Chemical imaging of human teeth by a time-resolved Raman spectrometer based on a CMOS single-photon avalanche diode line sensor

被引:17
|
作者
Kekkonen, Jere [1 ]
Finnila, Mikko A. J. [2 ]
Heikkila, Jarkko [3 ]
Anttonen, Vuokko [3 ,4 ,5 ]
Nissinen, Ilkka [1 ]
机构
[1] Univ Oulu, Circuits & Syst Res Unit, Oulu 90014, Finland
[2] Univ Oulu, Res Unit Med Imaging Phys & Technol, SF-90220 Oulu, Finland
[3] Univ Oulu, Dept Cariol Endodontol & Pediat Dent, SF-90220 Oulu, Finland
[4] Oulu Univ Hosp, Med Res Ctr, Oulu 90220, Finland
[5] Univ Oulu, SF-90220 Oulu, Finland
基金
芬兰科学院;
关键词
FLUORESCENCE SUPPRESSION; SPECTROSCOPY; ENAMEL; DENTIN;
D O I
10.1039/c9an01136f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Raman spectroscopy is a powerful analytical tool to be used in many biomedical applications and could be potentially translated into clinical work. The challenge of Raman spectroscopy in biomedical applications is the high inherent fluorescence of biological samples. One promising method to suppress the fluorescence background is to use pulsed lasers and time-gated detectors but the complexity of time-gated systems has hindered their widespread usage. We present here chemical imaging of human teeth by means of a new kind of compact and practical fluorescence-suppressed Raman spectrometer based on a time-resolved 16 x 256 CMOS single-photon avalanche diode (SPAD) line sensor with an integrated 256-channel 3-bit on-chip time-to-digital converter. The chemical images were constructed by utilizing a simple unsupervised machine learning algorithm (k-means clustering). The high quality of Raman spectra measured with the time-resolved CMOS SPAD-based Raman spectrometer was verified by comparing the spectra to those collected with a commercial conventional continuous wave (CW) Raman spectrometer. The spectra measured by using the time-resolved CMOS SPAD-based Raman spectrometer had 4.4-8.8 times higher signal to peak-to-peak noise ratio values than the spectra from the CW Raman spectrometer when the same radiant exposure (similar to 300 J mm(-2)) was used with both spectrometers. This paper shows in practice the potential of time-resolved CMOS SPAD-based Raman spectroscopy in the field of biomedicine and we expect that the presented technology could pave the way for the development of new kind of compact and practical fluorescence-suppressed Raman spectrometers to be used both in biomedical research and clinical settings.
引用
收藏
页码:6089 / 6097
页数:9
相关论文
共 50 条
  • [31] Time-Resolved Diffuse Optical Spectroscopy up to 1700 nm by Means of a Time-Gated InGaAs/InP Single-Photon Avalanche Diode
    Bargigia, Ilaria
    Tosi, Alberto
    Shehata, Andrea Bahgat
    Della Frera, Adrian
    Farina, Andrea
    Bassi, Andrea
    Taroni, Paola
    Dalla Mora, Alberto
    Zappa, Franco
    Cubeddu, Rinaldo
    Pifferi, Antonio
    APPLIED SPECTROSCOPY, 2012, 66 (08) : 944 - 950
  • [32] Time-resolved diffuse optical spectroscopy up to 1700 nm using a time-gated InGaAs/InP Single-Photon Avalanche Diode
    Bargigia, I.
    Tosi, A.
    Bahgat Shehata, A.
    Della Frera, A.
    Farina, A.
    Bassi, A.
    Taroni, P.
    Dalla Mora, A.
    Zappa, F.
    Pifferi, A.
    NOVEL BIOPHOTONIC TECHNIQUES AND APPLICATIONS, 2011, 8090
  • [33] Characterization of a time-resolved non-contact scanning diffuse optical imaging system exploiting fast-gated single-photon avalanche diode detection
    Di Sieno, Laura
    Wabnitz, Heidrun
    Pifferi, Antonio
    Mazurenka, Mikhail
    Hoshi, Yoko
    Dalla Mora, Alberto
    Contini, Davide
    Boso, Gianluca
    Becker, Wolfgang
    Martelli, Fabrizio
    Tosi, Alberto
    Macdonald, Rainer
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (03):
  • [34] A Time-Resolved, Low-Noise Single-Photon Image Sensor Fabricated in Deep-Submicron CMOS Technology
    Gersbach, Marek
    Maruyama, Yuki
    Trimananda, Rahmadi
    Fishburn, Matt W.
    Stoppa, David
    Richardson, Justin A.
    Walker, Richard
    Henderson, Robert
    Charbon, Edoardo
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2012, 47 (06) : 1394 - 1407
  • [35] Near infrared single-photon imaging based on compressive sensing with a sinusoidally gated InGaAs/InP single-photon avalanche diode
    Hagihara, H.
    Namekata, N.
    Yokota, K.
    Inoue, S.
    ADVANCED OPTICAL TECHNIQUES FOR QUANTUM INFORMATION, SENSING, AND METROLOGY, 2020, 11295
  • [36] InGaAs/InP single-photon avalanche diode operated in gated mode for time-resolved diffuse optical spectroscopy up to 1700 nm
    Bargigia, I.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2012, 35 (05): : 75 - 80
  • [37] Time-resolved diffuse optical tomography using fast-gated single-photon avalanche diodes
    Puszka, Agathe
    Di Sieno, Laura
    Dalla Mora, Alberto
    Pifferi, Antonio
    Contini, Davide
    Boso, Gianluca
    Tosi, Alberto
    Herve, Lionel
    Planat-Chretien, Anne
    Koenig, Anne
    Dinten, Jean-Marc
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (08): : 1351 - 1365
  • [38] A Single-Photon Avalanche Diode in 90-nm CMOS Imaging Technology With 44% Photon Detection Efficiency at 690 nm
    Webster, Eric A. G.
    Richardson, Justin A.
    Grant, Lindsay A.
    Renshaw, David
    Henderson, Robert K.
    IEEE ELECTRON DEVICE LETTERS, 2012, 33 (05) : 694 - 696
  • [39] Monolithic SPAD Arrays for High-Performance, Time-Resolved Single-Photon Imaging
    Bruschini, Claudio
    Burri, Samuel
    Lindner, Scott
    Ulku, Arin C.
    Zhang, Chao
    Antolovic, I. Michel
    Wolf, Martin
    Charbon, Edoardo
    2018 INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS (OMN), 2018, : 183 - 184
  • [40] Toward video-rate compressive spontaneous Raman imaging via single-photon avalanche diode arrays
    Gentner, Clemence
    Burri, Samuel
    Charbon, Edoardo
    Bruschini, Claudio
    DE Aguiar, Hilton b.
    OPTICS LETTERS, 2024, 49 (22) : 6573 - 6576