Non-invasive Monitoring of Pulmonary Artery Pressure at the Bedside

被引:0
|
作者
Proenca, M. [1 ,2 ]
Braun, F. [1 ,2 ]
Muntane, E. [1 ]
Sola, J. [1 ]
Adler, A. [3 ]
Lemay, M. [1 ]
Thiran, J-Ph. [2 ,4 ,5 ]
Rimoldi, S. F. [6 ]
机构
[1] CSEM, Neuchatel, Switzerland
[2] Ecole Polytech Fed Lausanne, Lausanne, Switzerland
[3] Carleton Univ, Ottawa, ON, Canada
[4] Univ Hosp Ctr CHUV, Lausanne, Switzerland
[5] Univ Lausanne UNIL, Lausanne, Switzerland
[6] Univ Hosp, Inselspital Bern, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
EIT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Current solutions for the monitoring of pulmonary artery pressure (PAP) in patients suffering from pulmonary hypertension are limited to invasive means. Noninvasive alternatives, such as Doppler echocardiography, are incompatible with continuous monitoring due to their dependency on qualified personnel to perform the measurements. In the present study, a novel non-invasive and unsupervised approach based on the use of electrical impedance tomography (EIT) is presented. The approach was evaluated in three healthy subjects undergoing hypoxia-induced variations in PAP. A timing parameter physiologically linked to the PAP via the so-called pulse wave velocity principle - was automatically extracted from the EIT data. Reference systolic PAP estimates were obtained by echocardiography. Strong correlation scores (r is an element of [0.844, 0.990]) were found between the EIT-derived parameter and the reference PAP, thereby suggesting the validity of the proposed approach. If confirmed in larger datasets, these findings could open the way for a new branch of fully non-invasive hemodynamic monitors for patients with pulmonary hypertension.
引用
收藏
页码:4236 / 4239
页数:4
相关论文
共 50 条
  • [21] Non-invasive monitoring of pulmonary artery pressure from timing information by EIT: experimental evaluation during induced hypoxia
    Proenca, Martin
    Braun, Fabian
    Sola, Josep
    Adler, Andy
    Lemay, Mathieu
    Thiran, Jean-Philippe
    Rimoldi, Stefano F.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (06) : 713 - 726
  • [22] NON-INVASIVE MEASUREMENT OF PULMONARY-ARTERY PRESSURE USING PULSED DOPPLER ECHOCARDIOGRAPHY
    FOULT, JM
    BLANCHARD, D
    BONAN, R
    BOURASSA, MG
    WATERS, DD
    GUERMONPREZ, JL
    DAVID, PR
    THEROUX, P
    CIRCULATION, 1980, 62 (04) : 99 - 99
  • [23] Non-invasive assessment of effect of exercise on Pulmonary artery systolic pressure in healthy subjects
    Khan, A. A.
    EUROPEAN HEART JOURNAL, 2015, 36 : 962 - 962
  • [24] Non-invasive monitoring of the dynamic compliance in the carotid artery
    Hutten, H
    Monif, M
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 642 - 644
  • [25] Non-Invasive Bedside Assessment of Central Venous Pressure: Scanning into the Future
    Rizkallah, Jacques
    Jack, Megan
    Saeed, Mahwash
    Shafer, Leigh Anne
    Vo, Minh
    Tam, James
    PLOS ONE, 2014, 9 (10):
  • [26] INVASIVE OR NON-INVASIVE MONITORING
    HUGENHOL.PG
    HEIKKILA, J
    HAGEMEIJ.F
    ARNTZENI.AC
    POOL, J
    PALADINO, D
    CIRCULATION, 1972, 46 (04) : 75 - &
  • [27] Performance of continuous non-invasive blood pressure monitoring
    Soliveres, J.
    Balaguer, J.
    Higueras, R.
    Armero, R.
    Solaz, C.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 56 - 56
  • [28] Monckeberg sclerosis - Non-invasive blood pressure monitoring
    Tepel, M
    INTERNIST, 1997, 38 (04): : 365 - 365
  • [29] ON THE CONTINUOUS NON-INVASIVE MONITORING OF BLOOD-PRESSURE
    SPORTICHE, M
    JARDIN, F
    BOUROKBA, A
    MARGAIRAZ, A
    AGRESSOLOGIE, 1980, 21 : 163 - 164
  • [30] FONTOGRAM - NON-INVASIVE INTRACRANIAL-PRESSURE MONITORING
    BADA, HS
    SALMON, JH
    HAJJAR, WM
    PEDIATRIC RESEARCH, 1977, 11 (04) : 560 - 560