New Equation for Optimal Insulation Dependency on the Climate for Office Buildings

被引:2
|
作者
Ahmed, Kaiser [1 ,2 ]
Kurnitski, Jarek [1 ,3 ]
机构
[1] Aalto Univ, Sch Engn, Dept Civil Engn, POB 12100, FI-00076 Espoo, Finland
[2] Granlund Oy, POB 59, FI-00701 Helsinki, Finland
[3] Tallinn Univ Technol, Smart City Ctr Excellence, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
基金
欧盟地平线“2020”;
关键词
conductance; climate correction; economic insulation thickness; NZEB office building; THERMAL INSULATION; THICKNESS; DESIGN; WALLS; ZONES;
D O I
10.3390/en14020321
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The comparison of building energy efficiency in different climates is a growing issue. Unique structural solutions will not ensure the same energy use, but the differences also remain if cost-optimal solutions are applied. This study developed a new equation for the assessment of building envelope optimal insulation in different climates for office buildings. The developed method suggests determining actual degree days from simulated heating energy need and the thermal conductance of a building, avoiding in such a way the use of a base temperature. The method was tested in four climates and validated against cost-optimal solutions solved with optimization. The accuracy of the method was assessed with sensitivity analyses of key parameters such as window-to-wall ratios (WWRs), window g-values, costs of heating, and electricity. These results showed that the existing square root equation overestimated the climate difference effect so that the calculation from the cold climate U-value resulted in less insulation than cost-optimal in warmer climates. Parametric analyses revealed that the power value of 0.2 remarkably improved the accuracy as well as performance worked well in all cases and can be recommended as a default value. Sensitivity analyses with a broad range of energy costs and window parameters revealed that the developed equation resulted in maximum 5% underestimation and maximum 7% overestimation of an average area-weighted optimal U-value of building envelope in another climate. The developed method allows objectively to compare optimal insulation of the building envelope in different climates. The method is easy to apply for energy performance comparison of similar buildings in different climates and also for energy performance requirements comparison.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Buildings - National Academies to build new office
    不详
    CIVIL ENGINEERING, 1999, 69 (06): : 27 - 27
  • [32] Thermal comfort enhancement of office buildings located under warm and humid climate through phase change material and insulation coupled with natural ventilation
    Arumugam, Pappu
    Ramalingam, Velraj
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2024, 63
  • [33] Adapting buildings to climate change by using the optimal thickness of thermal insulation for external walls: The case of Spain (2025-2055)
    Las-Heras-Casas, Jesus
    Lopez-Ochoa, Luis M.
    Olasolo-Alonso, Pablo
    Lopez-Gonzalez, Luis M.
    JOURNAL OF CLEANER PRODUCTION, 2025, 490
  • [34] Optimal insulation thickness in historic buildings with a heat pump as an energy source
    Orzechowski, T.
    Orzechowski, M.
    INTERNATIONAL CONFERENCE ON THE SUSTAINABLE ENERGY AND ENVIRONMENTAL DEVELOPMENT, 2019, 214
  • [35] Evaluating optimal control of active insulation and HVAC systems in residential buildings
    Sepehri, Amin
    Pavlak, Gregory S.
    ENERGY AND BUILDINGS, 2023, 281
  • [36] Structural Equation Model of Occupant Satisfaction for Evaluating the Performance of Office Buildings
    Tekce, Isilay
    Ergen, Esin
    Artan, Deniz
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (10) : 8759 - 8784
  • [37] Structural Equation Model of Occupant Satisfaction for Evaluating the Performance of Office Buildings
    Isilay Tekce
    Esin Ergen
    Deniz Artan
    Arabian Journal for Science and Engineering, 2020, 45 : 8759 - 8784
  • [38] Energy saving with passive climate control methods in Spanish office buildings
    Orosa, Jose A.
    Oliveira, Armando C.
    ENERGY AND BUILDINGS, 2009, 41 (08) : 823 - 828
  • [39] Predicting thermal comfort in office buildings in a Brazilian temperate and humid climate
    Rupp, Ricardo Forgiarini
    Ghisi, Enedir
    ENERGY AND BUILDINGS, 2017, 144 : 152 - 166
  • [40] Passive climate control in Spanish office buildings for long periods of time
    Orosa, J. A.
    Baalina, A.
    BUILDING AND ENVIRONMENT, 2008, 43 (12) : 2005 - 2012