Validation of a finite element model of the thoracolumbar spine to study instrumentation level variations in early onset scoliosis correction

被引:8
|
作者
Roth, Alex K. [2 ]
Beheshtiha, Alireza Sh. [1 ]
Meer, Ronald van der [1 ]
Willems, Paul C. [2 ]
Arts, Jacobus J. [1 ,2 ]
Ito, Keita [1 ]
Rietbergen, Bert van [1 ,2 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Orthopaed Biomech, Dolech 2, NL-5612 AZ Eindhoven, Netherlands
[2] Maastricht Univ, Med Ctr, Res Sch CAPHRI, Dept Orthopaed Surg, P Debyelaan 25, NL-6229 HX Maastricht, Netherlands
关键词
LUMBAR MOTION SEGMENT; CALIBRATION METHOD; LUQUE TROLLEY; GROWTH; MANAGEMENT; DISC; RECONSTRUCTION; VERTEBRAE; RANGE;
D O I
10.1016/j.jmbbm.2021.104360
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Growth-guidance constructs are an alternative to growing rods for the surgical treatment of early onset scoliosis (EOS). Constructs containing ultra-high molecular weight polyethylene (UHMWPE) sublaminar tape have been proposed as an improvement to the traditional Luque trolley. Ideally, a certain minimum number of levels is instrumented, thus offering the best balance between providing adequate spinal fixation and minimizing surgical exposure and spinal mobility reduction. The objective of the current study was to validate a parametric FE model of the thoracolumbar spine including its ability to predict the biomechanical effects of varying the number of levels instrumented with UHMWPE sublaminar tape in a growth-guidance construct for EOS correction. In a first step, the material properties of the L4-L5 segment in the model were calibrated relative to literature data. Next, whole thoracolumbar spine behavior was verified relative to literature data as well. Subsequently, rods, screws, and sublaminar tape were implemented in the model and a simulation of a previously performed in vitro experiment, in which the range of motion (ROM) of porcine spine segments was measured for different tape configurations, was performed. Good agreement between in vitro and FE-results was found for the changes in ROM before and after instrumentation. Good agreement for changes in ROM was obtained when varying the number of instrumented levels as well, indicating that the model can be a useful tool to evaluate the effects of construct composition variations. The present study was limited by the fact that only normal spine curvatures were analyzed and the fact that results of porcine spine experiments were compared to results of human FE models. Nevertheless, the good agreement in results, even at a detailed level, supports the idea that the model can ultimately be used as a pre-operative planning tool to evaluate different construct designs. The FE model of the thoracolumbar spine was successfully validated and was able to capture the biomechanical effect of construct component variations.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Instrumentation for correction and fixation of scoliosis in fibrous dysplasia of the thoracolumbar spine
    Janus G.J.M.
    Engelbert R.H.H.
    Pruijs J.E.H.
    [J]. European Spine Journal, 1998, 7 (3) : 260 - 262
  • [2] Porcine spine finite element model: a complementary tool to experimental scoliosis fusionless instrumentation
    Bahe Hachem
    Carl-Eric Aubin
    Stefan Parent
    [J]. European Spine Journal, 2017, 26 : 1610 - 1617
  • [3] Porcine spine finite element model: a complementary tool to experimental scoliosis fusionless instrumentation
    Hachem, Bahe
    Aubin, Carl-Eric
    Parent, Stefan
    [J]. EUROPEAN SPINE JOURNAL, 2017, 26 (06) : 1610 - 1617
  • [4] Development and validation of lumbar spine finite element model
    Wiczenbach, Tomasz
    Pachocki, Lukasz
    Daszkiewicz, Karol
    Luczkiewicz, Piotr
    Witkowski, Wojciech
    [J]. PEERJ, 2023, 11
  • [5] Prediction of deformity correction by pedicle screw instrumentation in thoracolumbar scoliosis surgery - (Computer simulation study)
    Kiriyama, Y
    Yamazaki, N
    Nagura, T
    Matsumoto, M
    Chiba, K
    Toyama, Y
    [J]. JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2005, 48 (04) : 577 - 585
  • [6] Clinically relevant finite element technique based protocol to evaluate growing rods for early onset scoliosis correction
    Shekouhi, Niloufar
    Dick, David
    Baechle, Maxwell William
    Kaeley, Dilpreet Kaur
    Goel, Vijay K.
    Serhan, Hassan
    Rawlinson, Jeremy
    Shaw, Derek
    [J]. JOR SPINE, 2020, 3 (03):
  • [7] Validation of a clinical finite element model of the human lumbosacral spine
    Guan, Yabo
    Yoganandan, Narayan
    Zhang, Jiangyue
    Pintar, Frank A.
    Cusick, Joesph F.
    Wolfla, Christopher E.
    Maiman, Dennis J.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (08) : 633 - 641
  • [8] Validation of a clinical finite element model of the human lumbosacral spine
    Yabo Guan
    Narayan Yoganandan
    Jiangyue Zhang
    Frank A. Pintar
    Joesph F. Cusick
    Christopher E. Wolfla
    Dennis J. Maiman
    [J]. Medical and Biological Engineering and Computing, 2006, 44 : 633 - 641
  • [9] Improvement and validation of a female finite element model of the cervical spine
    Silva, Afonso J. C.
    de Sousa, Ricardo J. Alves
    Fernandes, Fabio A. O.
    Ptak, Mariusz
    Dymek, Mateusz
    Parente, Marco P. L.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 142
  • [10] Kinematic and biomechanical responses of the spine to distraction surgery in children with early onset scoliosis: A 3-D finite element analysis
    Pei, Baoqing
    Lu, Da
    Wu, Xueqing
    Xu, Yangyang
    Ma, Chenghao
    Wu, Shuqin
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10