An on-line system for preconcentration and determination of lead in wine samples by FAAS

被引:87
|
作者
Lemos, VA
de la Guardia, M
Ferreira, SLC
机构
[1] Univ Estadual Sudoeste Bahia, Lab Quim Analit, BR-45200000 Jequie, BA, Brazil
[2] Univ Valencia, Dept Quim Analyt, Valencia, Spain
[3] Univ Fed Bahia, Grp Pesquisa Quim Analit, Inst Quim, BR-40170290 Salvador, BA, Brazil
关键词
lead; wine; FAAS; on-line;
D O I
10.1016/S0039-9140(02)00325-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection method has been developed for the direct determination of free available Pb(II) and total Pb content in wine samples. The method is based on the chemical sorption of Pb(11), from pH 7 buffered solutions, on a packed polyurethane foam column, modified by addition of 2-(2-benzothiazolylazo)-p-cresol (BTAC). After this step, lead was directly eluted with a stream of 0.1 mol l(-1) HCl into an air C2H2 flame in which lead was determined by atomic absorption spectrometry. Total lead was analyzed after sample digestion with nitric acid and hydrogen peroxide, being free available lead determined by direct sample on-line preconcentration and elution. The method provides a limit of detection (3sigma) of I mug l(-1) lead and relative standard deviation, which varies from 6 to 0.7% for lead concentration of 10 and 500 mug l(-1). Total content of lead in wine samples analyzed varied from 8 to 42 mug l(-1) being obtained free available values of Pb(II) under the limit of detection of the method. Recovery studies on natural wine samples, spicked with inorganic lead, evidenced the remaining capability of ligands, present in the wine, to avoid lead retention on the polyurethane foam loaded with BTAC. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:475 / 480
页数:6
相关论文
共 50 条
  • [21] On-line complexation/preconcentration system for the determination of lead in wine by inductively coupled plasma-atomic emission spectrometry with ultrasonic nebulization
    Wuilloud, Rodolfo G.
    Gonzalez, Alfredo H.
    Marchevsky, Eduardo J.
    Olsina, Roberto A.
    Martinez, Luis D.
    1600, AOAC International (84):
  • [22] On-line preconcentration system for determination of lead in water and sediment samples by flow injection-flame atomic absorption spectrometry
    Soylak, M
    Elci, L
    Akkaya, Y
    Dogan, M
    ANALYTICAL LETTERS, 2002, 35 (03) : 487 - 499
  • [23] Determination of Iron( II ) and Total Iron Using Flow Injection On-line Preconcentration with FAAS
    Xu, Guang-Ming
    Ye, Ying-Xue
    Yin, Xue-Feng
    Shen, Hong
    Ali, Akbar
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 2000, 21 (03): : 352 - 353
  • [24] Determination of iron(II) and total iron using flow injection on-line preconcentration with FAAS
    Xu, GM
    Ye, YX
    Yin, XF
    Shen, H
    Ali, A
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2000, 21 (03): : 350 - 353
  • [25] On-line preconcentration system for nickel determination in food samples by flame atomic absorption spectrometry
    Ferreira, SLC
    dos Santos, WNL
    Lemos, VA
    ANALYTICA CHIMICA ACTA, 2001, 445 (02) : 145 - 151
  • [26] On-line preconcentration system for cadmium determination in environmental samples by flame atomic absorption spectrometry
    Soylak, M
    Narin, I
    CHEMIA ANALITYCZNA, 2005, 50 (04): : 705 - 715
  • [27] An on-line separation and preconcentration system coupled with flame atomic absorption spectrometry for the determination of lead
    Dasbasi, Teslima
    Sacmaci, Serife
    Sahan, Serkan
    Ulgen, Ahmet
    Kartal, Senol
    ANALYTICAL METHODS, 2013, 5 (13) : 3307 - 3313
  • [28] Flow injection on-line preconcentration and flame AAS determination of copper, cadmium and lead in marine sediment samples
    Kartikeyan, S
    Vijayalekshmy, B
    Chandramouleeswaran, S
    Rao, TP
    Iyer, CSP
    ANALYTICAL LETTERS, 1997, 30 (05) : 1037 - 1050
  • [29] Application of silica gel organofunctionalized with 3(1-imidazolyl)propyl in an on-line preconcentration system for the determination of copper by FAAS
    da Silva, EL
    Martins, AO
    Valentini, A
    de Fávere, VT
    Carasek, E
    TALANTA, 2004, 64 (01) : 181 - 189
  • [30] FAAS determination of gold and palladium using an on-line separation and preconcentration system based on a high-selective chelating adsorbent
    Liu, P
    Wu, XZ
    Sun, QY
    Su, ZX
    Pu, QS
    ATOMIC SPECTROSCOPY, 2001, 22 (05) : 392 - 397