of enzyme field-effect transistors for determination of glucose concentrations in blood serum
    Dzyadevich, Sergei V.
    Korpan, Yaroslav I.
    Arkhipova, Valentina N.
    Alesina, Marina Yu.
    Martelet, Claude
    El'Skaya, Anna V.
    Soldatkin, Alexey P.
    Biosensors and Bioelectronics, 1999, 14 (03): : 283 - 287
  • [44] Application of enzyme field-effect transistors for determination of glucose concentrations in blood serum
    Dzyadevich, SV
    Korpan, YI
    Arkhipova, VN
    Alesina, MY
    Martelet, C
    El'Skaya, AV
    Soldatkin, AP
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (03): : 283 - 287
  • [45] ENZYMATIC METHOD FOR DETERMINATION OF SERUM GLUCOSE USING CLINICARD SYSTEM
    DUNKA, LJ
    LADDEN, PJ
    LITTRELL, ME
    DURSO, CL
    BOSKO, JA
    CLINICAL CHEMISTRY, 1975, 21 (07) : 979 - 979
  • [46] DIRECT ENZYME-LINKED IMMUNOSORBENT-ASSAY THAT USES ENZYME-LABELED ANTIGEN FOR DETERMINATION OF IGM ANTIBODIES TO TOXOPLASMA
    VANLOON, AM
    HEESSEN, FWA
    VANDERLOGT, JTM
    VANDERVEEN, J
    ANTONIE VAN LEEUWENHOEK JOURNAL OF MICROBIOLOGY, 1983, 49 (06): : 615 - 616
  • [47] Direct lodimetric determination of glucose
    Voorhies, A
    Alvarado, AM
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1927, 19 (01): : 848 - 849
  • [48] Simultaneous Direct Determination of Magnolol and Honokiol by Second Order Derivative Synchronous Fluorimetry
    Yang Jun
    Yu De-Shun
    Liu Shao-Pu
    Tian Yi-Fu
    Mo Bin-Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (01) : 107 - 110
  • [49] Dual electrochemical determination of glucose and insulin using enzyme and ferrocene microcapsules
    Viswanathan, Subramanian
    Ho, Ja-an Annie
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06): : 1147 - 1153
  • [50] DETERMINATION OF GLUCOSE, UREA AND PENICILLIN USING ENZYME-PH-ELECTRODES
    NILSSON, H
    AKERLUND, AC
    MOSBACH, K
    BIOCHIMICA ET BIOPHYSICA ACTA, 1973, 320 (02) : 529 - 534