Temperature Effect on Insulation Resistance of Generator Stator Bar Affected by Water Ingress

被引:0
|
作者
Petit, Andre [1 ]
机构
[1] Elect France, DTG, Generator Diag Dept, Grenoble, France
关键词
generator; stator bar; insulation resistance; water ingress;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For water-cooled stator bar of power generator, leaks of water at the copper strand brazing location will reduce dramatically its insulation resistance. Therefore, the insulation resistance measurement is an important and simple test to perform in the periodic maintenance program. The temperature has an important effect on the insulation resistance. To correctly trend the insulation resistance of the winding, a correction factor has to be applied. This paper describes experimental data performed on both dry and wet epoxy-mica insulation from bars removed from an operating generator. The results are compared with different correction models. They show an important difference of the temperature coefficient between the dry and wet bar.
引用
收藏
页码:515 / 518
页数:4
相关论文
共 50 条
  • [21] Experience on the periodic wet bar diagnosis of water-cooled generator stator windings
    Kim, Hee-Soo
    Bae, Yong-Chae
    [J]. BALTICA VIII: LIFE MANAGEMENT AND MAINTENANCE FOR POWER PLANTS, VOL 2, 2010, 265 : 253 - 269
  • [22] Insulation resistance measurements versus temperature made on aged stator bars and coils
    Zhu, H.
    [J]. 2007 ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING EXPO, 2007, : 215 - 218
  • [23] Study of aging characteristics of generator stator insulation based on temperature spectrum of dielectric dissipation factor
    Ma, XQ
    Ma, XW
    You, B
    Lu, WS
    Xie, HK
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 294 - 297
  • [24] Influence of Main Insulation Thermal Aging on Stator Temperature Field in Large Turbo-generator
    Li, Wei-li
    Wu, Zhen-xing
    Huo, Fei-yang
    [J]. MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 7505 - +
  • [26] Generator temperature rise calculation with direct water cooling in the stator winding
    Kalmykov, I.
    García, A.
    Borgna, H.
    [J]. International Journal on Hydropower and Dams, 2001, 8 (03): : 92 - 95
  • [27] Study on anti-corona technique at the ends of stator bar specimen in the multi-stress aging test for large generator stator winding insulation
    Song, Jiancheng
    Yue, Bo
    Xie, Hengkun
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2000, 15 (03): : 1 - 5
  • [28] The temperature distribution of the stator bar in the evaporative cooling system of the hydro-generator on flow blocked
    Liu Feihui
    Ruan Lin
    Gu Guobiao
    Tian Xindong
    [J]. ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 589 - 591
  • [29] Calculation of the electrical field constraint and the potential breakdown risk in partially humid high voltage generator stator bar insulation
    Schlupp, P.
    Vizireanu, D.
    Ducreux, J. P.
    [J]. CONFERENCE RECORD OF THE 2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 2008, : 276 - 279
  • [30] Study on the Effect of Different Internal Corona Protection on Electrical Properties of Generator Stator Bar
    Hu, Chunxiu
    Yuan, Xiaohong
    He, Xin
    Zhang, Xiaohong
    [J]. ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 196 - +