Automated quality assurance for silicon microstrip sensors of the CBM Silicon Tracking System

被引:3
|
作者
Larionov, P. [1 ]
机构
[1] Goethe Univ Frankfurt, D-60054 Frankfurt, Germany
来源
关键词
Si microstrip and pad detectors; Particle tracking detectors (Solid-state detectors); Heavy-ion detectors;
D O I
10.1088/1748-0221/11/01/C01033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Silicon Tracking System (STS) is the main tracking detector of the upcoming fixedtarget Compressed Baryonic Matter (CBM) experiment which aims to explore the phase diagram of the strongly interacting matter in a region of high net baryonic densities and moderate temperatures. The STS will be used for the reconstruction of tracks of charged particles and determination of their momenta. The system comprises 8 tracking stations located 30 cm downstream the target and will be mounted with 300 mu m thick double-sided silicon microstrip sensors in three different sizes. In this paper, the Quality Assurance (QA) procedures for the STS sensors are overviewed highlighting the automated QA testing procedure for a single strip defect identification.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Overview of the Silicon Tracking System for the CBM experiment
    Larionov, Pavel
    FAIRNESS 2014: FAIR NEXT GENERATION SCIENTISTS 2014, 2015, 599
  • [12] THE SILICON TRACKING SYSTEM OF THE CBM EXPERIMENT AT FAIR
    Lymanets, A.
    UKRAINIAN JOURNAL OF PHYSICS, 2019, 64 (07): : 607 - 612
  • [13] The silicon tracking system of the CBM experiment at FAIR
    Schmidt, H. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 (630-633): : 630 - 633
  • [14] Development of low noise radiation hard sensors and cables for the CBM Silicon Tracking System
    Chatterji, S.
    Singla, M.
    Lymanets, A.
    Mueller, W. F. J.
    Merkin, M.
    Heuser, J. M.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1065 - 1070
  • [15] A portable readout system for silicon microstrip sensors
    Marco-Hernandez, Ricardo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 207 - 209
  • [16] Results of irradiation quality assurance of CMS silicon microstrip detectors
    Furgeri, Alexander J.
    de Boer, W.
    Hartmann, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 264 - 267
  • [17] Characterization and quality control of CMS silicon microstrip sensors
    Nicoleta, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 144 - 147
  • [18] Advanced methods for the optical quality assurance of silicon sensors
    Lavrik, E.
    Panasenko, I
    Schmidt, H. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 922 : 336 - 344
  • [19] Functional characterization of modules for the Silicon Tracking System of the CBM experiment
    Rodriguez, A. Rodriguez
    Rodriguez, O. Maragoto
    Lehnert, J.
    Toia, A.
    Teklishyn, M.
    Lymanets, A.
    Garces, D. Rodriguez
    Heuser, J. M.
    Schmidt, C. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1058
  • [20] A Portable Readout System for Microstrip Silicon Sensors (ALIBAVA)
    Marco-Hernandez, Ricardo
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2476 - 2483