Disposable electrochemical biosensor for amperometric measurement of β-hydroxybutyrate and total cholesterol

被引:0
|
作者
Li, Huaqing
Wang, Li
Rao, Nenggao
Cui, Dafu
Cai, Xinxia [1 ]
机构
[1] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100080, Peoples R China
关键词
amperometric; beta-hydroxybutyrate; total cholesterol; ferricyanide; platinum black;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new type of disposable thin-film amperometric biosensor has been developed for measurement of beta-hydroxybutyrate and total cholesterol in serum. The biosensor consists of two plain gold electrodes mounted on a Polyethylene terephthalate (PET) substrate. The reagent solution contains bienzymes (cholesterol oxidase and cholesterol esterase for total cholesterol, beta-hydroxybutyrate dehydrogenase and diaphorase for beta-hydroxybutyrate respectively) with mediator (ferricyanide) were absorption at the surface of electrodes coated by electrodepositing platinum black. The presence of the mediator lowers the applied potential and eliminates the interference from other oxidizable species enhancing the sensitivity and selectivity of the biosensor without modifying the dynamic parameters of the response. The enzymes stably retains in the matrices of platinum black film improving the performance of the mediated sensor. The linearity is observed in the concentration range from 10 x 10(-4) to 10 x 10(-2) mM and 10 x 10(-4) mM to 4.99 x 10(-3) mM with sensitivity of 1.958 mu A/mM and 2.447 mu A/mM respectively. The optimized biosensor exhibits excellent reproducibility and stability retaining more than 90% of its original activity over a period of one month. The simple operation of the biosensor mass-produced at low cost is expected to find clinical application and homecare.
引用
收藏
页码:305 / 308
页数:4
相关论文
共 50 条
  • [1] Disposable Electrochemical Biosensor for Amperometric Measurement of β-hydroxybutyrate and Total Cholesterol
    Huaqing Li Li Wang Nenggao Rao Dafu Cui Xinxia Cai State Key Laboratory of Transducer TechnologyInstitute of ElectronicsChinese Academy of SciencesBeijing China Graduate School of Chinese Academy of ScienceBeijing China
    稀有金属材料与工程, 2006, (S3) : 305 - 308
  • [2] A disposable amperometric biosensor for determining total cholesterol in whole blood
    Fang, Cheng
    He, Jishan
    Chen, Zhencheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02): : 545 - 550
  • [3] Development of disposable amperometric cholesterol biosensor
    Wang, Xiaohao
    Tang, Fei
    Xu, Xiaowen
    Chen, Zhencheng
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 321 - 323
  • [4] Development of Disposable Amperometric Cholesterol Biosensor
    Xiaohao Wang Fei Tang Xiaowen Xu Zhencheng Chen State Key Laboratory of Precision Measurement Technology and InstrumentsTsinghua UniversityBeijing China
    稀有金属材料与工程, 2006, (S3) : 321 - 323
  • [5] FABRICATION AND CHARACTERIZATION OF A SCREEN-PRINTED, DISPOSABLE, AMPEROMETRIC CHOLESTEROL BIOSENSOR
    GILMARTIN, MAT
    HART, JP
    ANALYST, 1994, 119 (11) : 2331 - 2336
  • [6] Development of disposable lipid biosensor for the determination of total cholesterol
    Shih, Wei-Chung
    Yang, Mei-Chun
    Lin, Meng Shan
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (06): : 1679 - 1684
  • [7] Development of a disposable amperometric biosensor for salicylate based on a plastic electrochemical microcell
    Carvalhal, R. F.
    Machado, D. S.
    Mendes, R. K.
    Almeida, A. L. J.
    Moreira, N. H.
    Piazetta, M. H. O.
    Gobbi, A. L.
    Kubota, L. T.
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (10): : 2200 - 2204
  • [8] The fabrication and optimization of the disposable amperometric biosensor
    Tu, YF
    Fu, ZQ
    Chen, HY
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 80 (02) : 101 - 105
  • [9] A disposable reagentless screen-printed amperometric biosensor for the measurement of alcohol in beverages
    Sprules, SD
    Hartley, IC
    Wedge, R
    Hart, JP
    Pittson, R
    ANALYTICA CHIMICA ACTA, 1996, 329 (03) : 215 - 221
  • [10] Mathematical Modelling of a Non-enzymatic Amperometric Electrochemical Biosensor for Cholesterol
    Goyal, Arpit
    Bairagi, Pallab Kumar
    Verma, Nishith
    ELECTROANALYSIS, 2020, 32 (06) : 1251 - 1262